![York E4TS030 Technical Manual Download Page 22](http://html1.mh-extra.com/html/york/e4ts030/e4ts030_technical-manual_3758844022.webp)
036-21342-002 Rev. E (0505)
22
Unitary Products Group
For notes see Page 11.
Multipliers for determining the performance with other indoor sections.
2-CYLINDER OPERATION
1-CYLINDER OPERATION
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HEATING PERFORMANCE DATA
E4TS060S06A WITH N1VSD2006 / G2FD061S21 - HIGH CFM 2-CYLINDER OPERATION
ID CFM
1540
1860
2075
OD DB
ID DB (°F)
MBTUH
1,2
KW
MBTUH
1,2
KW
MBTUH
1,2
KW
60
60
65.76
4.68
66.22
4.71
66.68
4.74
70
63.45
4.98
64.33
5.02
65.20
5.07
80
61.15
5.27
62.43
5.33
63.72
5.40
47
60
56.89
4.31
57.80
4.39
58.70
4.47
70
54.00
4.51
55.00
4.61
56.00
4.70
80
51.10
4.71
52.20
4.82
53.30
4.93
35
60
46.70
3.92
47.54
4.04
48.37
4.16
70
43.54
4.04
44.43
4.17
45.31
4.30
80
40.38
4.17
41.32
4.30
42.25
4.44
17
60
29.71
3.45
30.61
3.58
31.51
3.70
70
28.44
3.50
29.20
3.68
29.96
3.86
80
27.16
3.55
27.79
3.79
28.41
4.02
7
60
21.86
2.75
22.24
2.81
22.63
2.87
70
20.78
2.86
21.19
2.94
21.60
3.02
80
19.70
2.96
20.14
3.06
20.57
3.16
-3
60
13.59
2.44
13.84
2.50
14.08
2.56
70
12.92
2.53
13.18
2.61
13.44
2.68
80
12.25
2.62
12.53
2.72
12.80
2.81
E4TS060S06A WITH N1VSD2006 / G2FD061S21 - LOW CFM 1-CYLINDER OPERATION
ID CFM
1000
1200
1350
OD DB
ID DB (°F)
MBTUH
1,2
KW
MBTUH
1,2
KW
MBTUH
1,2
KW
60
60
36.04
2.14
36.57
2.14
37.10
2.13
70
33.56
2.28
34.11
2.28
34.65
2.28
80
31.08
2.42
31.64
2.42
32.20
2.42
47
60
26.89
2.03
28.43
2.03
29.97
2.04
70
25.57
2.13
26.60
2.14
27.63
2.15
80
24.26
2.24
24.77
2.25
25.28
2.26
35
60
17.25
1.86
19.73
1.88
22.20
1.89
70
17.10
1.93
18.56
1.95
20.02
1.97
80
16.94
2.00
17.39
2.02
17.84
2.04
Air Handler
Coil
HIGH CFM
LOW CFM
MBTUH KW MBTUH KW
N1VSD20
G1FD060S24
0.98
1.00
0.93
0.98
F(2,3)FV060
0.98
1.00
0.93
0.98
Variable Speed
Furnace
Coil
MBTUH KW MBTUH KW
P1XDD20V112
G2FD060S24
0.98
0.99
0.90
0.94
P1XDD20V112
G2FD061H24
1.00
0.99
0.92
0.95
P1XUD20V112
G1UA060S24
0.98
0.98
0.90
0.93
P1XUD20V112
G1FA060S24
0.98
0.98
0.90
0.93
P1XUD20V112
G2FD060S24
0.98
0.98
0.90
0.93
P1XUD20V112
G2FD061H24
1.00
0.98
0.92
0.93
Air Handler
Coil
LOW CFM
MBTUH
KW
N1VSD20
G1FD060S24
0.89
0.91
F(2,3)FV060
0.88
0.90
Variable Speed
Furnace
Coil
MBTUH
KW
P1XDD20V112
G2FD060S24
0.88
0.95
P1XDD20V112
G2FD061H24
0.88
0.92
P1XUD20V112
G1UA060S24
0.87
0.95
P1XUD20V112
G1FA060S24
0.87
0.95
P1XUD20V112
G2FD060S24
0.87
0.95
P1XUD20V112
G2FD061H24
0.87
0.93