![background image](http://html1.mh-extra.com/html/york/r-410a/r-410a_technical-manual_3500847009.webp)
333495-YTG-C-0908
Johnson Controls Unitary Products
9
BHZ and BHX Unit Limitations
Size
(Tons)
Model
Unit Voltage
Unit Limitations
Applied Voltage
Outdoor DB Temp
Min
Max
Max (°F)
024
(2.0)
BHZ
208/230-1-60
187
252
125
BHX
208/230-1-60
187
252
115
030
(2.5)
BHZ
208/230-1-60
187
252
125
208/230-3-60
187
252
125
460-3-60
432
504
125
036
(3.0)
BHZ
208/230-1-60
187
252
125
208/230-3-60
187
252
125
460-3-60
432
504
125
BHX
208/230-1-60
187
252
115
208/230-3-60
187
252
115
460-3-60
432
504
115
042
(3.5)
BHZ
208/230-1-60
187
252
125
208/230-3-60
187
252
125
460-3-60
432
504
125
048
(4.0)
BHZ
208/230-1-60
187
252
125
208/230-3-60
187
252
125
460-3-60
432
504
125
BHX
208/230-1-60
187
252
115
208/230-3-60
187
252
115
460-3-60
432
504
115
060
(5.0)
BHZ
208/230-1-60
187
252
125
208/230-3-60
187
252
125
460-3-60
432
504
125
BHX
208/230-1-60
187
252
115
208/230-3-60
187
252
115
460-3-60
432
504
115