background image

5219967-UTG-A-0716

Johnson Controls Unitary Products

19

1. Airflow tested with dry coil conditions, without air filters, at 230 volts
2. Applications above 0.8" w.c. external static pressure are not recommended.
3. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies.
4. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases.
5. Minimal variations in airflow performance data results from using downflow duct applications. Data above may be used in those cases.

60100

Continuous 

Fan

A 2077

2043

2006

1961

1922

1880

1836

1789

1744

1696

B 1879

1843

1807

1763

1723

1679

1635

1590

1536

1493

C 1683

1648

1604

1560

1515

1468

1424

1377

1330

1284

D 1497

1451

1402

1354

1305

1258

1206

1156

1103

1055

High Cool

A 2149

2114

2077

2030

1989

1948

1905

1859

1816

1768

B 2013

1977

1941

1898

1860

1816

1772

1726

1677

1630

C 1936

1900

1864

1822

1783

1739

1695

1649

1597

1551

D 1719

1685

1642

1600

1555

1508

1465

1418

1372

1327

Low Cool

A 1629

1591

1546

1502

1455

1409

1362

1315

1266

1220

B 1558

1516

1469

1423

1375

1329

1280

1232

1181

1135

C 1453

1406

1355

1305

1255

1207

1153

1100

1047

997

D 1410

1361

1307

1255

1204

1155

1100

1044

992

938

High Heat

A 1739

1705

1664

1620

1577

1530

1487

1441

1393

1348

B 1558

1516

1469

1423

1375

1329

1280

1232

1181

1135

C 1410

1361

1307

1255

1204

1155

1100

1044

992

938

D 1323

1270

1213

1156

1104

1052

993

933

880

821

Low Heat

A 1594

1553

1507

1462

1415

1369

1321

1274

1223

1178

B 1323

1270

1213

1156

1104

1052

993

933

880

821

C 1181

1118

1049

980

913

857

795

743

696

640

D 1025

950

868

788

713

654

591

505

458

415

60125

Continuous 

Fan

A 2077

2043

2006

1961

1922

1880

1836

1789

1744

1696

B 1879

1843

1807

1763

1723

1679

1635

1590

1536

1493

C 1683

1648

1604

1560

1515

1468

1424

1377

1330

1284

D 1497

1451

1402

1354

1305

1258

1206

1156

1103

1055

High Cool

A 2149

2114

2077

2030

1989

1948

1905

1859

1816

1768

B 2013

1977

1941

1898

1860

1816

1772

1726

1677

1630

C 1936

1900

1864

1822

1783

1739

1695

1649

1597

1551

D 1719

1685

1642

1600

1555

1508

1465

1418

1372

1327

Low Cool

A 1629

1591

1546

1502

1455

1409

1362

1315

1266

1220

B 1558

1516

1469

1423

1375

1329

1280

1232

1181

1135

C 1453

1406

1355

1305

1255

1207

1153

1100

1047

997

D 1410

1361

1307

1255

1204

1155

1100

1044

992

938

High Heat

A 2259

2221

2183

2142

2099

2060

2015

1975

1931

1882

B 2093

2059

2023

1977

1938

1896

1852

1805

1760

1712

C 1908

1872

1835

1792

1753

1709

1665

1619

1566

1522

D 1760

1726

1685

1641

1598

1552

1510

1463

1413

1370

Low Heat

A 2259

2221

2183

2142

2099

2060

2015

1975

1931

1882

B 1965

1929

1893

1851

1813

1769

1724

1678

1628

1580

C 1701

1666

1623

1580

1535

1488

1445

1397

1351

1305

D 1683

1648

1604

1560

1515

1468

1424

1377

1330

1284

AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued)

Model

Jumper Position

External Static Pressure (Inches WC)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

SCFM

Summary of Contents for PCG6 24 Series

Page 1: ...t Test stations using a state of the art computerized process system are used to ensure product quality Refrigerant charge and component part numbers are verified via computers during assembly Vital run test statistics such as system pressure motor cur rents air velocity and temperature unit vibration and gas system safeties are monitored and recorded by the system to ensure unit performance Equal...

Page 2: ...re mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures All wiring internal to the unit is color number coded Protected Compressor The compressor is internally pro tected against high pressure and temperature This is accomplished by the simultaneous operation of high pres sure relief valve and a temper...

Page 3: ...000 BTU etc 9 Revision Level A original release B second release Examples PCG4B421002X1A is a packaged A C with gas heat 14 SEER 3 1 2 ton large cabinet single stage heat 100 000 BTU gas heat 230 volt single phase low NOx model first generation first release COMPONENT LOCATION FAN MOTOR OUTDOOR FAN COIL GUARD PANEL OUTDOOR COIL Behind Panel CONTROL BOARD TRANSFORMER HIGH VOLTAGE CONTACTOR PRESSURE...

Page 4: ...pable of providing 0 through 50 of outdoor air field supplied Closes on power loss includes hood and screen assembly Rectangle to Round Horizontal Adapter S1 1AK0110 S1 1AK0111 Kit includes one supply and one return air rectangle to round duct adapter Adapters are preformed and designed to fit over current horizontal duct openings on the base unit Transition is from rectangle to 12 round for the 1...

Page 5: ...gn Fan wheel shall be double inlet type with forward curved blades dynamically balanced to operate smoothly throughout the entire range of operation Airflow design shall be constant air volume Bearings shall be sealed and permanently lubricated for longer life and no maintenance Fan assembly shall be a slide out design for easy removal and cleaning Indoor blower motors shall be equipped with a sta...

Page 6: ... inches Length 51 1 4 51 1 4 51 1 4 51 1 4 51 1 4 51 1 4 Width 35 3 4 35 3 4 45 3 4 45 3 4 45 3 4 45 3 4 Height 47 47 49 49 53 55 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Condenser Coil Data Face area Sq Ft 15 1 15 1 19 5 19 5 23 8 25 9 Rows 1 2 2 2 2 2 Fins per inch 22 22 22 22 22 22 Tube diameter 3 8 3 8 3 8 3 8 3 8 3 8 Circuitry Type Interlaced Interlaced Interlaced Interlaced ...

Page 7: ...4 9 4 10 2 6 9 12 1 11 3 10 7 12 1 8 1 K W 1 59 1 58 1 58 1 55 1 56 1 54 1 53 1 54 1 52 1 53 1 49 1 48 1 50 1 48 1 50 COOLING PERFORMANCE DATA 2 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6A24 CONDENSER ENTERING AIR TEMPERATURE ID CFM 600 800 1000 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 26 0 28 6 28 4 30 0 31 7 28 0 29 9 29 7 31 2...

Page 8: ... 4 11 2 10 9 11 5 8 7 10 5 11 5 11 7 12 9 9 9 K W 2 71 2 71 2 70 2 69 2 71 2 69 2 69 2 69 2 67 2 70 2 66 2 66 2 67 2 66 2 70 COOLING PERFORMANCE DATA 2 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6A30 CONDENSER ENTERING AIR TEMPERATURE ID CFM 750 950 1150 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 31 5 35 1 34 4 39 1 42 4 34 1 37 4 ...

Page 9: ... 2 22 8 19 4 21 0 13 9 23 6 24 5 22 4 23 4 14 7 K W 5 60 5 58 5 55 5 54 5 46 5 52 5 53 5 53 5 49 5 42 5 44 5 48 5 51 5 44 5 38 COOLING PERFORMANCE DATA 3 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B36 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1000 1200 1400 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 45 0 53 3 52 6 55 8 57 3 47 0 52 ...

Page 10: ...7 14 6 17 3 18 5 11 7 15 6 15 6 19 3 20 8 13 1 K W 2 45 2 45 2 42 2 44 2 42 2 46 2 46 2 44 2 45 2 43 2 47 2 47 2 46 2 45 2 44 COOLING PERFORMANCE DATA HIGH 3 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B42 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1120 1320 1520 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 43 6 47 7 30 8 50 0 55 0 45...

Page 11: ...4 17 5 12 5 20 4 11 4 17 9 17 6 11 8 22 3 12 1 K W 3 98 4 10 3 98 3 91 3 89 3 99 4 05 4 00 3 92 3 93 4 00 4 01 4 02 3 93 3 97 COOLING PERFORMANCE DATA HIGH 4 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B48 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1400 1600 1800 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 46 5 54 3 55 5 56 6 59 6 47 9...

Page 12: ... 24 3 27 5 24 6 25 9 18 4 25 1 26 7 25 2 27 5 19 6 K W 4 57 4 38 4 39 4 35 4 32 4 58 4 47 4 49 4 46 4 43 4 58 4 57 4 59 4 56 4 54 COOLING PERFORMANCE DATA 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCG6B60 CONDENSER ENTERING AIR TEMPERATURE ID CFM 1600 1800 2000 IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 55 45 T C 59 2 68 9 66 5 71 8 77 1 61 3 ...

Page 13: ...f covering materials only if factory base rails are left in place as shipped 1 INDOOR BLOWER SPECIFICATIONS Model Motor HP RPM EFF SF Frame 24050 30050 1 3 Variable 0 8 1 0 48 24075 30075 36065 1 2 Variable 0 8 1 0 48 36100 42065 42100 48065 48100 48125 3 4 Variable 0 8 1 0 48 60065 60100 60125 1 Variable 0 8 1 0 48 SOUND PERFORMANCE Model Tons Sound Rating1 dB A 1 Rated in accordance with AHRI St...

Page 14: ...152 9 42 0 1 7 7 0 42 3 60 1 Minimum Circuit Ampacity 2 Maximum Over Current Protection per standard UL 1995 3 Fuse or HACR circuit breaker size installed at factory or field installed WEIGHTS DIMENSIONS Model Weight lbs Center of Gravity 4 Point Load Location lbs Shipping Operating X Y A B C D 24050 372 367 28 15 120 95 81 71 24075 382 377 28 15 124 96 81 76 30050 417 412 28 15 139 99 90 84 30075...

Page 15: ...1 B 927 867 813 761 717 667 612 561 524 487 C 870 761 699 649 605 539 484 449 422 370 D 799 623 552 475 436 387 338 294 237 192 Low Cool A 902 822 764 713 669 612 557 513 480 437 B 855 734 669 615 572 509 454 418 385 334 C 827 678 611 545 504 448 396 356 311 263 D 675 546 466 404 347 277 205 160 126 80 High Heat A 1184 1161 1124 1084 1041 994 954 913 872 822 B 1076 1047 1011 967 912 875 833 790 73...

Page 16: ...02 709 646 582 528 467 402 C 882 805 741 625 556 501 415 359 297 228 D 805 718 642 523 436 376 294 247 193 118 High Heat A 1126 1067 1006 945 860 777 718 664 608 551 B 1015 952 884 802 709 646 582 528 467 402 C 955 886 821 721 642 584 508 453 391 324 D 910 836 774 661 592 537 453 396 333 265 Low Heat A 970 902 837 742 659 599 527 472 410 343 B 818 732 659 540 456 397 314 265 211 136 C 766 674 593 ...

Page 17: ...8 907 839 785 733 663 598 C 1025 966 892 823 756 684 625 575 494 427 D 964 900 816 742 672 596 534 485 398 329 High Heat A 1704 1667 1645 1612 1572 1520 1477 1419 1384 1327 B 1506 1468 1441 1404 1358 1302 1259 1203 1159 1101 C 1322 1278 1238 1191 1138 1077 1030 975 920 859 D 1251 1205 1157 1107 1051 987 938 884 824 761 Low Heat A 1392 1352 1318 1276 1226 1168 1123 1067 1017 957 B 1251 1205 1157 11...

Page 18: ...374 1333 1298 1255 1204 1145 1100 1044 993 933 C 1322 1278 1238 1191 1138 1077 1030 975 920 859 D 1286 1241 1197 1149 1095 1032 984 930 872 810 High Heat A 2114 2046 1974 1914 1874 1815 1745 1696 1645 1582 B 1982 1930 1887 1844 1806 1752 1697 1643 1604 1545 C 1785 1746 1720 1687 1647 1596 1551 1494 1459 1402 D 1614 1578 1554 1520 1477 1424 1382 1324 1286 1228 Low Heat A 2114 2046 1974 1914 1874 18...

Page 19: ...155 1100 1044 992 938 D 1323 1270 1213 1156 1104 1052 993 933 880 821 Low Heat A 1594 1553 1507 1462 1415 1369 1321 1274 1223 1178 B 1323 1270 1213 1156 1104 1052 993 933 880 821 C 1181 1118 1049 980 913 857 795 743 696 640 D 1025 950 868 788 713 654 591 505 458 415 60125 Continuous Fan A 2077 2043 2006 1961 1922 1880 1836 1789 1744 1696 B 1879 1843 1807 1763 1723 1679 1635 1590 1536 1493 C 1683 1...

Page 20: ... 02 0 01 0 06 900 0 03 0 01 0 08 1000 0 04 0 01 0 10 1100 0 05 0 01 0 13 1200 0 06 0 02 0 16 1300 0 07 0 03 0 17 1400 0 08 0 04 0 18 042 3 5 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08 1800 0 08 0 04 0 09 1900 0 09 0 05 0 10 2000 0 09 0 05 0 11 048 4 0 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0...

Page 21: ...REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324 001 UNIT TYPICAL SLAB ON GROUND INSTALLATION A0325 001 SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPLY LINE MANUAL GAS SHUTOFF VAVLE CONDENSATE DRAIN ...

Page 22: ...Measure the supply air static pressure Record this positive number Measure the return air static pressure Record this negative number Treat the negative number as a positive and add the two numbers together This is total system static UNIT TYPICAL ROOF CURB INSTALLATION SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPL...