background image

©York Survey Supply Centre 2015

Ref:.. \operat98\instructions 15\36027.qxp 05-01-15

Suunto Tandem

Combination Compass/Clinometer

Two Precision Instruments in One!

Congratulations on your choice of the Suunto Tandem. The Suunto

Tandem is all you need for both slope/height measurements and 

compass bearings. It is a liquid-filled precision compass and clinometer

in one compact aluminium housing that is easy to use and rugged

enough to protect against impact, corrosion and water. This top quality

precision instrument combines precision accuracy with fast and easy

one-hand operation.

The pocket-size construction renders the Suunto Tandem most suitable

for every type of work. Its unique shape makes it comfortable to hold in

your hand. The optics of the Tandem can be adjusted to make the 

reading easier. The clinometer scale is in degrees and percent (0 - 90°,

0 - 150%) while the compass scale is azimuth (0 - 360° with reverse

scale). Both the clinometer and the compass are graduated in 1°/1% 

increments and each is individually calibrated. The two edges at 90°

angle make contact measurements possible, for example, when 

installing and positioning a satellite antenna.

ADJUSTING OPTICS

The optics of the Tandem can be adjusted

by turning the eyepiece with your fingers

as shown in Figure 1. Adjust the eyepiece

so that both the hairline and the scale are

sharp and the eyepiece slot settles in a

vertical position in the bearing compass

and in a horizontal position in the 

clinometer.

Fig.1. Adjusting optics

CLEANING THE TANDEM

In the case humidity or dirt develop 

inside the Tandem, it can be cleaned by

removing the detachable eyepiece. The

eyepiece can be removed by rotating it

counter-clockwise (Fig. 2). Rinse with

clean water, allow to dry and carefully 

reassemble the eyepiece.

Caution:

Do not use detergents or 

solvents of any kind as they might cause

damage to the capsules.

Fig. 2. Removing the eyepiece

CONTACT MEASURING

The Tandem can be used

for aligning satellite dish

antennae or for other

types of contact 

measuring. The clinometer

incorporates two different

contact edges (see Fig. 3)

which enable the 

measurement to be made

compared to the horizontal

or vertical plane. The scale

(0 - 90 - 0 degrees) can be

used in contact measuring

and it gives the angle of

the surface compared to

the contact plane.

Fig. 3. Edges for contact

measurement

BEARING COMPASS

Construction

The bearing compass is designed to combine extreme accuracy with

ease and speed of operation. The card is supported by a jewel bearing

and is immersed in a dampening fluid, giving vibrationless, smooth

movement. The compass has been given permanent antistatic 

treatment.

Inclination - Balancing

The compass card is balanced to correspond to the area within which

the compass is used. When using the compass elsewhere (e.g. on trips

abroad) the change of the vertical magnetic field could make the 

compass card dip and this may cause difficulties in taking the bearing.

The balancing zone (see Fig. 4), if other than 1, is indicated on the

back of the instrument below the serial number - contact York Survey

Supply Centre for details.

Fig. 4. The balancing zones

Declination

The compass reads magnetic north, which differs from true north by the

amount of the local declination which is printed on your map. In order to

lay out on a map a bearing obtained with the compass, the plus or

minus declination for the locality in question must be added to or 

subtracted from the compass bearing.

Deviation

Iron and steel objects close to the compass, like a wristwatch or steel-

rimmed spectacles, may cause deviation. Whenever possible, remove

such objects to a safe distance. Large structures like buildings, 

reinforced concrete quays etc. will cause deviation at some distance. A

reverse sighting from the opposite end of the target line will show up

any deviation present.

Operation

With both eyes open, aim the compass so that the hairline is 

superimposed on the target, when viewed through the lens. The main

scale (large numbers) gives the bearing from your position to the 

target, the small numbers give a reverse bearing from the target to your

position. This feature is of great assistance when calculating a precise

position.

Use the left or the right eye as preferred. With

both eyes open, an optical illusion makes the

hairline appear to continue above the instrument

frame, superimposed on the target. This improves

reading accuracy and speed.

Because of an eye condition called heterophoria,

the reading accuracy of some users may be 

impaired. Check for this as follows:

Take a reading with both eyes open and then

close the free eye. If the reading does not change

appreciably there is no disalignment of the eye

axes, and both eyes can be kept open. Should

there be a difference in the readings, keep the

other eye closed and sight halfway above the 

instrument body. The hairline now rises above 

the instrument body and is seen against the 

target (Fig. 5).

Fig. 5. The hairline is seen against the target

The instrument can also be used for triangulation (see Fig. 6). The

bearings obtained from the main scale are 0° against the hill and 64°

against the curve of the road, or 180° and 244° on the reverse scale.

Your own location is indicated by the intersection point of these two

lines. When performing very accurate positioning tasks, the bearings

obtained have to be corrected for local declination.

Fig. 6. Triangulation

The co-tangent table at the back of the Tandem can be utilised for 

distance calculations, and especially for locating position in cases

where two landmarks are visible at a narrow angle. This procedure 

is also illustrated in Fig. 6.

The angle between the curve of the road and the oil derrick is 15°. A

line is drawn at a 90° angle to the 64° bearing line from the curve of the

road toward the oil derrick bearing line. the distance, as measured on

the chart, is 1.6km (1 mile). Then your position is cot 15° x 1.6km (cot

15° x 1 mile = 3.7 miles) along the corrected bearing line of 64°.

CLINOMETER

Construction

The scale card is supported by a jewel bearing assembly and all 

moving parts are immersed in a damping liquid inside a high strength,

hermetically sealed plastic container. The liquid dampens all undue

scale vibrations and permits a smooth, shockless movement of the

scale card.

Instructions for Use

Readings are usually taken with the right eye. Owing to differences in

the keenness of the sight of the eyes and because of personal 

preferences, the use of the left eye is sometimes easier. It is of prime

importance that both eyes are kept open. the supporting hand must not

obstruct the vision of the other eye.

The instrument is held in front of the

reading eye so that the scale can be

read through the eyepiece and the

round side window faces to the left. The

instrument is aimed at the object by 

raising or lowering it until the horizontal

hairline is sighted against the point to be

measured. The position of the hairline

now on the scale is the reading. Owing

to an optical illusion, the hairline 

(cross-hair) seems to continue outside

the housing and is thus easily observed

against the sighted object (Fig. 7).

Fig. 7. The hairline indicates the reading

The left-hand scale angle gives the

slope angle in degrees from the 

horizontal plane at eye level. The right-hand scale gives the height 

of the point of sight from the same horizontal eye level, and it is 

expressed in percent of the horizontal distance. The following example

illustrates the procedure.

The task is to measure the height of a pillar at a distance of 25m (82ft)

on level ground (Fig. 8).

Fig. 8. Measuring height of a pillar

The instrument is tilted so that the hairline is seen against the pillar-top

(apex). The reading obtained wil be 48% (ca. 25½°). As the distance is

25m (82ft), the height of the pillar is 48 / 100 x 25 = ca. 12m (48 / 100 x

82 = ca. 39ft). To this must be added the eye’s height from the ground,

e.g. 1.6m (5½ft). Their sum is 13.6m (44½ft), the height of the pillar.

In very exact measurements, and particularly on sloping ground, two

readings are taken: one to the top, the other to the base of the pillar.

When the pillar base is below eye level, the percentages obtained are

added. The total height is the sum percentage of the horizontal 

distance. For example (Fig. 9), if the apex reading is 41% and the

ground reading is 13%, the total height of the pillar, measured from a

distance of 25m (82ft), is (41+ 13) / 100 x 25m = 54 / 100 x 25m = ca.

13.5m [(41 + 13) / 100 x 82ft = 54 / 100 x 82ft = ca. 44½ft].

Fig. 9. Taking two readings

When the pillar base is above eye level, the base reading is subtracted

from the apex reading, and the total height is the difference percentage

of the horizontal distance. For example (Fig. 10), if the apex reading is

64% and the base reading 14%, the total height is (64 - 14) / 100 x 25m

= 50 / 100 x 25m = 12.5m [(64 - 14) / 100 x 82ft = 50 / 100 x 82ft =

41ft]. When calculations are made mentally, it is advisable to use

measuring distances of 50, 100 or 200 ft, for the sake of simplicity

Fig. 10. Pillar above eye level

Reviews:

Related manuals for Suunto Tandem