3.8 Vertical Swing
3.8.1 Small Horizontal Louver
After energization, vertical swing motor will firstly have the horizontal louver rotate anticlockwise to position O to close air outlet. If
swing function has not been set after startup of the unit, horizontal louver will turn clockwise to position D1 in HEAT mode. If swing
function is set when starting up the unit, the horizontal louver will swing between O and D1.There are 7 swing status of horizontal
louver: Positions O, A1, B1, C1 and D1, swing between O and D1 and stop at any position between L and D (angles between O and
D1 are equiangular). Upon turning off the unit, the horizontal louver will close at position O. Swing function is available only when
swing function is set and indoor fan is operating.
Note:
a. If the position is set between O and D1, A 1and C1 or B1 and D1 by remote controller, the horizontal louver will swing between O
and D1.
b. For model 9K/12K, only when big horizontal louver rotates to the second position for heating( 62°of corresponding angle), this louver
will be activated
.
c. Under cooling mode, this horizontal louver will be always in the position O.
3.8.2 Big Horizontal Louver
After energization, up & down swing motor will firstly have the horizontal louver rotate anticlockwise to position O to close air outlet. If
swing function has not been set after startup of the unit, horizontal louver will turn clockwise to position D in HEAT mode, or turn
clockwise to level position L in other modes. If swing function is set when starting up the unit, the horizontal louver will swing between L
and D.There are 7 swing status of horizontal louver: Positions L, A, B, C and D, swing between L and D and stop at any position
between L and D (angles between L and D are equiangular). Upon turning off the unit, the horizontal louver will close at position O.
Note: If the position is set between L and B, A and C or B and D by remote controller, the horizontal louver will swing between L and D.
3.9 Horizontal Swing
Upon energization, the vertical louver will be reset to the start position firstly and then stop in the middle position. When setting
Tamb.
T3
ć
Tpreset
Tpreset -2
ć
Mute
(0 degree)
Low
High
Med.
p
Fan s eed
O(0)
A1
B1
C1
D1
L
A
B
C
D
horizontal swing, there are 7 status: Position
ķ
, Position
ĸ
, Position
Ĺ
, Positon
ĺ
, Position
Ļ
, swing between
and
and stop at
ķ
Ļ
any position between
and
ķ
Ļ
. If setting horizontal swing during operation of the unit, the horizontal swing motor will drive the louver
to swing horizontally. When cancelling horizontal swing or it is not set when turning on the unit, the louver will stop in the current
position and it will not move when turning off the unit. Only when swing is set and indoor fan is operating, the vertical louver can
horizontally swing.
Summary of Contents for GWH12TB-S3DNA1B/I
Page 12: ...QPUVTWEVKQP 8KGYU 8QLW PP 4 5 6 0RGHO 3DQHO 0RGHOV 4 5 6 YWHJXH009BAMK FX YWHJXH012BAMK FX...
Page 13: ...QPUVTWEVKQP 8KGYU 2XWGRRU 8QLW 8QLW PP 8QLW PP 0RGHOV YWHJYH009BAMKA X 0RGHOV YWHJYH012BAMKA X...
Page 49: ...6TQWDNGUJQQVKPI QGRRU IDQ GRHV QRW RSHUDWH DC motor interface sketch...
Page 51: ...6TQWDNGUJQQVKPI XPSHU FDS PDOIXQFWLRQ Jumper cap interface sketch...
Page 53: ...6TQWDNGUJQQVKPI RPPXQLFDWLRQ PDOIXQFWLRQ Indoor unit communication indicator sketch...