03
6
-
2
150
2
-003-
A
-1105
4
2
Unit
a
ry Products Group
GUIDE SPECIFICATIONS
GENERAL
Units sh
a
ll be
ma
nu
fa
ctured by
Y
or
k
Intern
a
tion
a
l Unit
a
ry
Products Group in
a
n I
S
O 9001 certi
f
ied
fa
cility.
Y
or
k
's
S
unline
2
000
TM
units
a
re convertible sin
g
le p
a
c
kag
e-
units.
A
lthou
g
h the units
a
re pri
ma
rily desi
g
ned
f
or curb
m
ountin
g
on
a
roo
f
, they c
a
n
a
lso be sl
a
b-
m
ounted
a
t
g
round
level or set on steel be
am
s
a
bove
a
f
inished roo
f
. Coolin
g
only, coolin
g
w
ith
ga
s he
a
t
a
nd coolin
g
w
ith electric he
a
t
m
odels
a
re
a
v
a
il
a
ble
w
ith
a
w
ide v
a
riety o
f
fa
ctory-
m
ounted
options
a
nd
f
ield-inst
a
lled
a
ccessories to
mak
e the
m
suit
a
ble
f
or
a
l
m
ost every
a
pplic
a
tion.
A
ll units
a
re sel
f
-cont
a
ined
a
nd
a
sse
m
bled on
f
ull peri
m
eter b
a
se r
a
ils
w
ith holes in the
f
our
corners
f
or overhe
a
d ri
gg
in
g
. Every unit is co
m
pletely piped,
w
ired, ch
a
r
g
ed
a
nd tested
a
t the
fa
ctory to si
m
pli
f
y the
f
ield
inst
a
ll
a
tion
a
nd to provide ye
a
rs o
f
depend
a
ble oper
a
tion.
A
ll
m
odels (includin
g
those
w
ith
a
n econo
m
i
z
er)
a
re suit
a
ble
f
or
either botto
m
or hori
z
ont
a
l duct connections. Models
w
ith
po
w
er exh
a
ust
a
re suit
a
ble
f
or botto
m
duct connections only.
For botto
m
duct, re
m
ove the sheet
m
et
a
l p
a
nels
f
ro
m
the
supply
a
nd return
a
ir openin
g
s throu
g
h the b
a
se o
f
the unit.
For hori
z
ont
a
l duct, re
m
ove the supply
a
nd return
a
ir p
a
nels
on the re
a
r o
f
the unit.
A
ll non-
S
croll co
m
pressors include cr
a
n
k
c
a
se he
a
ters
a
nd
a
ll
co
m
pressors h
a
ve intern
a
l pressure relie
f
. Every re
f
ri
g
er
a
nt
circuit includes
a
li
q
uid line
f
ilter-drier,
a
disch
a
r
g
e line hi
g
h
pressure s
w
itch
a
nd
a
suction line
w
ith
a
f
ree
z
est
a
t
a
nd lo
w
pressure/loss o
f
ch
a
r
g
e s
w
itch.The unit control circuit
includes
a
7
5
VA
tr
a
ns
f
or
m
er,
a
2
4-volt circuit bre
ak
er
a
nd
a
rel
a
y bo
a
rd
w
ith
a
co
m
pressor loc
k
out circuit,
a
ter
m
in
a
l strip
f
or ther
m
ost
a
t
w
irin
g
, plus
a
n
a
ddition
a
l set o
f
pin connectors
to si
m
pli
f
y the inter
fa
ce o
f
a
ddition
a
l
f
ield controls.
A
ll units
h
a
ve lon
g
l
a
stin
g
po
w
der p
a
int c
a
binets
w
ith 1000 hour s
a
lt
spr
a
y test
a
pprov
a
l under
AS
TMB11
7
procedures.
A
ll
m
odels
a
re C
SA
listed.
