ACCESSORIES

PROPANE (LP) CONVERSION KIT - 

1NP0580 - All units

This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation. Conversions must
be made by qualified distributor or dealer personnel.

CONCENTRIC VENT TERMINATION -

 

1CT0302 (2")

1CT0303 (3")

For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole.

CONDENSATE NEUTRALIZER KIT - 1NK0301

Neutralizer cartidge has a 1/2" plastic tube fittings for installa-
tion in the drain line. Calcium carbonate refill media is also
avaiable from the Source 1 Parts (p/n 026-30228-000).

Sidewall Vent Termination - 1HT0901 

For use on sidewall, two-pipe installations only. Provides a
more attractive termination for locations where the terminal is
visible on the side of the home.

EXTERNAL BOTTOM RETURN FILTER RACK W/FILTER -

 

Provides a cleanable, high velocity type filter and filter rack.
Attaches to the bottom of the furnace.

1BR0314 - For 14-1/2” cabinets

1BR0317 - For 17-1/2" cabinets

1BR0321 - For 21" cabinets

1BR0324 - For 24-1/2" cabinets

HIGH ALTITUDE PRESSURE SWITCHES - 

These accessory kits may be used to convert units for high
altitude operation. Conversion must be made by qualified dis-
tributor or dealer personnel.

1PS0501

HIGH ALTITUDE PRESSURE 

SWITCH KIT 

(Does Not Include Orifices)

FOR APPLICATION

INFORMATION 

SEE FORM 

035-20506-001

1PS0502
1PS0503
1PS0504
1PS0505
1PS0506

FIELD INSTALLED ACCESSORIES - ELECTRICAL 

MODEL NO.

DESCRIPTION

USED WITH

2TH07700124

THERMOSTAT- One-stage heat/cool. Manual changeover, integral subbase. 

System Switch: Cool-Off-Heat.  Fan Switch: Auto-On.

ALL MODELS

2TH13700424

THERMOSTAT- One-stage heat. Deluxe 24V with heat only subbase, does not 
include fan switch.  NOTE: For one-stage cool or one-stage heat/cool, must be 

used with subbase 2TB17700424.

ALL MODELS

2TB17700424

SUBBASE (24V) - One-stage heat/cool. Manual changeover, integral subbase. 

System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2ET07700224

THERMOSTAT- One-stage heat/cool. Programmable changeover, with sub-

base. System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

Summary of Contents for PV9

Page 1: ...age inducer operation Variable speed ECM blower operation Provides increased comfort level very quiet unit oper ation Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SEER improvement Easy to connect power control wiring Built in high level self diagnostics with fault code display Low unit am...

Page 2: ...nsion Air Intake A in B in C in D in PV9A12N040UP11 1200 A 14 1 2 13 1 2 12 1 8 6 1 4 PV9B12N060UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9B12N080UP11 1200 B 17 1 2 16 1 4 15 1 8 8 1 2 PV9C16N080UP11 1600 C 21 19 3 4 18 1 2 8 7 8 PV9C20N100UP11 2000 C 21 19 3 4 18 1 2 8 7 8 PV9D20N120UP11 2000 D 24 1 2 23 1 4 21 7 8 10 5 8 COMBUSTION AIR SUPPLY AND VENT PIPING MAXIMUM ELBOWS AND VENT LENGTHS Models...

Page 3: ...V9B12N080UP11 1PS0502 PV9C16N080UP11 1PS0503 PV9C20N100UP11 1PS0505 PV9D20N120UP11 1PS0503 ELECTRICAL AND PERFORMANCE DATA Models Input High Low Output High Low Nominal Airflow AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Total Unit Max Over current Protect Min Wire Size awg 75 ft One Way MBH MBH CFM F F HP Amps In Amps PV9A12N040UP11 40 26 38 24 1200 94 0 35 65 165 1 2 7 7 11x8 9 20 ...

Page 4: ...1880 1250 53 2 35 4 A C 1560 1010 44 2 28 6 1620 1030 45 9 29 2 C B 1470 940 41 6 26 6 1500 960 42 5 27 2 B C 1370 890 38 8 25 2 1410 880 39 9 24 9 D B 1460 930 41 3 26 3 1490 920 42 2 26 1 C A 1250 790 35 4 22 4 1290 790 36 5 22 4 D A 1310 810 37 1 22 9 1360 840 38 5 23 8 C C 1090 690 30 9 19 5 1140 690 32 3 19 5 D C HIGH LOW HEAT CFM 40 000 INPUT 3 Ton 60 000 INPUT 3 Ton JUMPER SETTINGS CFM m mi...

Page 5: ...em static 5 If total system static matches a ESP value in the airflow table i e 0 20 0 60 etc the system airflow corre sponds to the intersection of the ESP column and Model Blower Speed row BLK WHT GRN BLK HOT WHT NEUTRAL GRN NOMINAL 120 VOLT LINE WIRING CONNECTIONS SINGLE STAGE HEATING THERMOSTAT CONNECTIONS SINGLE STAGE HEATING AND TWO STAGE COOLING THERMOSTAT CONNECTIONS ROOM THERMOSTAT FURNAC...

Page 6: ...to the bottom of the furnace 1BR0314 For 14 1 2 cabinets 1BR0317 For 17 1 2 cabinets 1BR0321 For 21 cabinets 1BR0324 For 24 1 2 cabinets HIGH ALTITUDE PRESSURE SWITCHES These accessory kits may be used to convert units for high altitude operation Conversion must be made by qualified dis tributor or dealer personnel 1PS0501 HIGH ALTITUDE PRESSURE SWITCH KIT Does Not Include Orifices FOR APPLICATION...

Page 7: ...036 21584 001 Rev B 1004 Unitary Products Group 7 NOTES ...

Page 8: ...e without notice Printed in U S A 036 21584 001 Rev B 1004 Copyright by York International Corp 2004 All rights reserved Supersedes 036 21584 001 Rev a 0904 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...

Reviews: