DESCRIPTION

YORK Sunline 2000 Heat Pumps are convertible single
package units with a common cabinet and common roof curb
for the 3, 4 and 5 ton sizes. The units were designed for
residential and light commercial applications. They can easily
be installed on a roof curb, slab, roof jack or frame.

All units are self--contained and assembled on rigid full
perimeter base rails allowing for 3--way fork lift access and
overhead rigging. Every unit is completely charged, wired,
piped and tested at the factory to provide for a quick and easy
field installation.

The units are available with supplemental electric heaters as
field--installed accessories.

Both down and side discharge airflows are available without
having to swap panels. The installer simply removes the duct
covers for the desired configuration. Economizers may be
used on either side or down discharge applications with no
modifications required.

All models include a 1--year limited warranty on the complete
unit. Compressors and electric heater elements each carry an
additional 4--year warranty.

FEATURES

CONTROLS -- These heat pumps utilize a unique time--
temperature defrost circuit which adjusts the time between
defrost cycles based on the outdoor temperature to provide
optimal comfort control and ensure reliable operation. The
ambient--modified, time--temperature defrost control extends the
time below 35

°

F and shortens the time above 35

°

F. The nominal

defrost times are field adjustable to 50, 80 and 110 minutes. The
defrost time is initiated and terminated by a liquid line control with
a 10 minute override limit built into the defrost control.

COMMON FOOTPRINT/COMMON CABINET -- The 3, 4 and
5 ton units all share the exact same cabinet -- and therefore the
same roof curb. You now have the flexibility of setting one curb
and, after the internal load has been determined, placing the
proper tonnage unit on that curb.

HIGH EFFICIENCY -- All units have a minimum SEER of 10, a
COP of 3.0 (high) and 2.0 (low) and an HSPF as high as 7.3.
These efficiencies exceed all legislated minimum levels and
provide low operating costs.

CONVERTIBLE AIRFLOW DESIGN -- Both the side and
bottom duct openings are covered when they leave the factory.
If a side supply/side return is desired, you simply remove the
two side duct covers from the outside of the unit and discard
them. If a bottom supply/return is desired, you simply remove
the two bottom duct covers and discard them. No panel cutting
or swapping is required! Convertible airflow design allows
maximum field flexibility and minimum inventory.

FACTORY--INSTALLED OPTIONS -- Economizers can be
installed at the factory. They are shipped installed and wired. The
outdoor air hood needs only to be field assembled and installed.

Adjustable belt--drive blowers are available on most models
from the factory for complete air flow flexibility.

FIELD--INSTALLED ACCESSORIES -- Accessories were
designed for quick and easy installation. The motorized
damper and economizers simply slide in and electrical
connections are made by modular plugs. Electric heaters
mount easily and knockouts are provided in the internal
partitions to connect the elements to the control box single
point kit.

The motorized air damper includes a slid--in/plug--in damper
assembly with a rainhood and filters. The outdoor air dampers
open when the indoor fan motor is energized. The damper is
capable of providing 0% through 100% of outdoor return air
opening.

The manual outdoor damper provides 0% through 35% or 0%
through 100% of return air opening (field adjustable). Designed
for duct mounted side or bottom supply/return applications.
Includes rain hood assembly and filter.

The 14" high roof curb is shipped knocked down. A roof curb
deck is not required because the bottom of the unit is insulated.

WIDE RANGE OF INDOOR AIRFLOWS -- All models operate
over a wide range of design conditions with a 3--speed direct--
drive fan motor. Belt--drive blowers are also available on all
models.

FULL PERIMETER BASE RAILS -- The permanently
attached base rails provide a solid foundation for the entire unit
and protect the unit during shipment. The rails provide fork lift
access from 3 sides and rigging holes are also provided so that
an overhead crane can be used to place the units on a roof.

TECHNICAL GUIDE

036-21564-002-A-0404

® 

SINGLE PACKAGE
AIR-TO-AIR
HEAT PUMPS

B3CH 036, 048 & 060 (208/230, 460V)
B5CH 036 & 060 (575V), B6CH 048
3, 4 AND 5 NOMINAL TONS
(10 SEER)

SUNLINE 2000

Summary of Contents for SUNLINE 2000 48

Page 1: ...DESIGN Both the side and bottom duct openings are covered when they leave the factory If a side supply side return is desired you simply remove the two side duct covers from the outside of the unit an...

Page 2: ...ompressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures AIR FILTERS Units come standard with 1 throwaway filters The unit f...

Page 3: ...eaters available as accessories all with single point power supply SEER Seasonal Energy Efficiency Ratio the total cooling output in BTU s during a normal annual usage period for cooling divided by th...

Page 4: ...l Cap 1 MBH Power Input2 KW Sensible Capacity1 MBH CFM WB F Entering Dry Bulb F Entering Dry Bulb F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 1750 72 44 4 0 31 27 24 20 16 42 4 2 30 26 23 19 15 67 40...

Page 5: ...l Cap 1 MBH Power Input2 KW Sensible Capacity1 MBH CFM WB F Entering Dry Bulb F Entering Dry Bulb F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 2000 72 51 4 9 40 35 29 24 49 5 2 39 34 29 23 67 46 4 7 42...

