ACCESSORIES

PROPANE (LP) CONVERSION KIT - 

1NP0580 - All units

This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation. Conversions must
be made by qualified distributor or dealer personnel.

CONCENTRIC VENT TERMINATION - 

1CT0302 (2")

1CT0303 (3")

For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole.

CONDENSATE NEUTRALIZER KIT - 1NK0301
Neutralizer cartidge has a 1/2" plastic tube fittings for installa-
tion in the drain line. Calcium carbonate refill media is also
avaiable from the Source 1 Parts (p/n 026-30228-000).

SIDEWALL VENT TERMINATION - 1HT0901
For use on sidewall, two-pipe installations only. Provides a
more attractive termination for locations where the terminal is
visible on the side of the home.

EXTERNAL SIDE RETURN FILTER RACK -

1SF0101 - Fits all cabinet sizes
Attaches to side of furnace cabinet in side return applications.
Holds any 16x25x1 permanent or disposable filter.

SIDE RETURN FILTER - 

1SR0302 - All Models

1SR0200 - All Models

BOTTOM RETURN FILTER - 

1BR0114 or 1BR0214 - For 14-1/2” cabinets

1BR0117 or 1BR0217 - For 17-1/2” cabinets

1BR0121 or 1BR0221 - For 21” cabinets

1BR0124 or 1BR0224 - For 24-1/2” cabinets

INTERNAL FILTER WITH FIBER FILTER - 

1HF0801 - All Models

HIGH ALTITUDE PRESSURE SWITCHES - 

For installation where the altitude is less than 8,000 feet it is
not required that the pressure switch be changed. For alti-
tudes above 8,000 feet see kits below. Conversion must be
made by qualified distributor or dealer personnel.

1PS0501 - 060 MBH
1PS0502 - 080/1200 MBH
1PS0503 - 080/1600, 120 MBH
1PS0505 - 100 MBH
1PS0506 - 040 MBH

ROOM THERMOSTATS - A wide selection of compatible
thermosets are available to provide optimum performance
and features for any installation.

1H/1C, manual change-over electronic non-programmable 
thermostat.

1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.

1H/1C, auto/manual changeover, electronic programmable.

* For the most current accessory information, refer to the
price book or consult factory.

Summary of Contents for PV9A12N040UP11

Page 1: ...gas valve Two stage inducer operation Variable speed ECM blower operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code dis...

Page 2: ...TTOM IMAGE RETURN END TOP IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O CABINET AND DUCT DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A in B in C in D in PV9A12N040UP11 1200 A 14 1 2 13 1 2 12 1 8 6 1 4 PV9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9C16N080UP11 1600 C ...

Page 3: ...om two sides or one side plus bottom ELECTRICAL AND PERFORMANCE DATA Models Input High Low Output High Low Nominal Airflow Cabinet Width Total Unit AFUE Air Temp Rise MBH MBH CFM In Amps F PV9A12N040UP11 40 26 38 24 1200 14 1 2 9 94 0 35 65 PV9B12N060UP11 60 39 56 36 1200 17 1 2 9 93 2 40 70 PV9B12N080UP11 80 52 75 49 1200 17 1 2 9 92 5 45 75 PV9C16N080UP11 80 52 75 49 1600 21 12 92 8 45 75 PV9C20...

Page 4: ... 1490 920 C A 1250 790 1290 790 D A 1310 810 1360 840 C C 1090 690 1140 690 D C HIGH LOW HEAT CFM 40 000 INPUT 3 Ton 60 000 INPUT 3 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1045 740 1110 710 A Any 905 645 960 640 B Any 825 595 870 600 C Any 765 590 830 570 D Any 80 000 INPUT 3 Ton 80 000 INPUT 4 Ton JUMPER SETTINGS CFM CFM High Low High Low HEAT Tap ADJ Tap 1330 880 1490 990 ...

Page 5: ...d upon the number of return air openings or return air opening size and add to the ESP from Step 3 to determine the total system static 5 If total system static matches a ESP value in the airflow table i e 0 20 0 60 etc the system airflow corre sponds to the intersection of the ESP column and Model Blower Speed row FILTER SIZES Input Output BTU H CFM Cabinet Size Side Return Filter in Bottom Retur...

Page 6: ...ight O Reversing Valve Energized in Cool TWO STAGE AIR CONDITIONING Comfort Alert Interface HUM Dehumidification Open on Humidity Rise C 24 Volt Common C 24 Volt Common R 24 Volt Hot W2 Second Stage Heat G Fan Y2 Second Stage Cool E W1 First Stage Heat RC 24 Volt Hot Cool XFMR Y1 First Stage Cool R 24 Volt Hot Y Y2 Single Second Stage Cool Y2 Second Stage Cool Y First Stage Cool Y2 Second Stage Co...

Page 7: ...2 Delay on furnace to OFF HM Humidistat BSG Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Heat W Auxiliary Heat Y2 Second Stage Heat Cool DHM Dehumidistat HUM Dehumidification Open on Humidity Rise Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y 2 O Reversing Valve Energized in Coo...

Page 8: ...SIDE RETURN FILTER RACK 1SF0101 Fits all cabinet sizes Attaches to side of furnace cabinet in side return applications Holds any 16x25x1 permanent or disposable filter SIDE RETURN FILTER 1SR0302 All Models 1SR0200 All Models BOTTOM RETURN FILTER 1BR0114 or 1BR0214 For 14 1 2 cabinets 1BR0117 or 1BR0217 For 17 1 2 cabinets 1BR0121 or 1BR0221 For 21 cabinets 1BR0124 or 1BR0224 For 24 1 2 cabinets IN...

Reviews: