(WPEVKQPCPF%QPVTQN
●
●
SLEEP BUTTON
Press this button, can select Sleep 1 ( ), Sleep 2 ( ),
Sleep 3 ( ) and cancel the Sleep, circulate between
these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status
after run for one hour , the main unit setting temperature will
increase 1
ć
,setting temperature increased 2
ć
, the unit will
run at this setting temperature; In Heat mode: sleep status after run
for one hour , the setting temperature will decrease 1
ć
, 2
hours , setting temperature will decrease 2
ć
, then the unit will
run at this setting temperature.
●
Sleep 2 is sleep mode 2, that is air conditioner will run according to
the presetting a group of sleep temperature curve.
In Cool mode:
(1) When setting the initial temperature 16-23
ć
, after turned on
Sleep function, the temperature will be increased 1
ć
in every hour,
after 3
ć
the temperature will be maintained, after 7hours,
the temperature will be decreased 1
ć
, after that the unit will keep on
running under this temperature;
(2) When setting the initial temperature 24
ć̚
2 7
ć
, after turned
on Sleep function, the temperature will be increased 1
ć
in every hour ,
after 2
ć
the temperature will be maintained, after 7hours,
the temperature will be decreased 1
ć
, after that the unit will
keep on running under this temperature;
(3) When setting the initial temperature 28
ć̚
29
ć
, after turned
on Sleep function, the temperature will be increased 1
ć
in every
hour, after 1
ć
the temperature will be maintained, after 7hours ,
the temperature will be decreased 1
ć
, after that the unit will
keep on running under this temperature;
(4) When setting the initial temperature 30
ć
, under this temper-
ature setting, after 7hours, the temperature will be decreased
1
ć
, after that the unit will keep on running under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16
ć
, it will run under
this setting temperature all along.
(2) Under the initial presetting temperature17
ć̚
20
ć
, after Sleep
function started up, the temperature will decrease 1
ć
in every
hour, after 1
ć
decreased, this temperature will be maintained.
SLEEP
Summary of Contents for GWH12TB-S3DNA1B/I
Page 12: ...QPUVTWEVKQP 8KGYU 8QLW PP 4 5 6 0RGHO 3DQHO 0RGHOV 4 5 6 YWHJXH009BAMK FX YWHJXH012BAMK FX...
Page 13: ...QPUVTWEVKQP 8KGYU 2XWGRRU 8QLW 8QLW PP 8QLW PP 0RGHOV YWHJYH009BAMKA X 0RGHOV YWHJYH012BAMKA X...
Page 49: ...6TQWDNGUJQQVKPI QGRRU IDQ GRHV QRW RSHUDWH DC motor interface sketch...
Page 51: ...6TQWDNGUJQQVKPI XPSHU FDS PDOIXQFWLRQ Jumper cap interface sketch...
Page 53: ...6TQWDNGUJQQVKPI RPPXQLFDWLRQ PDOIXQFWLRQ Indoor unit communication indicator sketch...