A
ll
m
odels include
a
1-ye
a
r li
m
ited
wa
rr
a
nty
on the co
m
plete unit. Co
m
pressors
a
nd electric he
a
ter ele-
m
ents c
a
rry
a
5-ye
a
r
wa
rr
a
nty.
A
lu
m
ini
z
ed steel
a
nd
S
t
a
inless
steel tubul
a
r he
a
t exch
a
n
g
ers c
a
rry
a
10-ye
a
r
wa
rr
a
nty.
DESCRIPTION
Units sh
a
ll be
fa
ctory-
a
sse
m
bled, sin
g
le p
a
c
kag
ed, Electric
Coolin
g
/G
a
s He
a
t, Electric Coolin
g
/Option
a
l Electric He
a
t
a
nd desi
g
ned
f
or outdoor
m
ounted inst
a
ll
a
tion.
The 3 thru 5 ton units sh
a
ll h
a
ve
m
ini
m
u
m
S
EER r
a
tin
g
s o
f
10.0
a
nd the
6
ton units sh
a
ll h
a
ve
m
ini
m
u
m
EER r
a
tin
g
s o
f
9.0. They sh
a
ll h
a
ve built-in
f
ield convertible duct connections
f
or do
w
n disch
a
r
g
e supply/return or hori
z
ont
a
l disch
a
r
g
e sup-
ply/return,
a
nd be
a
v
a
il
a
ble
w
ith
fa
ctory inst
a
lled options or
f
ield inst
a
lled
a
ccessories. The units sh
a
ll be
fa
ctory
w
ired,
piped, ch
a
r
g
ed
w
ith R-
22
re
f
ri
g
er
a
nt
a
nd
fa
ctory tested prior
to ship
m
ent.
A
ll unit
w
irin
g
sh
a
ll be both nu
m
bered
a
nd color
coded.
A
ll units the coolin
g
per
f
or
ma
nce sh
a
ll be r
a
ted in
a
ccord
a
nce
w
ith DOE
a
nd
A
RI test procedures. Units sh
a
ll be
C
SA
listed, cl
a
ssi
f
ied to
A
N
S
I Z
2
1.4
7
, UL 1995/C
SA
No.
2
3
6
st
a
nd
a
rds.
UNIT CABINET
Unit c
a
binet sh
a
ll be constructed o
f
G90
ga
lv
a
ni
z
ed steel,
w
ith exterior sur
fa
ces co
a
ted
w
ith
a
non-ch
a
l
k
in
g
, po
w
dered
p
a
int
f
inish, certi
f
ied
a
t 1000 hours s
a
lt spr
a
y test per
AS
TMB11
7
st
a
nd
a
rds. Indoor blo
w
er section sh
a
ll be insu-
l
a
ted
w
ith
a
m
ini
m
u
m
1/
2”
thic
k
insul
a
tion, co
a
ted on the
a
ir-
side.
A
lu
m
inu
m
f
oil
fa
ced insul
a
tion sh
a
ll be used in the
f
urn
a
ce co
m
p
a
rt
m
ent
a
nd be
fa
stened
w
ith rid
g
ed
fa
steners
to prevent insul
a
tion
f
ro
m
enterin
g
the
a
ir stre
am
. C
a
binet
p
a
nels sh
a
ll be
“
l
a
r
g
e
”
si
z
e, e
a
sily re
m
ov
a
ble
f
or servicin
g
a
nd
ma
inten
a
nce. Full peri
m
eter b
a
se r
a
ils sh
a
ll be provided
to
a
ssure reli
a
ble tr
a
nsit o
f
e
q
uip
m
ent, overhe
a
d ri
gg
in
g
a
nd
proper se
a
lin
g
on roo
f
curb
a
pplic
a
tions. Dispos
a
ble 1"
f
ilters
sh
a
ll be
f
urnished
a
nd be
a
ccessible throu
g
h
a
re
m
ov
a
ble
a
ccess door, se
a
led
a
irti
g
ht. Units
f
ilter tr
a
c
k
sh
a
ll be
desi
g
ned to
a
cco
mm
od
a
te either 1
”
or
2”
f
ilters. F
a
n per
f
or-
ma
nce
m
e
a
surin
g
ports sh
a
ll be provided on the outside o
f
the c
a
binet to
a
llo
w
a
ccur
a
te
a
ir
m
e
a
sure
m
ents o
f
ev
a
por
a
tor
fa
n per
f
or
ma
nce
w
ithout re
m
ovin
g
p
a
nels or cre
a
tin
g
a
ir by-
p
a
ss o
f
the coils. Condens
a
te p
a
n sh
a
ll be intern
a
lly sloped
a
nd con
f
or
m
to
AS
HR
A
E
62
-89 sel
f
-dr
a
inin
g
st
a
nd
a
rds. Con-
dens
a
te connection sh
a
ll be
a
m
ini
m
u
m
o
f
3/4
”
I.D.
f
e
ma
le
a
nd be
a
rid
g
ed
m
ount connection.
INDOOR (EVAPORATOR) FAN ASSEMBLY
The indoor
fa
n sh
a
ll be direct drive,
m
ulti-speed, or
a
fa
ctory
inst
a
lled belt drive
a
sse
m
bly th
a
t includes
a
n
a
djust
a
ble pitch
m
otor pulley.
J
ob site selected (B.H.P.) br
ak
e horsepo
w
er sh
a
ll
not exceed the
m
otors n
am
epl
a
te horsepo
w
er r
a
tin
g
, plus the
service
fa
ctor. Units sh
a
ll be desi
g
ned not to oper
a
te
a
bove
service
fa
ctor. F
a
n
w
heel sh
a
ll be double-inlet type
w
ith
f
or-
wa
rd-curved bl
a
des, dyn
am
ic
a
lly b
a
l
a
nced to oper
a
te
s
m
oothly throu
g
hout the entire r
a
n
g
e o
f
oper
a
tion.
A
ir
f
lo
w
desi
g
n sh
a
ll be const
a
nt
a
ir volu
m
e. Be
a
rin
g
s sh
a
ll be se
a
led
a
nd per
ma
nently lubric
a
ted
f
or lon
g
er li
f
e
a
nd no
ma
inten
a
nce.
OUTDOOR (CONDENSER) FAN ASSEMBLY
The outdoor
fa
n sh
a
ll be o
f
the direct-driven propeller type,
disch
a
r
g
e
a
ir vertic
a
lly, h
a
ve
a
lu
m
inu
m
bl
a
des riveted to
a
corrosion resist
a
nt steel spider br
a
c
k
et
a
nd sh
a
ll be dyn
am
i-
c
a
lly b
a
l
a
nced
f
or s
m
ooth oper
a
tion. The outdoor
fa
n
m
otor
sh
a
ll be tot
a
lly enclosed
w
ith per
ma
nently lubric
a
ted be
a
r-
in
g
s, intern
a
lly protected
aga
inst overlo
a
d conditions
a
nd
st
ag
ed independently.
REFRIGERANT COMPONENTS
Co
m
pressor:
a
.
S
h
a
ll be intern
a
lly protected
w
ith intern
a
l hi
g
h-pres-
sure relie
f
a
nd over te
m
per
a
ture protection.
b.
S
h
a
ll h
a
ve intern
a
l sprin
g
isol
a
tion
a
nd sound
m
u
f
-
f
lin
g
to
m
ini
m
i
z
e vibr
a
tion
a
nd noise,
a
nd be exter-
n
a
lly isol
a
ted on
a
dedic
a
ted, independent
m
ountin
g
.
Coils:
a
.
Ev
a
por
a
tor
a
nd condenser coils sh
a
ll h
a
ve
a
lu
m
i-
nu
m
pl
a
te
f
ins
m
ech
a
nic
a
lly bonded to se
am
less