TIMER OPERATING MODES

I. TIMER  ON

This mode enables you to set a start operating time
Press the TIMER button till the ON sign blinks. Start
time can be adjusted using up and down buttons
respectively. Press SET button to activate the timer.

Example: Operation is restored at 10:30.

(continued)

II. TIMER  OFF

This mode enables you to set the stop time of operation.
Press the TIMER button till the OFF sign blinks. Time
can be adjusted using up and down button respectively.
Press SET button to activate the timer.

Example: Operation stops at 18:00

IV. CLEAR

Use this mode to cancel timer operation. Press CLEAR
button, timer operation will terminate and the LCD
display will be cleared for each timer mode.

Note: If TIMER button is selected and neither time adjust, SET, or

CLEAR buttons are pressed within 15 seconds, the timer
operation will be cancelled and the last set-up will be
displayed.

III. TIMER ON AND OFF

This mode enables you to set the start and stop time of
operation. Press the TIMER button till the ON sign blinks.
By pressing again the OFF sign blinks. Time can be
adjusted by using the up and down buttons, respectively.
Press SET button to activate the timer. The LCD display
will show the current time.

Example: Operation is restored at 10:30 and stops at 18:00

OFF

ON

OFF

ON

Note:

After pressing SET button the LCD will display the current time.

03_MHC/BOH 07-25.p65

18/3/02, 16:15

15

Summary of Contents for MHC-MHH/BOC-BOH 07

Page 1: ...MINISPLIT HIGH WALL AIR CONDITIONER MODELS MHC MHH BOC BOH 07 MHC MHH BOC BOH 09 MHC MHH BOC BOH 12 MHC MHH BOC BOH 18 MHC MHH BOC BOH 25 035T79000 000 Owner s Manual ...

Page 2: ...ighbours from noises 5 Electrical work 5 System relocation 5 Name of Parts 6 Indoor unit 6 Outdoor unit 6 Remote control 7 Use of Wireless Remote Control 11 Operation Procedure 12 Maintenance 17 Before maintenance 17 Cleaning the unit 17 Cleaning the air filter 18 Replacement of air purifying filter 18 Before Calling for Service 19 QUALITY POLICY We will continuously strive to satisfy our customer...

Page 3: ... Do not expose your body directly to the cool or hot air for prolonged period do not cool or hot the room too much This could effect your physical condition and cause health problems Do not put a finger a rod or other objects into the air outlet or inlet As a fan is rotating at a high speed it will cause injury Do not attempt to repair relocate modify or reinstall the air conditioner by yourself I...

Page 4: ...r damage Do not wash the unit with water Do not place a vessel containing water on the unit Do not stand or sit on the outdoor unit do not place any object on the unit Do not place a burning appliance in a place exposed to the air flow form the unit or under the indoor unit Ventilate the room from time to time Be careful especially when using a burning appliance in the same room Insufficient venti...

Page 5: ...and skills Please consult the shop where you bought the air conditioner if relocation is necessary for moving or remodelling _ _ _ _ _ WARNING The air conditioner must be earthed in accordance with the local codes Do not install the air conditioner in places where flammable gas may leak Incomplete earthing may result in electric shock Do not connect the earth line to a gas pipe lightening rod or a...

Page 6: ...des OUTDOOR UNIT A Air Outlet B Air Inlet C Refrigerant gas piping E Air Outlet F Air Filter G Air Inlet H Louver Horizontal Blades D Refrigerant liquid piping E Additional drain hose F Connecting Cable B A F E D C POWER ON OFF POWER ON OFF POWER ON OFF POWER ON OFF POWER ON OFF EMERGENCY OPERATION A B C D E F G H ...

Page 7: ... Room temperature UP button F TIMER CLEAR button G TIMER UP button H TIMER DOWN button I START STOP button J TIMER button K TIMER SET button L Operation MODE selection button COOLING HEATING AUTO COOL HEAT DRY FAN M Room temperature DOWN button N SLEEP button O Transmission sign TEMP OFF ON MODE C C C SET CLEAR TIMER A B C D E F G H I J K L M N O continued ...

Page 8: ...to be used when temperature is rather low but the humidity is high FAN Recirculates and filters the room air Maintains constant air movement AUTO FAN The air conditioner automatically selects the FAN speed in accordance with the room temperature At the start the unit operates at high fan speed As the room air approaches to the desired temperature the fan switches to a lower speed for quieter opera...

Page 9: ... SLEEP mode the air conditioner will be automatically turned off after seven hours The result is a more comfortable and invigorating sleep which leaves you feeling fresh and energetic in the morning AUTO LOUVER The air louver is automatically positioned for the most suitable blow out angle when COOL HEAT DRY or FAN modes are selected When the air conditioner is turned off the louver will close aut...

Page 10: ...hout the use of the remote control 3 MIN DELAYED RUN The compressor is protected by a three minute delayed restart MEMORY The microprocessor retains the last data entry whether or not the unit is plugged in Therefore when the unit restarts after a power distruption or failure it will resume operating in the same mode as before the power was disrupted LOCK Freezes the last operation setting on the ...

Page 11: ...ng between the remote control and the signal receptor Do not drop or throw the remote control Do not place the remote control in a location exposed to direct sunlight or next to a heating unit and or other heat source Do not expose the air conditioner signal receiver to a strong light such as fluorescent lamp or sunlight REMOTE CONTROL BATTERY CHANGE Remove the batteries from the remote control as...

Page 12: ... speed by pressing FAN SPEED button COOLING OPERATION Select the COOLING mode by pressing MODE button Switch to the desired FAN SPEED or to AUTO FAN by pressing button Select suitable temperature setting By selecting the COOLING mode the air flap will move automatically to air delivery position optimal for cooling COOLING OPERATION WITH AUTO FAN MODE This operation starts with the highest air flow...

Page 13: ...e desired FAN SPEED or to AUTO FAN by pressing button Select suitable temperature setting The air flap will automatically move to either horizontal air delivery for cooling or to vertical air delivery for heating At start the air conditioner will select its mode of operation according to the room temperature and the termperature setting DRY OPERATION Select the DRY mode by pressing MODE button Sel...

Page 14: ...press on one of the following START STOP button SLEEP button TIMER OPERATION Press TIMER button to activate the timed operation mode Each time the TIMER button is pressed one of the following four types of operation modes will appear on the LCD display The operation modes are sequenced in the direction of arrow TIMER indicator on the air conditioner will light up during TIMER operation Note After ...

Page 15: ...cancel timer operation Press CLEAR button timer operation will terminate and the LCD display will be cleared for each timer mode Note If TIMER button is selected and neither time adjust SET or CLEAR buttons are pressed within 15 seconds the timer operation will be cancelled and the last set up will be displayed III TIMER ON AND OFF This mode enables you to set the start and stop time of operation ...

Page 16: ...D will display the clock time The last operating set up will be kept for the next operation CURRENT CLOCK TIME SET Clock setting is performed when batteries are inserted The remote control displays the setting and the clock display will blink 0 00 or 12 00 AM AM sign will blink too till a new time is set For clock setting use TIMER UP buttons and TIMER DOWN buttons for setting the hours and minute...

Page 17: ...are designed to operate for long periods of time with a minimum of maintenance However the following operation must be performed regularly BEFORE MAINTENANCE _ _ _ _ _ Turn off the main breaker or disconnect the main power supply Notes Don t spill water There is a danger of electric shock Don t used petrol paint thinner benzene or polishing agents They may deform or scratch the unit CLEANING THE U...

Page 18: ...CY OPERATION Air purifying filter If the air purifying filter is clogged it may lower the unit s capacity or cause condensation at air outlet The air purifying filter is disposable The standard usable interval is about 4 mounts However if the color of the filter turns dark brown replace it at once CLEANING THE AIR FILTER 1 Remove the air filter Lightly hold the knobs at both sides and lift a littl...

Page 19: ...d signal does not 1 Check for obstruction to remote control command reach unit between unit and remote control Clear if needed 2 Distance between remote 2 Get closer to unit control and unit too large or aimed at form improper angle 3 Infra Red receiver on unit 3 Dim lights fluorescents especially exposed to strong light source D Air does not blow out from 1 De icing protection mode is 1 Normal op...

Page 20: ...m each system of the unit into a suitable container using a refrigerant reclaim or recovery unit This refrigerant may then be re used if appropriate or returned to the manufacturer for disposal Under No circumstances should refrigerant be vented to atmosphere Where appropriate drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulation...

Reviews: