COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL

1

MODEL

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED 

CFM

NET MBH

SEER

W/O TXV

SEER

+ TXV

3

EER

TOTAL SENS.

1 PH 10 SEER AC WITH N1AH / G2FD

H1RA018S06

N1AHB0806

2,5,8,10

17

G2FD024(S,H)17

650

19.0

14.1

10.50

-

9.80

H1RA024S06

N1AHB0806

2,5,8,10

17

G2FD024(S,H)17

800

24.4

18.1

10.50

-

9.55

N1AHB0806

2,5,8,10

17

G2FD030(S,H)17

850

25.0

18.5

10.60

-

9.65

H2RA030S06

N1AHB1206

5,8,10,15,19

17

G2FD030(S,H)17

1000

29.0

21.5

10.30

-

9.45

N1AHB1206

5,8,10,15,19

17

G2FD036(S,H)17

1000

30.0

22.2

10.50

-

9.65

H2RA036S06

N1AHB1206

5,8,10,15,19

17

G2FD036(S,H)17

1200

33.8

25.0

10.00

-

9.20

N1AHB1206

5,8,10,15,19

17

G2FD046(S,H)17

1200

34.4

25.5

10.15

-

9.30

H1RA042S06

N1AHC1606

5,8,10,15,20

21

G2FD042(S,H)21

1400

39.5

29.2

10.00

-

9.00

N1AHC1606

5,8,10,15,20

21

G2FD048(S,H)21

1450

41.0

30.3

10.10

-

9.15

H1RA048S06

N1AHC1606

5,8,10,15,20

21

G2FD048(S,H)21

1600

46.0

34.0

10.10

-

9.50

N1AHD2006

8,10,15,20,25,30

24

G2FD060(S,H)24

1600

47.0

34.8

10.40

-

9.70

H3RA060S06

N1AHD2006

8,10,15,20,25,30

24

G2FD060(S,H)24

1800

56.0

40.2

10.50

-

9.35

3 PH 10 SEER AC WITH N1AH / G2FD

H1RA036 S(25,46)

N1AHB1246

10,15

21

G2FD036(S,H)17

1200

33.8

25.0

10.00

-

9.20

N1AHB1246

10,15

21

G2FD042(S,H)21

1400

40.0

30.1

10.00

9.05

H1RA042S(25,46)

N1AHC1646

10,15

21

G2FD042(S,H)21

1400

39.5

29.2

10.00

-

9.00

N1AHC1646

10,15

24

G2FD048(S,H)21

1450

41.0

30.3

10.10

-

9.15

H1RA048S(25,46)

N1AHC1646

10,15

21

G2FD048(S,H)21

1600

46.0

34.0

10.10

-

9.50

N1AHD2046

10,15,29

24

G2FD048(S,H)24

1600

24.6

34.0

10.10

-

9.50

N1AHD2046

10,15,29

24

G2FD048(S,H)24

1600

46.0

34.0

10.10

-

9.50

H1RA060S(25,46)

N1AHD2046

10,15,29

24

G2FD060(S,H)24

1750

58.5

39.8

10.00

-

10.25

1 PH 10 SEER AC / F2RP / RC / FC 

4

,

5

H1RA018S06

F2RC/F2FC024

5,8,10

18

-

650

17.4

12.9

10.00

-

9.00

F2RP/F2FP018

2,5,8

18

-

650

17.4

12.3

10.00

-

9.00

F2RP/F2FP024

5,8,10

18

-

650

17.4

12.9

10.00

-

9.00

H1RA024S06

F2RP/F2FP024

5,8,10

18

-

800

23.4

17.3

10.00

-

9.00

F2RP/F2FP030

5,8,10,15

18

-

800

23.6

17.5

10.00

-

9.10

H2RA030S06

F2RP/F2FP030

5,8,10,15

18

-

1000

28.4

21.0

10.00

-

9.50

F2RP/F2FP036

5,8,10,15,19

21

-

1000

28.0

20.0

10.00

-

9.00

H2RA036S06

F2RC/F2FC036

5,8,10,15

21

-

1200

33.6

21.5

10.00

-

9.10

F2RP/F2FP036

5,8,10,15,19

21

-

1200

34.4

25.2

10.20

-

9.30

F2RP/F2FP042

5,8,10,15

21

-

1200

34.4

25.2

10.15

-

9.20

H1RA042S06

F2RP/F2FP042

5,8,10,15

21

-

1400

39.5

28.9

10.00

-

9.00

F2FP048

5,8,10,15,20,25

24

-

1400

40.5

30.0

10.00

-

9.20

H1RA048S06

F2FP048

5,8,10,15,20,25

24

-

1600

45.5

33.7

10.00

-

9.15

F2FP060

5,8,10,15,20,25

24

-

1600

46.5

34.4

10.00

-

9.70

H3RA060S06

F2FP060

5,8,10,15,20,25

24

-

1800

56.0

41.0

10.00

-

9.15

3 PH 10 seer AC with F2RP / FP

H1RA036 S(25,46)

