Wiring

Prepare the power source for exclusive with the air conditioner.
The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation.

Remark:

  All the wiring must be based on the wiring nameplate which shown on the model.

• Perform the wiring with sufficient capacity. Installation places legally require a short circuit isolator to be attached to

prevent electrical shock.

• Do not extend the power cable code by cutting.
• Power voltage should in the range of 90%~110% of rated voltage.
• The plug of the air conditioner takes a grounding leg, so clients should use a grounding socket so that the air

conditioner can be grounded efficiently.

• If the power cord is damaged, replacement should be conducted by qualified technician or a serviceman.

  

Note

    Remark per EMC Directive 89/336/EEC

For to prevent flicker impressions during the start of the compressor (technical process), following installation conditions do apply.
1. The power connection for the air conditioner has to be done at the main power distribution.

The distribution has to be of an low impedance, normally the required impedance reaches at a 32 A fusing point.

2. No other equipment has to be connected with this power line,.
3. For detailed installation acceptance, please refer to your contract with the power supplier if restrictions do apply for

products like washing machines, air conditioner or electrical ovens.

4. For power details of the air conditioner, refer to the rating plate of the product.
5. For any question contact your local dealer.

  

Cautions

• Never modify the unit by removing any of the safety guards or by bypassing any of the safety interlock swithces.
• Connect the connecting cable correctly and connect the connecting cable to terminal as identified with their respective marks.
• Do not scratch the conductive core & inner insulator of power supply cables and do not deform or smash on the surface of cables.

   Electrical Connections

All electrical wiring and connections must comply with local codes and standards. Power supply cord and interconnection
cord used must not be lighter than Polychloroprene sheeted cord (245 IEC 57 or H05RN-F).
Disconnecting device must have a contact separation of at least 3 mm.

Model : 07-21 (Cooling only)

Power supply

220-240V/1Ph/50Hz

220-230V/1Ph/60Hz

Indoor

L

N

1

2(N)

1

2(N)

Outdoor

NOTE

CAUTIONS

CAUTIONS

Model : 07-21 (Cooling and Heating)

Power supply

220-240V/1Ph/50Hz

220-230V/1Ph/60Hz

L

N

1

2(N)

3

4

1

2(N)

3

4

Outdoor

Indoor

1

2

3

4

N

L

1

2

3

4

1

2(N) S

1

2(N) S

N

L

Model : 09-12 115V, 60Hz (UL) (Cooling only)

Model : 18-24 220-230V, 60Hz (UL) (Cooling only)

Power supply

Indoor

Outdoor

Indoor

Outdoor

115V/1Ph/60Hz

Power supply

115V/1Ph/60Hz

J174_lastRev4.pmd

3/14/05, 3:27 PM

12

Summary of Contents for HLCA-HLHA 07-36

Page 1: ...er s Manual MODELS HLCA HLHA 07 36 HECB HEHB 07 30 MINISPLIT HIGH WALL AIR CONDITIONER EN035M80000 000 The units comply with one or more of the following marks see unit for details J174_lastRev4 pmd 3...

Page 2: ...Quality POLICY We will continuously strive to satisfy our customers with consistent reliability in product service and support through superior quality service culture and distinctive technology R22...

Page 3: ...n which may be dangerous and can cause injury Installation and maintenance of this air conditioning system should only be carried out by trained and qualified personnel After unpacking please check th...

Page 4: ...play panel Active Carbon Electrostatic Fiber Filter Standard DISPLAY PANEL OPERATION Indicator The indicator flashes once every second after power is on and illuminates when the air connditioner is in...

Page 5: ...UTO mode it will automatically select cooling heating cooling heating models only or fan only operation depending on what temperature you have selected and the room temperature The air conditioner wil...

Page 6: ...and the main breaker capacity are sufficient and the installation area is sufficient and complies with the requirements Check that the power supply available agrees with name plate voltage Electrical...

Page 7: ...0 62 590 750 HLDA HLJA 07 09 HEDB HEJB 07 09 HLDA HLJA 12 HEDB HEJB 12 HLDA HLJA 09 12 115V 60Hz UL HLDA HLJA 18 HEDB HEJB 18 HLDA HLJA 21 30 HEDB HEJB 21 30 HLDA HLJA 18 220 230V 60Hz UL HLDA HLJA 36...

Page 8: ...position Drill a hole and mount installation plate After determining the pipe hole position drill the hole at a slight downward slant towards the outdoor side 65 mm Outdoor Indoor Note When installing...

Page 9: ...the left or the right side Verification of condensate water drainage Fill the drain pan with water and observe evacuation Note Do not put the drain hose end into water Drain hose For left and left rea...

Page 10: ...Fix piping with pipe clamps and check that any pipe vibrations cannot be transmitted to the building structure Connect the pipe correctly Do not apply the excessive torque Use an appropriate bending...

Page 11: ...iping length of 5 meters Liquid Cooling GAS Cooling suction Low pressure High pressure Manifold Gas valve Liquid valve Pressure tap Outdoor Unit Indoor Unit Gas Line Liquid Line R22 R407C Outdoor heat...

Page 12: ...n acceptance please refer to your contract with the power supplier if restrictions do apply for products like washing machines air conditioner or electrical ovens 4 For power details of the air condit...

Page 13: ...t Indoor Outdoor Indoor Outdoor Power supply 380 415V 3Ph 50Hz 430V 3Ph 60Hz Power supply 380 415V 3Ph 50Hz 430V 3Ph 60Hz Wiring Connection Model 07 21 Indoor Outdoor To outdoor unit Cooling Heating t...

Page 14: ...A N A N Cooling Heating type Cooling only type Cord clamp Terminal block of indoor unit Terminal block of indoor unit Cooling only type Cooling Heating type Cord clamp Terminal block of outdoor unit...

Page 15: ...ill switch to defrosting mode when either of the following conditions is met a Unit has been running under T3 0o C for 40 minutes and T3 3o C for 3 minutes b Unit has been running at high temperature...

Page 16: ...the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or servicer Checks before operation Check...

Page 17: ...nit This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell come out from the indoor unit This is caused by the indoor...

Page 18: ...ulate them separately together 3 The room was probably very hot 3 Wait while unit has enough time to cool when you star ted the cool the room system D The compressor run continuously 1 Thermostat adju...

Page 19: ...1370 1220 1740 1850 1900 2250 2450 2250 2450 2400 2450 2400 2450 220 240 1 50 or 380 415 3 50 1 1 1 1 1 1 1 1 380 350 320 450 420 390 550 500 460 750 710 650 800 760 700 1050 950 850 1150 1050 950 13...

Page 20: ...1 1 1 1 1 1 1 1 1 1 1 1 1 1 Rotary Scroll 535 540 590 695 700 780 760 845 235 250 285 335 27 28 32 30 34 36 43 44 50 55 58 60 67 69 3 8 1 2 5 8 1 4 1 4 3 8 Flare Nut Wireless Control with LCD Display...

Page 21: ...tions Ultra R22 60Hz UL Outdoor Unit Indoor Unit Wireless Control with LCD Display R22 HLDA HLJA HLDA09 HLDA12 HLDA18 HLDA24 HLEA HLKA HLEA09 HLEA12 HLEA18 HLEA24 115 1 60 220 230 1 60 115 1 60 220 23...

Page 22: ...6 330 750 906 1080 188 235 222 8 5 13 5 17 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 Rotary Scroll 535 540 590 695 700 780 760 845 235 250 285 335 29 30 28 29 34 36 41 41 52 55 61 62 63 64 63 64 3 8 1 2 5 8 1 4 1...

Page 23: ...unit installation instructions for unit weight and correct methods of lifting Note that any residual or spilt refrigerant oil should be mopped up and disposed of as described above 4 4 4 4 4 After re...

Reviews: