background image

035-14520-001 Rev.  B (0803)

12

Unitary Products Group

*

May be 0 (no breaker) or 1 (with breaker).

Table 6: 

ELECTRICAL DATA - (FOR 

SINGLE SOURCE 

POWER SUPPLY) - COPPER WIRE 1 Ø - 208/230-1-60

1

Models

F2RP/F3RP(T)/F2RC

F2FP/F3FP(T)/F2FC

Heater*

Model

Heater

Amps

240V

Field Wiring

Min. Circuit Ampacity

Max. O.C.P.

Amps/

Type

75

°

C Wire Size - AWG

208V

240V

208V

240V

208V

240V

018(N/H)06

2HK*6500206B

10.4

13.3

14.6

15

15

14

14

2HK*6500506B

20.8

24.7

27.7

25

30

10

10

2HK*6500806B

31.3

35.5

40.7

40

45

8

8

024(N/H)06

2HK*6500506B

20.8

24.7

27.7

25

30

10

10

2HK*6500806B

31.3

35.5

40.7

40

45

8

8

2HK*6501006B

41.7

46.9

53.7

50

60

8

6

030(N/H)06

2HK*6500506B

20.8

25.8

28.7

30

30

10

10

2HK*6500806B

31.3

36.7

41.7

40

45

8

8

2HK*6501006B

41.7

48.1

54.7

50

60

8

6

2HK16501506B

62.5

70.9

80.8

80

90

4

3

036(N/H)06

2HK*6500506B

20.8

26.8

29.5

30

30

10

10

2HK*6500806B

31.3

37.7

42.6

40

45

8

8

2HK*6501006B

41.7

49.1

55.6

50

60

8

6

2HK16501506B

62.5

71.9

81.6

80

90

4

3

2HK16501906B

3

73.3

83.3

95.2

90

100

3

3

040H06

2HK*6500506B

20.8

25.8

28.7

30

30

10

10

2HK*6500806B

31.3

36.7

41.7

40

45

8

8

2HK*6501006B

41.7

48.1

54.7

50

60

8

6

2HK16501506B

62.5

70.9

80.8

80

90

4

3

042(N/H)06

2HK*6500506B

20.8

28.1

30.5

30

35

10

8

2HK*6500806B

31.3

38.9

43.6

40

45

8

8

2HK*6501006B

41.7

50.3

56.6

60

60

6

6

2HK16501506B

62.5

73.2

82.6

80

90

4

3

045H06

2HK*6500506B

20.8

26.6

29.3

30

30

10

10

2HK*6500806B

31.3

37.4

42.3

40

45

8

8

2HK*6501006B

41.7

48.8

55.3

50

60

8

6

2HK16501506B

62.5

71.7

81.4

80

90

4

3

048(N/H)06

2HK*6500506B

20.8

27.6

30.2

30

35

10

8

2HK16500806B

31.3

38.4

43.2

40

45

8

8

2HK16501006B

41.7

49.8

56.2

50

60

8

6

2HK16501506B

62.5

72.7

82.3

80

90

4

3

2HK16502006B

83.3

94.9

108.3

100

110

3

2

2HK16502506B

104.2

117.7

134.3

125

150

1

1/0

060(N/H)06

2HK*6500506B

20.8

29.0

31.3

30

35

10

8

2HK16500806B

31.3

39.8

44.3

40

45

8

8

2HK16501006B

41.7

51.2

57.3

60

60

6

6

2HK16501506B

62.5

74.0

83.4

80

90

4

3

2HK16502006B

83.3

96.3

109.4

100

110

3

2

2HK16502506B

104.2

119.1

135.5

125

150

1

1/0

1.

Heat amps shown at 240V represents maximum heater rating.

2.

O.C.P. = Over Current Protection

3.

2HK16501906B only applies to F(2,3)RP and F(2,3)FP036 Models.

Summary of Contents for F2FC018

Page 1: ...S GENERAL INFORMATION 2 INSPECTION 2 REFERENCE 2 LIMITATIONS 2 LOCATION 3 HORIZONTAL DRAIN PAN INSTALLATION CONVERSION 4 DIMENSIONS DUCT CONNECTORS 5 AIR FILTERS 6 SUSPENSION KITS 6 COIL METERING DEVI...

Page 2: ...butor for more information Also check to be sure all accessories such as heater kits or suspension kits are available Installation of these accesso ries or field conversion of the unit should be accom...

Page 3: ...trapped and piped to a location that will give the occu pant a visual warning that the primary drain is clogged If the secondary drain is not used it must be capped 7 Proper electrical supply must be...

Page 4: ...fe if not previously cut out 8 Re position and replace access panels DO NOT TRY TO KNOCK OUT Models F 2 3 FP045 048 060 have a coil baffle and support bracket factory installed for right hand hori zon...

Page 5: ...s unit is not designed for non ducted freeblow applications Size outlet plenum or transition to discharge opening sizes shown in Figure 5 Duct work should be fabricated and installed in accordance wit...

Page 6: ...is a valid system match for the AC or HP unit installed The TXV is fully brazed into the coil assembly of this Air Han dler unit at the factory The temperature sensing bulb will need to be attached t...

Page 7: ...orifice with a small diameter wire or paper clip 2 Remove the new orifice from the packet and verify that it is the correct number required Install this orifice with the rounded end toward the coil a...

Page 8: ...igure 10 LOW VOLTAGE CONTROL CONNECTION The 24 volt power supply is provided by an internally wired low voltage transformer which is standard on all models However if the unit is connected to a 208 vo...

Page 9: ...OWER SUPPLY 3 GND LUG POWER SUPPLY GND LUG POWER WIRING 208 230 1 60 NOTE USE ONLY COPPER CONDUCTORS FIGURE 12 Control Board FIGURE 13 Blower Speed Connections R Y G W2 W1 O C 2 4 V A C BREAK TAB FOR...

Page 10: ...085 1100 Voltage 208 230 Amps Full Load 208 230 2 5 2 2 4 4 3 8 3 0 2 7 3 4 3 3 50 Hz 2 4 4 5 4 4 50 Hz 5 7 Locked Rotor 208 230 6 2 5 5 11 9 10 3 4 8 4 1 4 6 4 0 8 4 7 3 Filter1 Type DISPOSABLE OR PE...

Page 11: ...0 2HK 6500806B LO 5 6 7 5 19 1 25 6 3 8 5 0 5 6 7 5 5 6 7 5 2HK 6501006B LO 7 5 10 0 25 6 34 1 3 8 5 0 7 5 10 0 7 5 10 0 2HK16501506B HI 11 3 15 0 38 6 51 2 3 8 5 0 7 5 10 0 11 3 15 0 042 N H 06 2HK 6...

Page 12: ...95 2 90 100 3 3 040H06 2HK 6500506B 20 8 25 8 28 7 30 30 10 10 2HK 6500806B 31 3 36 7 41 7 40 45 8 8 2HK 6501006B 41 7 48 1 54 7 50 60 8 6 2HK16501506B 62 5 70 9 80 8 80 90 4 3 042 N H 06 2HK 6500506...

Page 13: ...5 6 34 1 3 8 5 0 7 5 10 0 7 5 10 0 030 N H 06 2HK06501025B 0 5 LO 7 5 10 0 25 6 34 1 3 8 5 0 7 5 10 0 7 5 10 0 2HK06501525B 0 5 HI 11 3 15 0 38 6 51 2 3 8 5 0 7 5 10 0 11 3 15 0 036 N H 06 2HK06501025...

Page 14: ...25 0 71 7 85 3 4 2 5 0 12 6 15 0 21 0 25 0 F2RP060N93 2HK 6500506B 0 5 LO 4 2 5 0 14 3 17 1 4 2 5 0 4 2 5 0 4 2 5 0 2HK 6500806B LO 6 3 7 5 21 5 25 6 4 2 5 0 6 3 7 5 6 3 7 5 2HK 6501006B LO 8 4 10 0...

Page 15: ...E PHASE HEATERS Model Heater Model Min CFM Max Static Total Heat1 KW Staging KW MBH W1 Only W2 Only W1 W2 Static Tap 220V 240V 220V 240V 220V 240V 220V 240V 220V 240V F2RP024N93 2HK06501025B 0 5 LO 8...

Page 16: ...gh 1575 1535 1475 1390 1310 1418 1382 1328 1251 1179 Med high 1375 1315 1255 1185 1110 1238 1184 1130 1067 999 Med low 1210 1160 1110 1050 980 1089 1044 999 945 882 Low 1035 990 940 890 825 932 891 84...

Page 17: ...64 Med 2125 3613 2020 3434 1910 3247 1805 3069 1705 2899 Low 1655 2814 1605 2729 1550 2635 1500 2550 1450 2465 MODEL Blower Motor Speed 220 Volt 50 HZ CFM or M3 H External Static Pressure IWG or PA 0...

Page 18: ...T PUMP FIELD INSTALLED JUMPER TERMINAL NOT AVAILABLE ON ALL THERMOSTATS FAN COIL UNIT R Y G W2 W1 O C O R Y G T E W O X R B Y W NOTE TO CHANGE HEAT QUANTITY DURING DEFROST REVERSE CONNECTIONS AT W1 W2...

Page 19: ...s to be cleaned or replaced it should be washed with Calgon coilclean mix one part Coilclean to seven parts water Allow solution to remain on coil for 30 minutes before rinsing with clean water Soluti...

Page 20: ...without notice Printed in U S A 035 14520 001 Rev B 0803 Copyright by York International Corp 2003 All rights reserved Supersedes 035 14520 001 Rev A 0902 Unitary 5005 Norman Products York OK Group D...

Reviews: