background image

291891-YUM-A-0207

4

Unitary Products Group

Immediately call your gas sup-
plier from a neighbor's phone. 
Follow the gas supplier's 
instructions.

If you cannot reach your gas 
supplier, call the fire department.

A.

Use only your hand to push in or 
turn the gas control knob. Never 
use tools. If the knob will not push 
in or turn by hand, don't try to repair 
it, call a qualified service techni-
cian. Force or attempted repair may 
result in a fire or explosion.

B. Do not use this appliance if any 

part has been under water. 
Immediately call a qualified 
service technician to inspect 
the appliance and to replace 
any part of the control system 
and any gas control which has 
been under water.

START-UP INSTRUCTIONS 
- HEATING SYSTEM

NOTE:  

See General instructions for

Start-up and Shutdown of
your gas heating system.

1. STOP! Read the safety informa-

tion.

2. Set the thermostat to the lowest 

setting.

3. Make sure all electrical power to 

the furnace is “OFF”.

4. This appliance has a device 

which automatically lights the 
pilot and inturn, lights the burn-
ers.

5. Remove burner access panel 

by removing screws and lifting 
panel out.

6. Push the manual gas switch to 

the “OFF” position.

7. Wait five (5) minutes to clear out 

any gas. If you then smell gas, 
STOP! Follow step A in the 
safety information. If you don't 
smell gas, go to next step.

8. Push the manual gas switch to 

the ON position.

9. Replace the control access 

panel.

10.Turn on all electrical power to 

the appliance.

11. Set the thermostat to the 

desired setting.

12.If the appliance will not operate, 

follow the instruction “To Turn 
OFF Gas To Application” and 
call your service technician or 
gas supplier.

SHUTDOWN INSTRUCTION 
- TO TURN OFF GAS TO 
APPLIANCE

1. Set the thermostat to the lowest 

setting.

2. Turn off all electrical power to the 

appliance if service is to be per-
formed.

3. Remove burner access panel by 

removing screws and lifting 
panel out.

4. Turn the manual gas switch to 

the “OFF” position.

5. Replace the control access 

panel.

SECURE OWNER’S APPROVAL

When the system is functioning
properly, secure the owner’s
approval. Show the owner the loca-
tion of all disconnect switches and
the thermostat. Teach owner how
to start and stop the unit and how
to adjust temperature settings
within the limitations of the system.
Advise owner that the flue exhaust
hood surface and the immediate

Should overheating occur,
or the gas supply fail to
shut off, shut off the man-
ual gas valve to the fur-
nace before shutting off
the electrical supply.

Manual

Gas Switch

ELECTRICAL SHOCK,
FIRE OR EXPLOSION
HAZARD

Failure to follow safety
warnings exactly could
result in dangerous opera-
tion, serious injury, death
or property damage.

Improper servicing could
result in dangerous opera-
tion, serious injury, death
or property damage.

• Before servicing, discon-

nect all electrical power to 
furnace.

• When servicing controls, 

label all wires prior to dis-
connecting. Reconnect 
wires correctly.

• Verify proper operation 

after servicing.

Manual

Gas

Switch

WARNING

Summary of Contents for SINGLE PACKAGE AIR CONDITIONER GAS

Page 1: ... BEFORE CALLING A SERVICE PERSON 6 REPLACEMENT PARTS 6 SOME EFFICIENCY DO S AND DONT S 6 The manufacturer recommends that the User read all sections of this manual and keep the manual for future reference FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or prop erty damage Do not store or use gasoline or other flam mable vapors and liquids in ...

Page 2: ...l to the roof Elec tric air conditioning in the summer and gas heating in the winter all from a single unit SYSTEM OPERATION THERMOSTATS Set your thermostat for either heat ing or cooling then set it for the desired temperature DO NOT MOVE THE THERMOSTAT RAP IDLY ON AND OFF OR BACK AND FORTH FROM HEAT TO COOL THIS COULD DAMAGE YOUR EQUIPMENT Always allow at least 5 minutes between changes Find the...

Page 3: ...a cool fan off delay timing of 30 seconds the circulating fan is de energized CIRCULATING FAN When the thermostat calls for FAN the thermostat terminal sig nals the circulating fan to run at the cool speed If a call for COOL occurs the cir culating fan continues to run at the cool speed If a call for HEAT occurs the cir culating fan switches to heat speed after a 30 second delay When the thermosta...

Page 4: ...access panel 10 Turn on all electrical power to the appliance 11 Set the thermostat to the desired setting 12 If the appliance will not operate follow the instruction To Turn OFF Gas To Application and call your service technician or gas supplier SHUTDOWNINSTRUCTION TO TURN OFF GAS TO APPLIANCE 1 Set the thermostat to the lowest setting 2 Turn off all electrical power to the appliance if service i...

Page 5: ...l clean Use a brush vacuum cleaner attachment or other suitable means If water is used to clean the coil be sure that the power to the unit is shut off prior to cleaning BURNER At the beginning of each heating season make a visual check of the main burner flame If it is not possi ble to adjust for the proper flame the burner may need cleaning TO CLEAN BURNERS Remove them from the furnace as explai...

Page 6: ... room DO select a comfortable thermostat setting but keep in mind that mod eration in temperature selection will save energy DO turn on your kitchen exhaust fan when cooking and your bath room exhaust fan when showering Also make sure your clothes dryer is properly vented If these items are neglected an excess heat and humidity condition may be created causing your air conditioning sys tem to run ...

Page 7: ...291891 YUM A 0207 Unitary Products Group 7 ...

Page 8: ...ut notice Printed in U S A 291891 YUM A 0207 Copyright by Unitary Products Group 2007 All rights reserved Supersedes Nothing Unitary 5005 Norman Products York OK Group Drive 73069 ISO 9001 Certified Quality Management System ...

Reviews: