background image

036-21630-001-B-0904

Unitary Products Group

11

FEATURES

All models are available with a wide variety of factory-
mounted options such as electric heaters, phase monitor, 
convenience outlet, dirty filter switch, disconnect switch, 
smoke detectors, and coil guards to make them suitable for 
almost every application.

All units are self-contained and assembled on full perimeter 
base rails with forklift holes on three sides and holes for over-
head rigging. Every unit is completely piped, wired, charged 
and tested at the factory to simplify the field installation and to 
provide years of dependable operation.

All models (including those with an economizer) are suitable 
for either bottom or horizontal duct connections. For bottom 
duct, remove the sheet metal panels from the supply and 
return air openings through the base of the unit. For horizon-
tal duct, remove the supply and return air panels on the rear 
of the unit.

All models are available with these “factory mounted” outdoor 
air damper options:

Single enthalpy economizer

Motorized outdoor air damper

Supply air blowers are equipped with a belt drive that can be 
adjusted to meet the exact requirements of the job.

All compressors are equipped with internal pressure relief. 
Every refrigerant circuit includes a liquid line filter-drier, a high 
pressure switch and a suction line with a freezestat and low 
pressure/loss of charge switch to protect all system compo-
nents.

Simplicity

®

 

Controls - 

Simplicity

®

 control boards have 

standardized a number of features previously available 
only as options or by utilizing additional controls.

Low Ambient 

- An integrated low-ambient control 

allows all units to operate in the cooling mode down 
to 0ºF outdoor ambient without additional assis-
tance. Optionally, the control board can be pro-
grammed to lockout the compressors when the 
outdoor air temperature is low or when free cooling 
is available.

Anti-Short Cycle Protection

 - To aid compressor 

life, an anti-short cycle delay is incorporated into the 
standard controls. Compressor reliability is further 
ensured by programmable minimum run times. For 
testing, the anti short cycle delay can be temporarily 
overridden with the push of a button.

Fan Delays

 - Fan on and fan off delays are fully pro-

grammable and are independent of one another. All 
units are programmed with default values based 
upon their configuration of cooling and heat.

Safety Monitoring

 - The control board monitors the 

high and low-pressure switches, the freezestats, the 
gas valve, if applicable, and the temperature limit 
switch on gas heat units. The unit control board will 
alarm on ignition failures, compressor lockouts and 
repeated limit switch trips.

Nuisance Trip Protection

- To prevent nuisance 

trouble calls, the control board uses a “three strikes, 
you’re out” philosophy. The high and low-pressure 
switches and the freezestats must trip three times 
within two hours before the unit control board will 
lock out the compressor.

On Board Diagnostics

 - Each alarm will energize a 

trouble light on the thermostat, if so equipped, and 
flash an alarm code on the control board LED. Each 
high and low-pressure switch alarm as well as each 
freezestat alarm has its own flash code. The control 
board saves the five most recent alarms in memory, 
and these alarms can be reviewed at any time. 
Alarms and programmed values are retained 
through the loss of power.

All units have long lasting powder paint cabinets with 750 
hour salt spray test approval under ASTM-B117 procedures.

All models are CSA listed.

Warranty

 - All models include a one-year limited parts 

warranty on the complete unit. Compressors and electric 
heater elements carry a five-year warranty

Electric Heat Operation

 - All electric heat models are 

wired for a single power source and include a bank of 
nickel chromium elements mounted at the discharge of 
the supply air blower to provide a high velocity and uni-
form distribution of air across the heating elements. 
Every element is fully protected against excessive tem-
perature by thermal limit switches.

The power supply wiring can be routed into the control 
box through a threaded pipe connection (field supplied) 
in the base pan of the unit or through a knockout in the 
wiring panel on the side of the unit.

BAS Controls

 - York’s Sunline™ series units offer fac-

tory mounted BAS controls such as 

Simplicity

®

 INTELLI-

Comfort™, Novar, Honeywell, Johnson, and CPC.

Summary of Contents for BP 072

Page 1: ...or frame All units include Powder Paint finish that meets ASTM B 117 750 hour salt spray standards Permanently lubricated motors Bottom or side air discharge configuration capability field convertibl...

Page 2: ...B DIMENSIONS 29 Tbl Pg LIST OF TABLES 1 SOUND POWER RATING 15 2 CAPACITY RATINGS 15 3 BP072 COOLING CAPACITIES 6 TON 16 4 BP072 HEATING CAPACITIES 18 5 SUPPLY AIR BLOWER PERFORMANCE 6 TON BELT DRIVE S...

Page 3: ...L Options 1 3 4 M Options 1 2 3 4 N Options 2 3 P Options 2 4 Q Options 2 3 4 R Options 3 4 S Option 5 T Options 1 5 U Options 1 3 5 V Options 1 4 5 W Options 1 3 4 5 X Options 3 5 Y Options 4 5 Z Op...

Page 4: ...se Monitor CQ CPC Controller DFS APS Technicoat Evap Cond Coils Coil Guard CR CPC Controller DFS APS Technicoat Evap Cond Coils Phase Monitor Coil Guard CS CPC Controller DFS APS SS Drain Pan CT CPC C...

Page 5: ...Controller DFS APS SS Drain Pan Phase Monitor Coil Guard HU Honeywell Excel 10 Controller DFS APS SS Drain Pan Technicoat Cond Coils HV Honeywell Excel 10 Controller DFS APS SS Drain Pan Technicoat Ev...

Page 6: ...ty Intelli Comfort Controller LB Simplicity Intelli Comfort Controller Phase Monitor LC Simplicity Intelli Comfort Controller Coil Guard LD Simplicity Intelli Comfort Controller Phase Monitor Coil Gua...

Page 7: ...Pan Dirty Filter Switch Hinged Filter Door Toolless Access Panels BN SS Drain Pan Phase Monitor Coil Guard Dirty Filter Switch Hinged Filter Door Toolless Access Panels BS Bottom Drain Connection Hing...

Page 8: ...FS APS SS Drain Pan Phase Monitor Coil Guard Technicoat Evap and Cond Coils Hinged Filter Door Toolless Access Panels GA Honeywell Excel 10 Controller with Dirty Filter Switch Air Proving Switch Hinge...

Page 9: ...Guard Dirty Filter Switch Hinged Filter Door Toolless Access Panels UH Technicoat Condenser Coil Phase Monitor Coil Guard Dirty Filter Switch Hinged Filter Door Toolless Access Panels UJ Technicoat E...

Page 10: ...LINC Controller Hinged Filter Door Toolless Access Panels XB Intelli Comfort w ModLINC Controller Phase Monitor Hinged Filter Door Toolless Access Panels XC Intelli Comfort w ModLINC Controller Coil G...

Page 11: ...es For testing the anti short cycle delay can be temporarily overridden with the push of a button Fan Delays Fan on and fan off delays are fully pro grammable and are independent of one another All un...

Page 12: ...e complete coil for maximum protection ELECTRIC HEATERS Wired for single point power supply These nickel chromium heater elements are pro vided with limit and automatic reset capability to prevent ope...

Page 13: ...operation of the unit by interrupting power to the control board if smoke is detected within the air compartment STAINLESS STEEL DRAIN PAN An optional rust proof stainless steel drain pan is availabl...

Page 14: ...without power exhaust This accessory includes a rain hood a bird screen and a fully assembled damper With bottom duct connections the damper should be mounted over the opening in the return air panel...

Page 15: ...MBH ARI RATINGS1 HEATING CAPACITY 47 F 17 F COOLING PERFORMANCE SOUND RATING2 bels NOTES 1 Certified in accordance with the Unitary Large Equipment certification program which is based on ARI Standar...

Page 16: ...OOR AMBIENT TEMPERATURE 105 F 115 F GROSS CAP 1 MBH INPUT2 POWER kW GROSS SENSIBLE CAPACITY1 MBH GROSS CAP 1 MBH INPUT2 POWER kW GROSS SENSIBLE CAPACITY1 MBH RETURN AIR DRY BULB TEMP F RETURN AIR DRY...

Page 17: ...47 9 40 9 33 9 26 9 19 9 67 57 2 7 76 57 2 53 8 46 8 39 8 32 8 25 8 18 8 62 53 8 7 75 53 8 53 8 53 8 47 0 40 0 33 1 26 1 57 52 7 7 70 52 7 52 7 52 5 45 5 38 5 31 5 24 5 2700 72 63 8 7 94 50 4 42 4 34...

Page 18: ...R MOTOR HEAT MBH 3 415 X KW TABLE 5 SUPPLY AIR BLOWER PERFORMANCE 6 TON BELT DRIVE SIDE DUCT APPLICATION RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 3200 1150 2325 1182 2425...

Page 19: ...0 0 12 0 14 0 16 0 19 0 22 20 30KW 0 06 0 07 0 08 0 09 0 11 0 13 0 15 0 17 0 20 0 23 0 26 0 06 0 07 0 08 0 09 0 10 0 11 0 12 0 14 0 16 0 19 0 22 0 08 0 10 0 12 0 14 0 16 0 18 0 20 0 23 0 26 0 29 0 32...

Page 20: ...462 13 6 16 4 34 7 35 2CE045120462 19 5 23 5 43 6 45 2CE045130462 28 8 34 6 57 6 60 NONE 0 0 11 9 15 2CE04511058 10 6 10 2 24 7 25 2CE04511558 15 9 15 3 31 0 35 2CE04512058 21 2 20 4 37 4 40 2CE045130...

Page 21: ...62 13 6 16 4 39 7 40 2CE045120462 19 5 23 5 48 6 50 2CE045130462 28 8 34 6 62 6 70 NONE 0 0 15 9 20 2CE04511058 10 6 10 2 28 7 30 2CE04511558 15 9 15 3 35 0 40 2CE04512058 21 2 20 4 41 4 45 2CE0451305...

Page 22: ...ins Per Inch 18 Face Area Sq Ft 17 1 COMPRESSOR Qty Per Unit Scroll Type 1 AIR FILTERS Quantity Per Unit 15 X 20 X 1 or 2 2 Quantity Per Unit 14 X 25 X 1 or 2 1 Total Face Area sq ft 6 6 CHARGE Refrig...

Page 23: ...TRANSFORMER TO REMOTE SENSOR 2TH040702224 IF USED NOT USED ADD JUMPER ADD JUMPER 4 4 3 2 1 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 INCLUDES SUBBASE 2 SECOND STAGE COOLING IS NOT REQUIRED ON UN...

Page 24: ...036 21630 001 B 0904 24 Unitary Products Group FIGURE 3 UNIT DIMENSIONS FRONT VIEW FIGURE 4 UNIT WITH ECONOMIZER RAINHOOD DETAIL A...

Page 25: ...036 21630 001 B 0904 Unitary Products Group 25 FIGURE 5 UNIT WITH FIXED OUTDOOR AIR MOTORIZED DAMPER RAINHOOD DETAIL B FIGURE 6 UNIT DIMENSIONS REAR VIEW...

Page 26: ...Wiring Side Bottom C 1 5 8 KO Gas Piping Front D 1 1 2 KO Gas Piping Bottom 1 Opening in the bottom to the unit can be located by the side in the insulation 2 Do not remove the 2 knockout ring TABLE 1...

Page 27: ...036 21630 001 B 0904 Unitary Products Group 27 FIGURE 8 TYPICAL APPLICATIONS...

Page 28: ...GRAVITY BACK OF UNIT TABLE 16 BP 4 POINT LOADS WEIGHT DISTRIBUTION UNIT TOTAL A B C D BP072 612 136 133 170 173 TABLE 17 BP 6 POINT LOADS WEIGHT DISTRIBUTION UNIT TOTAL A B C D E F BP072 612 91 90 89...

Page 29: ...ure switch and a suction line with a freezestat and low pressure loss of charge switch The unit control circuit includes a 75 VA transformer a 24 volt circuit breaker and a relay board with a compress...

Page 30: ...l spring isolation and sound muf fling to minimize vibration and noise and be exter nally isolated on a dedicated independent mounting Coils a Evaporator and condenser coils shall have alumi num plate...

Page 31: ...nd return air damper assembly to prevent the supply air temperature from dropping below 55 F Changeover from compressor to economizer oper ation shall be provided by an integral electronic enthalpy co...

Page 32: ...tary 5005 Norman Products York OK Group Drive 73069 BAS CONTROLS Simplicity INTELLI Comfort CPC JOHNSON HONEYWELL NOVAR BAS READY ECONOMIZER BELIMO ACTUATOR WITHOUT A CONTROLLER HINGED FILTER DOOR ACC...