TECHNICAL GUIDE

STELLAR 2000

SPLIT-SYSTEM AIR CONDITIONERS

10 SEER 50 HZ 

MODELS: H*DA012 THRU H*DA076
(1 & 3 PHASE)

(1 THRU 7.5 NOMINAL TONS)

Due to continuous product improvement, specifica-
tions are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

DESCRIPTION

The HDA Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of UPG's complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required.

FEATURES

QUALITY CONDENSER COILS - 

The coil is constructed

of enhanced copper tube and aluminum fins.

COIL PROTECTION -

 Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

PROTECTED COMPRESSOR -

 The compressor is inter-

nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protect the compressor if undesirable operating conditions
occur. 

DURABLE FINISH -

 Cabinet is made of pre-painted steel.

The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and glossy earth tone finish insure
less fading when exposed to sunlight.

LOWER INSTALLED COST -

 Installation time and costs

are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Both quick connect and sweat connect
models are available. Both service valves are firmly affixed
to the unit. The sweat unit contains enough refrigerant for
matching indoor coils and 15 feet of interconnecting pip-
ing. The small base dimension means less space is
required on the ground or roof.

TOP DISCHARGE -

 The warm air from the top mounted

fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.

LOW OPERATING SOUND LEVEL -

 The upward air flow

carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.

LOW MAINTENANCE -

 Long life permanently lubricated

motor- bearings need no annual servicing.

EASY SERVICE ACCESS -

 Fully exposed refrigerant con-

nections and a single panel covering the electrical controls
make servicing easy.

SECURED SERVICE VALVES -

 Secured re-usable ser-

vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.

FACTORY TESTED -

 to verify system operation and con-

trol functioning before shipment.

Summary of Contents for STELLAR 2000 H*DA012

Page 1: ...lvanized steel provides a better paint to steel bond which resists corrosion and rust creep Special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight LOWER INSTALLED COST Installation time and costs are reduced by easy power and control wiring connec tions Discharge line heat exchanger knockouts are pro vided if required Both quick connect and sweat connect m...

Page 2: ...9 0 9 1 4 0 8 0 8 0 8 1 0 Locked Rotor 1 4 1 4 3 12 1 8 1 8 2 0 1 8 Fan Diameter Inches 18 18 18 18 18 24 24 Fan Motor Rated HP 1 8 1 8 1 4 1 4 1 4 1 4 1 3 Nominal RPM 1075 1075 1100 1075 1075 850 940 Rated Voltage 230 230 230 460 460 460 415 Coil Face Area Sq Ft 9 4 9 4 11 3 11 3 14 1 20 20 0 Rows Deep 1 1 1 1 1 1 2 Fin Inches 16 16 20 20 16 18 13 Liquid Line OD 3 8 3 8 3 8 3 8 3 8 3 8 1 2 Vapor ...

Page 3: ...1 99 12 5 2 09 10 9 2 13 40 68 5 20 8 1 90 17 6 2 07 14 3 2 20 12 6 2 24 45 76 0 22 9 1 97 19 6 2 17 16 2 2 31 14 5 2 37 50 84 0 25 2 2 05 21 8 2 27 18 3 2 43 16 5 2 49 H3DA024 35 61 5 21 9 2 34 18 7 2 54 15 6 2 71 14 0 2 77 40 68 5 24 3 2 41 20 9 2 63 17 6 2 84 15 9 2 91 45 76 0 26 7 2 47 23 2 2 73 19 7 2 97 18 0 3 06 50 84 0 29 3 2 53 25 6 2 82 21 9 3 10 20 0 3 20 H3DA030 35 61 5 27 6 2 64 23 9 ...

Page 4: ...9 00 H3DA0308S78 N1AHB12 5 7 5 10 15 18 17 G2FD030S17 1025 30 0 21 9 3 32 9 70 17 G2FD036S17 1025 30 2 22 0 3 35 9 70 H3DA036S50 N1AHB12 5 7 5 10 15 18 17 G2FD036S17 1200 34 2 24 9 4 05 9 00 21 G2FD046S17 1200 H3DA048S50 N1AHC16 5 7 5 10 15 20 21 G2FD048S21 1550 46 2 34 7 5 06 9 90 N1AHD20 7 5 10 15 20 25 30 24 G2FD048S24 1550 46 2 34 7 5 06 9 90 N1AHD20 7 5 10 15 20 25 30 24 G2FD060S24 1550 47 8 ...

Page 5: ... G W Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA WIRE NEC CLASS 2 FURNACE OR AIR HANDLER TERMINAL BLOCK ROOM THERMOSTAT CONDENSING UNIT TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT POWER WIRING 380 415 3 50 CONTACTOR TERMINALS COIL GND LUG C Y R G W Y R G W POWER WIRING CONTROL WIRING FACTORY WIRING 24 VOLT CONTROL WIRING MINIMUM 18 GA WIRE NEC CLASS...

Page 6: ...l opening s with permagum or equivalent 24 SERVICE ACCESS CLEARANCE 48 OVERHEAD CLEARANCE 12 REAR AND SIDES NOTE All outdoor wiring must be weatherproof AIR HANDLERS FOR NON FURNACE APPLICATIONS N1AH MODULAR BLOWER UPFLOW HORIZONTAL AND DOWNFLOW F2RP FAN COIL UNITS UPFLOW HORIZONTAL G2FD COIL K EU060 090 LIGHT COMMERCIAL APPLICATIONS G2FD MULTI POSITION UPFLOW HORIZONTAL AND DOWNFLOW ADD ON COILS ...

Page 7: ...036 21105 004 Rev A 0902 Unitary Products Group 7 NOTES ...

Page 8: ...hange without notice Printed in U S A 036 21105 004 Rev A 0902 Copyright by York International Corp 2002 All rights reserved Supersedes 036 21105 003 Rev C 0901 Unitary 5005 Norman Product York OK Group Drive 73069 ...

Reviews: