![York MFSI Manual Download Page 28](http://html1.mh-extra.com/html/york/mfsi/mfsi_manual_3560852028.webp)
YORK® MIXED FLOW, INLINE FAN, MODEL MFSI
28
90% WOV
80% WOV
70% WOV
60% WOV
1/3 HP
1/2 HP
3/4 HP
1 HP
1 1/2 HP
2 HP
10 HP
3 HP
5 HP
7 1/2 HP
1300
1500
1700
1900
1900
2100
2300
2500
2700
System curve, do not select to the left.
3111
Static
Pressure
(inches
W
.G.)
CFM x 1000
SOUND POWER LEVELS
SOUND POWER LEVELS
The sound power level ratings shown are in decibels, referred to 10
-12
watts calculated per AMCA Standard 301. Values shown are for inlet Lwi and LwiA sound power
levels for Installation Type B: free inlet, ducted outlet. Ratings do not include the effects of duct end correction.
Size 165
Inlet Sound Power (Lwi)
RPM
%WOV
1
2
3
4
5
6
7
8
LwiA
RPM
%WOV
1
2
3
4
5
6
7
8
LwiA
734
100
71
73
76
77
72
61
53
45
77
2100
100
82
88
95
91
91
88
83
73
95
80
70
73
76
77
72
63
54
45
77
80
80
86
92
89
89
88
82
75
94
70
71
73
76
78
72
63
55
46
78
70
81
85
90
88
89
87
81
75
93
60
71
73
76
78
73
63
55
46
78
60
81
85
89
87
89
87
81
75
93
50
71
73
76
78
72
63
55
46
78
50
82
84
88
86
89
87
81
75
93
1000
100
83
80
82
84
84
72
64
56
86
2300
100
83
89
98
93
93
90
86
75
98
80
82
80
82
84
84
73
65
56
86
80
80
87
93
91
91
90
84
77
96
70
82
80
82
85
84
73
65
56
87
70
81
86
92
89
90
89
83
77
95
60
82
80
82
85
85
73
66
57
87
60
82
85
91
88
90
89
83
77
94
50
83
80
82
85
84
73
66
57
87
50
83
85
89
87
90
89
83
77
94
1300
100
83
84
85
86
86
79
70
63
89
2500
100
85
91
99
96
95
92
88
79
100
80
82
83
85
86
85
79
71
63
88
80
82
88
95
93
92
92
86
80
98
70
82
83
84
86
86
79
71
63
89
70
83
88
93
91
92
91
86
80
97
60
82
82
84
86
86
79
71
63
89
60
83
87
93
91
91
91
86
80
96
50
82
82
84
86
86
79
71
63
89
50
84
87
90
90
91
91
86
80
96
1500
100
83
86
86
87
87
82
73
66
90
2700
100
86
92
100
98
96
94
90
81
101
80
82
85
86
87
86
81
74
66
90
80
83
90
96
95
94
93
89
82
99
70
83
84
85
86
87
81
74
67
90
70
84
89
94
94
93
93
88
82
99
60
83
83
84
86
87
81
74
67
90
60
85
89
94
93
93
93
88
82
98
50
83
83
84
86
87
81
74
66
90
50
86
89
92
92
93
93
88
82
98
1700
100
82
87
88
88
88
84
77
69
92
2900
100
87
94
101
100
98
96
92
84
103
80
82
86
87
87
87
83
76
69
91
80
84
91
97
97
96
95
91
84
101
70
83
84
86
87
88
83
76
69
91
70
86
91
96
96
95
95
90
84
101
60
83
84
85
86
88
83
76
69
91
60
86
91
95
95
94
94
90
84
100
50
83
83
85
86
88
83
76
69
91
50
87
91
93
93
94
94
90
84
99
1900
100
82
88
91
90
90
86
80
71
94
3111
100
88
95
102
103
99
98
94
87
105
80
81
86
90
88
88
85
79
72
92
80
86
92
98
99
97
97
93
87
103
70
82
85
88
87
88
85
79
72
92
70
87
92
97
98
96
96
93
86
102
60
82
85
87
87
88
85
79
72
92
60
87
92
96
97
96
96
92
86
102
50
82
84
86
86
88
85
79
72
92
50
88
92
95
95
95
96
92
86
101