TABLE 15: ELECTRICAL DATA DF120 (10 TON) MID EFFICIENCY W/O PWRD CONVENIENCE OUTLET
TABLE 16: ELECTRICAL DATA DF120 (10 TON) MID EFFICIENCY WITH PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
2
3
2
3
2
3
2
3
2
3
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
51.2
53.9
56.7
59.4
60
60
70
70
2TP04521825
13.5
37.5
57.1
60.5
64.0
67.3
60
70
70
70
2TP04522425
18.0
50.0
72.7
76.1
79.6
83.0
80
80
80
90
2TP04523625
25.5
70.8
98.7
102.1 105.6 109.0 100 110
110
110
2TP04525425 40.6
112.7 151.1 154.5 158.0 161.4 175 175
175
175
None
--
--
51.2
53.9
56.7
59.4
60
60
70
70
2TP04521825
18.0
43.3
64.4
67.8
71.3
74.6
70
70
80
80
2TP04522425
24.0
57.7
82.4
85.8
89.3
92.7
90
90
90
100
2TP04523625
34.0
81.8
112.5 115.9 119.4 122.7 125 125
125
125
2TP04525425 54.0
129.9 140.2 143.5 147.0 150.4 150 175
175
175
None
--
--
26
27.2 28.2 29.4 30 35
35
35
2TP04521846
18
22.6
32.2 33.7 34.9 36.4 35 35
35
40
2TP04522446
24
30.1
41.2 42.7
44 45.5 45 45
45
50
2TP04523646
34
42.7
56.2 57.7
59 60.5 60 60
60
70
2TP04525446
54
67.8
70.1 71.6 72.8 74.3 80 80
80
80
None
--
--
20.6 21.1 22.4 22.9 25 25
25
25
2TP04521858
18
18.1
26.2 26.8 28.4 29 30 30
30
30
2TP04522458
24
24.1
33.4
34
35.6 36.2 35 35
40
40
2TP04523658
34
34.1
45.4
46
47.6 48.3 50 50
50
50
2TP04525458
54
54.2
56.5
57.1 58.7 59.3 70 70
70
70
*
5.5
0.0
Pwr
Conv
Outlet
6.4
58.0
1.3
3.6
4.1
1.8
0.0
0.0
0.0
5.5
2.2
3.5
8.2
Maximum HACR breaker of the same AMP size is applicable.
8.3
69.0
1.6
4.1
5.3
230
460
575
10.9
16.0
137.0
3.5
8.2
MCA
w/Power
Exhaust
(Amps)
Max
Fuse
*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Electric Heater
Model No.
Actual
KW
Min. Circuit
Ampacity
(Amps)
Heater
Amps
FLA
Voltage
208
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
10.9
16.0
137.0
RLA
LRA
FLA
2
3
2
3
2
3
2
3
2
3
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
61.2
63.9
66.7
69.4
70
70
80
80
2TP04521825
13.5
37.5
69.6
73.0
76.5
79.8
70
80
80
80
2TP04522425
18.0
50.0
85.2
88.6
92.1
95.5
90
90
100
100
2TP04523625
25.5
70.8
111.2 114.6 118.1 121.5 125 125
125
125
2TP04525425 40.6
112.7 163.6 167.0 170.5 173.9 175 175
175
175
None
--
--
61.2
63.9
66.7
69.4
70
70
80
80
2TP04521825
18.0
43.3
76.9
80.3
83.8
87.1
80
90
90
90
2TP04522425
24.0
57.7
94.9
98.3 101.8 105.2 100 100
110
110
2TP04523625
34.0
81.8
125.0 128.4 131.9 135.2 125 150
150
150
2TP04525425 54.0
129.9 152.7 156.0 159.5 162.9 175 175
175
175
None
--
--
31
32.2 33.2 34.4 35 40
40
40
2TP04521846
18
22.6
38.4 39.9 41.2 42.7 40 40
45
45
2TP04522446
24
30.1
47.5
49
50.2 51.7 50 50
60
60
2TP04523646
34
42.7
62.5
64
65.2 66.7 70 70
70
70
2TP04525446
54
67.8
76.3 77.8 79.1 80.6 90 90
90
90
None
--
--
24.6 25.1 26.4 26.9 30 30
30
30
2TP04521858
18
18.1
31.2 31.8 33.4 34 35 35
35
35
2TP04522458
24
24.1
38.4
39
40.6 41.2 40 40
45
45
2TP04523658
34
34.1
50.4
51
52.6 53.3 60 60
60
60
2TP04525458
54
54.2
61.5
62.1 63.7 64.3 70 70
70
70
*
4.1
1.8
4.0
6.4
58.0
1.3
3.6
8.2
10.9
5.5
10.0
10.0
FLA
5.5
16.0
137.0
3.5
230
460
575
Maximum HACR breaker of the same AMP size is applicable.
8.3
69.0
1.6
4.1
5.3
2.2
5.0
Max
Fuse
*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
208
16.0
137.0
3.5
10.9
8.2
Compressors
OD Fan
Motors
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Voltage
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
FLA