036-21323-002-C-0206
14
Unitary Products Group
TABLE 16: 15 TON CAPACITY TABLE - 105° AND 115°F
15 Ton Capacity Tables
HB180 Matched with LB180
AIR ON EVAPORATOR
OUTDOOR AMBIENT TEMPERATURE (F):
105
°
CFM
W.B.
GROSS
INPUT
86
GROSS SENSIBLE CAPACITY (MBh)
TEMP
CAP.
POWER
(RETURN AIR DRY BULB TEMP.- (F)
(F)
(MBh)
(kW)
83
80
77
74
71
68
4500
72
182.8
18.89
111.9
99.1
86.2
73.4
60.6
#N/A
#N/A
67
168.9
18.42
139.2
126.3
113.5
100.7
87.8
75.0
62.2
62
156.1
18.00
156.1
150.4
137.6
124.7
111.9
99.1
86.2
57
157.8
17.99
157.8
152.5
139.7
126.8
114.0
101.2
88.3
5250
72
187.6
19.03
123.6
108.5
93.3
78.1
63.0
#N/A
#N/A
67
173.4
18.56
153.1
137.9
122.8
107.6
92.4
77.3
62.1
62
160.2
18.13
160.2
157.4
148.8
133.6
118.5
103.3
88.1
57
162.0
18.13
162.0
159.3
151.1
135.9
120.7
105.6
90.4
6000
72
192.4
19.17
135.3
117.8
100.3
82.8
65.3
#N/A
#N/A
67
177.8
18.70
167.0
149.5
132.0
114.6
97.1
79.6
62.1
62
164.3
18.27
164.3
164.3
160.0
142.5
125.0
107.5
90.1
57
166.1
18.26
166.1
166.1
162.5
145.0
127.5
110.0
92.5
6750
72
196.1
19.23
146.1
126.2
106.2
86.3
66.4
#N/A
#N/A
67
181.2
18.76
175.9
159.8
139.8
119.9
100.0
80.1
60.1
62
167.5
18.33
167.5
167.5
165.4
145.4
125.5
105.6
85.7
57
169.3
18.32
169.3
169.3
167.5
147.6
127.7
107.7
87.8
7500
72
199.8
19.30
156.9
134.5
112.2
89.8
67.4
#N/A
#N/A
67
184.7
18.82
184.7
170.0
147.6
125.3
102.9
80.5
58.2
62
170.7
18.39
170.7
170.7
170.7
148.3
126.0
103.6
81.3
57
172.5
18.38
172.5
172.5
172.5
150.2
127.8
105.5
83.1
Indicates Nominal Capacity Rating Point.
INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR
15 Ton Capacity Tables
HB180 Matched with LB180
AIR ON EVAPORATOR
OUTDOOR AMBIENT TEMPERATURE (F):
115°
CFM
W.B.
GROSS
INPUT
86
GROSS SENSIBLE CAPACITY (MBh)
TEMP
CAP.
POWER
(RETURN AIR DRY BULB TEMP.- (F)
(F)
(MBh)
(kW)
83
80
77
74
71
68
4500
72
174.7
20.88
109.7
96.8
84.0
71.2
58.3
#N/A
#N/A
67
161.0
20.33
136.1
123.3
110.5
97.6
84.8
72.0
59.1
62
149.4
19.81
149.4
147.6
134.8
122.0
109.1
96.3
83.5
57
152.5
19.88
152.5
146.9
134.1
121.2
108.4
95.6
82.8
5250
72
179.0
21.06
121.1
105.9
90.8
75.6
60.4
#N/A
#N/A
67
165.0
20.51
149.7
134.5
119.3
104.2
89.0
73.9
58.7
62
153.1
19.99
153.1
152.2
145.6
130.5
115.3
100.1
85.0
57
156.2
20.05
156.2
153.4
144.8
129.7
114.5
99.4
84.2
6000
72
183.3
21.25
132.5
115.0
97.5
80.0
62.5
#N/A
#N/A
67
168.9
20.69
163.2
145.7
128.2
110.7
93.2
75.7
58.2
62
156.8
20.16
156.8
156.8
156.5
139.0
121.5
104.0
86.5
57
159.9
20.23
159.9
159.9
155.6
138.1
120.6
103.1
85.6
6750
72
187.1
21.30
143.8
123.9
103.9
84.0
64.1
#N/A
#N/A
67
172.4
20.73
169.6
156.6
136.7
116.8
96.8
76.9
57.0
62
160.0
20.21
160.0
160.0
159.9
139.9
120.0
100.1
80.2
57
163.2
20.27
163.2
163.2
161.1
141.2
121.2
101.3
81.4
7500
72
190.9
21.34
155.1
132.7
110.4
88.0
65.7
#N/A
#N/A
67
175.9
20.78
175.9
167.5
145.1
122.8
100.4
78.1
55.7
62
163.3
20.25
163.3
163.3
163.3
140.9
118.5
96.2
73.8
57
166.6
20.32
166.6
166.6
166.6
144.2
121.8
99.5
77.1
Indicates Nominal Capacity Rating Point.
INPUT POWER INCLUDES THE CONDENSER AND COMPRESSOR MOTORS BUT NOT THE INDOOR BLOWER MOTOR