036-21105-004 Rev. A (0902)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
®
TECHNICAL GUIDE
STELLAR 2000
SPLIT-SYSTEM AIR CONDITIONERS
10 SEER 50 HZ
MODELS: H*DA012 THRU H*DA076
(1 & 3 PHASE)
(1 THRU 7.5 NOMINAL TONS)
Due to continuous product improvement, specifica-
tions are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
DESCRIPTION
The HDA Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom-
matched with one of UPG's complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
application to provide a complete system. Electric heaters are
available if required.
FEATURES
•
QUALITY CONDENSER COILS -
The coil is constructed
of enhanced copper tube and aluminum fins.
•
COIL PROTECTION -
Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
•
PROTECTED COMPRESSOR -
The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protect the compressor if undesirable operating conditions
occur.
•
DURABLE FINISH -
Cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and glossy earth tone finish insure
less fading when exposed to sunlight.
•
LOWER INSTALLED COST -
Installation time and costs
are reduced by easy power and control wiring connec-
tions. Discharge line heat exchanger knockouts are pro-
vided, if required. Both quick connect and sweat connect
models are available. Both service valves are firmly affixed
to the unit. The sweat unit contains enough refrigerant for
matching indoor coils and 15 feet of interconnecting pip-
ing. The small base dimension means less space is
required on the ground or roof.
•
TOP DISCHARGE -
The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
•
LOW OPERATING SOUND LEVEL -
The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
•
LOW MAINTENANCE -
Long life permanently lubricated
motor- bearings need no annual servicing.
•
EASY SERVICE ACCESS -
Fully exposed refrigerant con-
nections and a single panel covering the electrical controls
make servicing easy.
•
SECURED SERVICE VALVES -
Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
•
FACTORY TESTED -
to verify system operation and con-
trol functioning before shipment.