505428-YTG-V-0417
26
Johnson Controls Unitary Products
115°F
125°F
3750
77
148.6
15.3
73.8
57.6
41.4
-
-
-
134.2
17.0
69.2
53.1
36.9
-
-
-
72
138.6
15.1
97.6
81.4
65.3
49.1
-
-
128.0
16.7
93.8
77.6
61.5
45.3
-
-
67
128.6
14.8
121.5
105.3
89.1
72.9
56.7
-
121.7
16.3
118.3
102.2
86.0
69.9
53.7
-
62
119.7
14.5
119.7
119.7
114.2
98.0
81.8
65.7
111.5
16.0
111.5
111.5
110.2
94.1
77.9
61.8
57
123.4
14.7
123.4
123.4
109.0
92.8
76.7
60.5
115.7
16.3
115.7
115.7
101.5
85.3
69.2
53.0
4375
77
155.4
15.4
88.5
64.6
45.9
-
-
-
142.1
17.0
86.4
60.4
41.5
-
-
-
72
145.0
15.1
109.7
91.0
72.3
53.6
-
-
135.4
16.6
106.7
87.8
68.9
50.0
-
-
67
134.5
14.8
130.9
117.4
98.7
80.0
61.2
-
128.7
16.3
127.0
115.2
96.4
77.5
58.6
-
62
125.3
14.5
125.3
125.3
126.5
107.8
89.0
70.3
118.0
16.0
118.0
118.0
118.0
105.0
85.7
66.8
57
129.1
14.7
129.1
129.1
120.7
102.0
83.3
64.6
122.4
16.3
122.4
122.4
113.8
95.2
76.0
57.1
5000
77
162.3
15.4
103.2
71.6
50.3
-
-
-
150.0
16.9
103.5
67.6
46.0
-
-
-
72
151.3
15.1
121.8
100.6
79.3
58.0
-
-
142.8
16.6
119.6
98.0
76.3
54.7
-
-
67
140.4
14.8
140.4
129.5
108.3
87.0
65.7
-
135.6
16.3
135.6
128.3
106.7
85.1
63.5
-
62
130.8
14.5
130.8
130.8
138.8
117.5
96.2
75.0
124.4
16.0
124.4
124.4
124.4
115.8
93.5
71.9
57
134.8
14.7
134.8
134.8
132.5
111.2
90.0
68.7
129.0
16.2
129.0
129.0
126.0
105.2
82.8
61.2
5625
72
154.3
15.2
133.5
110.3
87.0
63.8
-
-
144.6
16.7
130.8
107.3
83.8
60.3
-
-
67
143.2
14.9
143.2
137.8
118.8
95.5
72.3
-
137.4
16.4
137.4
134.1
117.1
93.6
70.1
-
62
133.4
14.6
133.4
133.4
137.4
114.1
90.8
67.6
126.0
16.1
126.0
126.0
126.0
109.0
85.1
61.6
57
137.4
14.8
137.4
137.4
136.3
113.0
89.8
66.5
130.7
16.3
130.7
130.7
129.2
106.1
82.2
58.7
6250
72
157.3
15.3
145.3
120.0
94.7
69.5
-
-
146.4
16.8
142.0
116.6
91.2
65.8
-
-
67
146.0
15.0
146.0
146.0
129.3
104.1
78.8
-
139.2
16.5
139.2
139.2
127.5
102.1
76.7
-
62
136.0
14.7
136.0
136.0
136.0
110.7
85.4
60.2
127.6
16.2
127.6
127.6
127.6
102.2
76.8
51.4
57
140.1
14.9
140.1
140.1
140.1
114.8
89.6
64.3
132.4
16.5
132.4
132.4
132.4
107.0
81.6
56.2
1
These capacities are gross ratings. For net capacity, deduct supply air blower motor, MBh. Example: Refer to the appropriate Blower
Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746
nameplate rated motor
efficiency.
2
These ratings include the condenser fan motors and the compressor motors but not the supply air blower motor.
YD150/ND180/NM180
(Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65
Summary of Contents for NC090-300
Page 73: ...505428 YTG V 0417 Johnson Controls Unitary Products 73 Typical YC120 150 Wiring Diagram...
Page 74: ...505428 YTG V 0417 74 Johnson Controls Unitary Products Typical YD120 150 Wiring Diagram...
Page 75: ...505428 YTG V 0417 Johnson Controls Unitary Products 75 Typical YC180 Wiring Diagram...
Page 76: ...505428 YTG V 0417 76 Johnson Controls Unitary Products Typical YC240 Wiring Diagram...
Page 77: ...505428 YTG V 0417 Johnson Controls Unitary Products 77 Typical YC300 Wiring Diagram...
Page 78: ...505428 YTG V 0417 78 Johnson Controls Unitary Products Typical YD180 240 Wiring Diagram...
Page 80: ...505428 YTG V 0417 80 Johnson Controls Unitary Products Typical PC120 Wiring Diagram...
Page 81: ...505428 YTG V 0417 Johnson Controls Unitary Products 81 Typical PC180 Wiring Diagram...
Page 82: ...505428 YTG V 0417 82 Johnson Controls Unitary Products Typical PD180 240 Wiring Diagram...