F2RC/F2FC036

5,8,10,15

21

-

1200

33.6

25.2

10.00

-

9.10

H1RA042S(25,46)

F2RP/F2FP042

5,8,10,15

21

-

1400

39.0

29.2

10.00

-

9.00

F2FP048

5,8,10,15,20,25

24

-

1400

40.5

30.4

10.00

-

9.00

H1RA048S(25,46)

F2FP048

5,8,10,15,20,25

24

-

1600

45.5

33.7

10.00

-

9.15

H1RA060S(25,46)

F2FP060

5,8,10,15,20,25

24

-

1750

58.5

39.8

10.00

-

9.80

3 PH 10 seer AC WITH 

K4EV

 

6

H1RA076S25,46

K4EV090

10,16,26,36

22

--

2600

73.5

--

--

--

10.00

H1RA090S25,46

K4EV090

10,16,26,36

22

--

3280

53.8/

89.0

--

--

--

9.63/

9.30

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240. 
Cooling MBH based on 8

0

°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

models. All ratings remain the same.

5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
6. H*BA-(T,W)090 is field convertible to two stage operation. Its IPLV = 11.2.
— = Not Applicable.

Summary of Contents for H1RA018S06

Page 1: ...OR The compressor is inter nally protected against high pressure and temperature This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect...

Page 2: ...3 6 3 11 3 14 3 15 5 4 7 5 6 2 Charge Per Foot Oz 4 0 66 0 66 0 68 0 68 0 68 0 70 070 Operating Weight Lbs 118 123 135 137 161 176 188 Physical and Electrical Data 3 Phase MODEL H1RA 036S25 H1RA 042S2...

Page 3: ...G1NA036S17J 67 67 7 G1NA036S21C 67 67 7 G1NA048S21D 78 78 0 78 4 G1NA048S24P 78 78 0 78 4 G1NA060S24T 87 96 0 G1NF024SOF 63 57 0 3 63 4 3 G1NF036SOF 67 67 7 3 G1NF048SOF 78 78 03 78 4 3 G1NF060SOF 87...

Page 4: ...tems 3 PHASE ADDITIONAL R 22 CHARGE ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS Outdoor Unit H1RA036 H1RA042 H1RA048 H1RA060 H1RA076 H1RA090 Unit Orifice s 1 67 71 73 75 78 81 81 90 Factory R 22 Charge l...

Page 5: ...7 5 10 00 9 10 H2RA030S06 F2RP F2FP030 5 8 10 15 18 1000 28 4 21 0 10 00 9 50 F2RP F2FP036 5 8 10 15 19 21 1000 28 0 20 0 10 00 9 00 H2RA036S06 F2RC F2FC036 5 8 10 15 21 1200 33 6 21 5 10 00 9 10 F2RP...

Page 6: ...0 9 55 17 G2FD030 S H 17 850 25 0 18 5 10 60 9 65 14 G2FD035 S H 14 850 25 0 18 9 10 60 9 65 17 G2FD036 S H 17 850 25 6 18 9 10 70 9 70 H2RA030S06 875 1125 14 G1FA030S14 1000 28 0 20 7 10 00 9 30 14 G...

Page 7: ...9 2 10 00 9 00 17 G2FD046 S H 17 1380 40 0 29 6 10 00 9 05 21 24 G2FD048 S H 21 24 1450 41 0 30 3 10 10 9 15 H1RA048S06 1400 1800 17 G1FA048S17 1500 44 5 33 5 10 00 9 15 21 24 G1FA048S21 1600 45 5 33...

Page 8: ...0 62 7 4 32 56 9 5 38 50 2 5 61 H2RA030S06 35 61 5 25 1 2 68 20 3 2 97 17 0 3 17 H1RA060S 25 46 35 61 5 54 4 4 46 50 5 4 74 46 3 5 08 40 68 5 27 4 2 70 23 1 3 04 19 7 3 30 40 68 5 60 1 4 44 56 0 4 83...

Page 9: ...ase for 1H 1C 1H 1C manual change over electronic non programmable thermostat 1H 1C auto manual changeover electronic programmable deluxe 7 day thermostat 1H 1C auto manual changeover electronic progr...

Page 10: ...LER TERMINAL BLOCK ROOM THERMOSTAT CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF USE COPPER CONDUCTORS ONLY TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT ALL FIELD WIRING TO BE IN ACCORDA...

Page 11: ...1 54 1 53 1 62 1 59 1 58 1 65 1 63 1 62 95 T C 19 0 17 5 15 5 19 5 18 0 16 1 19 8 18 2 16 5 S C 12 8 12 4 11 5 13 7 13 3 12 8 14 5 14 1 13 6 K W 1 97 1 91 1 90 2 02 1 96 1 95 2 05 2 00 1 99 105 T C 1...

Page 12: ...7 5 18 5 17 6 17 9 18 8 18 1 19 0 18 3 18 4 K W 2 42 2 28 2 06 2 06 2 44 2 20 2 20 2 08 2 34 2 32 2 21 1 99 105 T C 24 7 22 4 19 5 18 3 24 8 21 6 20 9 18 6 23 8 22 8 21 1 17 9 S C 16 8 16 8 15 3 16 9...

Page 13: ...2 27 1 24 4 S C 20 3 20 4 19 5 20 8 21 5 21 5 20 7 21 6 22 4 22 5 21 7 22 7 K W 3 07 2 98 2 91 2 81 3 15 3 07 3 00 2 92 3 25 3 16 3 10 2 99 105 T C 29 3 26 7 24 6 22 0 29 5 27 0 25 0 22 4 29 7 27 2 2...

Page 14: ...84 3 71 4 02 3 91 3 77 4 06 3 96 3 81 115 T C 31 0 27 6 23 5 31 1 28 2 24 2 31 3 28 5 24 4 S C 23 1 21 3 19 6 23 9 22 6 20 7 24 8 23 7 21 6 K W 4 22 4 06 3 90 4 29 4 13 3 94 4 33 4 18 4 00 125 T C 28...

Page 15: ...28 8 27 2 31 7 30 9 29 3 K W 4 58 4 44 4 30 4 74 4 60 4 47 4 89 4 77 4 64 115 T C 37 1 32 3 28 3 38 2 33 3 28 9 39 2 34 2 29 6 S C 26 8 25 1 23 3 29 0 27 2 25 4 31 1 29 4 27 4 K W 4 81 4 62 4 45 4 96...

Page 16: ...33 5 33 7 32 4 33 8 34 9 35 0 33 7 35 6 K W 4 91 4 70 4 51 4 31 5 02 4 81 4 64 4 43 5 13 4 92 4 74 4 53 105 T C 45 6 41 6 38 4 34 3 46 0 42 2 39 0 35 0 46 2 42 5 39 3 36 2 S C 30 5 30 6 29 5 30 9 32...

Page 17: ...41 2 39 2 39 7 38 2 36 5 K W 4 94 4 86 4 77 5 58 5 50 5 40 5 48 5 40 5 28 95 T C 60 9 57 3 52 7 60 4 56 0 51 5 59 9 54 7 50 3 S C 45 7 43 5 40 8 42 4 40 2 38 0 39 2 37 0 35 2 K W 6 19 6 10 6 00 6 09...

Page 18: ...58 4 55 85 T C 60 6 58 0 55 0 61 2 58 6 55 8 61 9 59 3 56 7 S C 37 6 37 3 36 5 40 2 39 9 39 1 42 8 42 5 41 7 K W 5 26 5 13 5 08 5 27 5 14 5 10 5 28 5 15 5 11 95 T C 60 0 57 4 53 7 60 7 58 5 54 8 61 4...

Page 19: ...6 18 6 15 6 58 6 48 6 46 85 T C 76 4 73 7 70 6 79 1 76 3 73 4 81 7 79 0 76 2 S C 47 9 47 6 46 8 54 7 54 4 53 5 61 5 61 2 60 3 K W 6 53 6 42 6 37 6 86 6 74 6 70 7 18 7 07 7 04 95 T C 73 8 71 1 67 2 76...

Page 20: ...8 36 8 29 8 23 85 T C 99 1 92 4 85 8 102 0 94 7 87 5 104 8 97 0 89 1 S C 72 5 67 4 62 3 74 0 68 4 62 8 75 5 69 4 63 4 K W 8 97 8 86 8 75 9 01 8 90 8 79 9 04 8 94 8 84 95 T C 94 0 87 7 81 5 95 8 89 0...

Page 21: ...DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW G2FD090 is upflow only AIR HANDLERS FOR NON FURNACE APPL...

Page 22: ...036 21121 002 Rev B 0103 22 Unitary Products Group NOTES...

Page 23: ...036 21121 002 Rev B 0103 Unitary Products Group 23...

Page 24: ...nge without notice Printed in U S A 036 21121 002 Rev B 0103 Copyright by York International Corp 2003 All rights reserved Supersedes 036 21121 002 Rev A 0602 Unitary 5005 Norman Products York OK Grou...

Reviews: