036-21339-001 Rev. C (0602)
Unitary Products Group
7
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.
a. Increase capacity 1% for each 2° increase in sub-cooling.
b. Decrease capacity 1% for each 2° decrease in sub-cooling.
3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°. Maximum recommended con-
densing temperature is 140°F.
H1RD048S06
P1XDD20V
G2FD060S24
24
1600
46.5
31.6
-
13.5
12.2
P1DUB16V
G1FA048S17
17
1460
44.5
29.3
-
13.3
12.0
P1DUB16V
G1UA048S17
17
1460
44.5
29.3
-
13.3
12.0
P1DUC20V
G1FA048S21
21
1500
45.0
30.1
-
13.5
12.2
P1DUC20V
G1UA048S21
21
1500
45.0
30.1
-
13.5
12.2
P1DUC20V
G2FD048S21
21
1500
45.5
30.7
-
13.7
12.4
P1XUC16V
G1FA048S21
21
1420
45.0
29.5
-
13.7
12.4
P1XUC16V
G1UA048S21
21
1420
45.0
29.5
-
13.7
12.4
P1XUC16V
G2FD048S21
21
1420
45.5
30.1
-
14.0
12.5
P1XUC20V
G1FA048S21
21
1450
45.0
29.6
-
13.5
12.2
P1XUC20V
G1UA048S21
21
1450
45.0
29.6
-
13.5
12.2
P1XUC20V
G2FD048S21
21
1450
45.5
30.2
-
13.7
12.3
P1XUD20V
G1FA060S24
24
1470
46.5
30.9
-
14.0
12.6
P1XUD20V
G1UA060S24
24
1470
46.5
30.9
-
14.0
12.6
P1XUD20V
G2FD048S24
24
1430
45.5
30.1
-
13.7
12.4
P1XUD20V
G2FD060S24
24
1470
46.5
30.9
-
14.0
12.6
H1RD060S06
P1XDD20V
G2FD060S24
24
1580
52.5
34.3
-
13.3
12.2
P1DUC20V
G1FA060S21
21
1630
53.0
34.9
-
13.4
12.4
P1DUC20V
G1UA060S21
21
1630
53.0
34.9
-
13.4
12.4
P1XUC20V
G1FA060S21
21
1590
53.0
34.5
-
13.3
12.4
P1XUC20V
G1UA060S21
21
1590
53.0
34.5
-
13.3
12.4
P1XUD20V
G1FA060S24
24
1560
53.0
34.4
-
13.5
12.5
P1XUD20V
G1UA060S24
24
1560
53.0
34.4
-
13.5
12.5
P1XUD20V
G2FD060S24
24
1560
53.0
34.4
-
13.5
12.5
P1XUD20V
G2FD061H24
24
1560
53.5
34.9
-
13.8
12.8
1
G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2
TXV = Use 1TV700 Series Kit.
3
Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - With Variable Speed Furnaces (Continued)
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL
MODEL
1
W
COOLING
RATED
CFM
TOTAL
CAPACITY
SENSIBLE
CAPACITY
SEER
W/O TXV
SEER
+ TXV
2
EER
COOLING PERFORMANCE
MODEL
SUCT. T/P
@ COMPR.
AIR TEMP ON CONDENSER
MODEL
SUCT. T/P
@ COMPR.
AIR TEMP ON CONDENSER
75
°
F
95
°
F
115
°
F
75
°
F
95
°
F
115
°
F
TEMP. PSIG MBH KW MBH KW MBH KW
TEMP. PSIG MBH KW MBH KW MBH KW
H1RD018S06
35
61.5
18.26
1.50
14.76
1.21
12.36
1.01
H1RD042S06
35
61.5
35.07 3.01 31.15
2.67
27.19
2.33
40
68.5
19.94
1.63
16.79
1.38
14.38
1.18
40
68.5
38.34 3.29 34.26
2.94
30.06
2.58
45
76.0
21.76
1.78
18.81
1.54
15.98
1.31
45
76.0
41.46 3.56 37.25
3.20
32.89
2.82
50
84.0
23.36
1.92
20.83
1.71
17.86
1.46
50
84.0
44.52 3.82 40.40
3.47
35.68
3.06
H1RD024S06
35
61.5
20.99
1.75
16.96
1.41
14.19
1.18
H1RD048S06
35
61.5
40.19 3.32 35.71
2.95
31.16
2.58
40
68.5
22.92
1.91
19.29
1.61
16.51
1.38
40
68.5
43.95 3.63 39.27
3.25
34.46
2.85
45
76.0
25.01
2.08
21.61
1.80
18.35
1.53
45
76.0
47.51 3.93 42.70
3.53
37.69
3.12
50
84.0
26.86
2.24
23.93
1.99
20.53
1.71
50
84.0
51.03 4.22 46.31
3.83
40.89
3.38
H1RD030S06
35
61.5
26.12
2.28
21.13
1.85
17.66
1.54
H1RD060S06
35
61.5
46.76 3.90 41.53
3.46
36.26
3.02
40
68.5
28.54
2.49
24.01
2.10
20.55
1.80
40
68.5
51.12 4.26 45.68
3.81
40.08
3.34
45
76.0
31.13
2.72
26.70
2.33
22.85
2.00
45
76.0
55.28 4.61 49.66
4.14
43.85
3.65
50
84.0
33.43
2.92
29.79
2.60
25.56
2.23
50
84.0
59.37 4.95 53.87
4.49
47.57
3.96
H1RD036S06
35
61.5
30.59
2.56
24.73
2.07
20.69
1.73
40
68.5
33.41
2.80
28.11
2.35
24.07
2.01
45
76.0
36.45
3.05
31.50
2.64
26.76
2.24
50
84.0
39.14
3.28
34.88
2.92
29.92
2.50