Page 6: ...l Cap 1 MBH Power Input2 KW Sensible Capacity1 MBH CFM WB F Entering Dry Bulb F Entering Dry Bulb F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 2500 72 64 6 0 51 44 38 31 60 6 9 50 43 37 30 67 59 5 9 51...

Page 7: ...0 4 6 5 2 70 MBH 11 8 16 6 21 6 27 1 34 9 42 8 51 7 59 2 KW 3 5 3 6 3 8 3 8 4 0 4 2 4 8 5 4 80 MBH 10 9 15 3 19 9 24 9 32 1 39 4 47 6 54 5 KW 3 6 3 7 4 0 4 0 4 1 4 4 5 0 5 7 1600 55 MBH 12 1 17 0 22 0...

Page 8: ...NDOOR COIL AND 1 FILTERS REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN HEAT PUMP UNITS WITH SIDE DUCT AIRFLOWS MODEL BCH AIR FLOW CFM Available External Static...

Page 9: ...AND 1 FILTERS REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN HEAT PUMP UNITS WITH SIDE DUCT AIRFLOWS MOTOR AND DRIVE DATA Belt Drive Blower MODEL BLOWER RANGE R...

Page 10: ...PROTECTION REFER TO ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH THE WIRING AND OVERCURRENT PROTECTION 2 3 4 TO REMOTE SENSOR 2TH04702224 IF USED 2 1 24 volt thermostat with subbase 2TH1170022...

Page 11: ...76 6 53 8 63 7 77 7 101 6 125 5 60 70 80 110 150 60 70 80 110 150 230 1 60 2CE04500506 2CE04500706 2CE04501006 2CE04501506 2CE04502006 4 4 5 3 7 5 10 6 15 9 21 2 1 1 1 2 2 22 1 31 2 44 2 66 2 88 3 57...

Page 12: ...2 1 1 2 10 2 15 3 20 4 24 9 30 7 37 1 25 30 40 25 30 40 060 208 1 60 2CE04500506 2CE04500706 2CE04501006 2CE04501506 2CE04502006 2CE04503006 8 6 4 0 5 6 8 0 11 9 15 9 22 2 1 1 1 2 2 2 19 1 27 1 38 3 5...

Page 13: ...6 58 0 67 9 81 9 105 8 129 7 70 80 90 110 150 70 80 90 110 150 230 1 60 2CE04500506 2CE04500706 2CE04501006 2CE04501506 2CE04502006 8 6 5 3 7 5 10 6 15 9 21 2 1 1 1 2 2 22 1 31 2 44 2 66 2 88 3 61 7 7...

Page 14: ...2 1 1 2 10 2 15 3 20 4 24 2 30 5 36 9 25 35 40 25 35 40 060 208 1 60 2CE04500525 2CE04500725 2CE04501025 2CE04501525 2CE04502025 2CE04503025 8 6 4 0 5 6 8 0 11 9 15 9 22 2 1 1 1 2 2 2 19 1 27 1 38 3...

Page 15: ...made from wood or class A B or C roof covering material 2 Units must be installed oudoors Overhanging structures or shrubs should not obstruct outdoor air discharge outlet HOLE KNOCKOUT SIZE DIA USED...

Page 16: ...gain ac cess to the bottom supply air knockout panel 2 Remove and discard the bottom knockout panel 3 Replace the side duct cover 4 With filter section access panel removed from the unit remove and di...

Page 17: ...Y CORNER CORNER CORNER OPTIONS ACCESSORIES Electric Heat Nominal KW 5 7 KW 18 10 15 KW 23 20 30 KW 28 Economizer 50 Motorized Outdoor Air Damper 26 Barometric Relief Fixed Outdoor Air Intake Damper 10...

Page 18: ...ge conditions It contains a 12 5 OHM PTCR temperature resistor with a support clip and hardware for mounting ANTI RECYCLE TIMER A timer to prevent the unit compressor from short cycling It assures 5 m...

Page 19: ...PLICATIONS TYPICAL ROOF TOP INSTALLATION ROOF JACK INSTALLATION ROOF CURB INSTALLATION SLAB ON GROUND INSTALLATION FIELD SUPPLIED DISCONNECT SWITCH TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT...

Page 20: ...all be direct drive multi speed or a factory in stalled belt drive adjustable pitch motor pulley option Job site selected BHP brake horse power shall not ex ceed the motors nameplate horse power ratin...

Page 21: ...utdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the condi tioned space during normal operation During econo mizer operation a mixed a...

Page 22: ...me between compressor cycles 8 ELECTRIC HEAT Slide in design provides single point power and ranges from 5 to 30 KW OTHER FACTORY INSTALLED OPTIONS 1 HIGH PERFORMANCE BELT DRIVE MOTOR 2 TECHNICOAT PHE...

Page 23: ...036 21564 002 A 0404 Unitary Products Group 23...

Page 24: ...Group 5005 York Drive Norman Oklahoma 73069 Subject to change without notice Printed in U S A 035 21564 002 A 0404 Copyright 2004 by York International Corporation All Rights Reserved Supersedes 036...

Reviews: