York AVY24 THRU 60 Technical Manual Download Page 3

Johnson Controls Unitary Products

3

256819-YTG-J-1208

COIL TECHNICAL DATA

Models

Application

Refrig. 

Conn. Types

Face Area

(Sq. Ft.)

Rows

Deep

Fin 

Per In.

Coil Size

Tube

Geometry

Tube

Dia.

Fin

Type

TXV

AVY24B3XH21

Cooling / 

Heat Pump

Sweat

3.89

2

14

(2) 16 x 17.5

1 x 0.866

3/8

Enhanced

None

AVY24B2AH21

2A

AVY24B4EH21

4E

AVY24B4FH21

4F

AVY24B4KH21

4K

AVY36C3XH21

Cooling / 

Heat Pump

Sweat

4.86

3

12

(2) 20 x 17.5

1 x 0.866

3/8

Enhanced

None

AVY36C2AH21

2A

AVY36C4EH21

4E

AVY36C4FH21

4F

AVY36C4GH21

4G

AVY36C4HH21

4H

AVY36C4KH21

4K

AVY36C4MH21

4M

AVY48D3XH21

Cooling / 

Heat Pump

Sweat

5.83

3

11

(2) 24 x 17.5

1 x 0.866

3/8

Enhanced

None

AVY48D2CH21

2C

AVY48D4FH21

4F

AVY48D4HH21

4H

AVY48D4JH21

4J

AVY48D4KH21

4K

SVY48D3XN21

None

SVY48D2CN21

2C

AVY60D3XH21

Cooling / 

Heat Pump

Sweat

5.83

3

11

(2) 24 x 17.5

1 x 0.866

3/8

Enhanced

None

AVY60D2CH2

2C

AVY60D4HH21

4H

AVY60D4JH21

4J

AVY60D4KH21

4K

SVY60D3XN21

None

SVY60D2CN21

2C

Note:

 H models are available with a factory installed horizontal drain pan.

COOLING CAPACITY

Models

Rated CFM

Entering Air °F 

(Dry / Wet Bulb)

MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG

35 / 61.5

40 / 68.5

45 / 76.0

50 / 84.0

FULL-CASED “A” TYPE MULTI-POSITION

AVY24B**H21

800

85/72

35.0

31.8

28.4

24.7

80/67

32.2

29.1

25.7

22.3

75/62

26.4

23.4

21.0

17.1

70/57

21.4

18.6

20.2

12.1

AVY36C**H21

1200

85/72

51.3

46.7

41.7

36.8

80/67

41.1

36.3

31.8

27.1

75/62

32.1

27.0

29.4

21.9

70/57

27.6

25.4

23.5

18.3

AVY48D**H21

SVY48D**N21

1600

85/72

100.5

86.4

72.0

56.8

80/67

80.4

67.5

55.0

42.1

75/62

62.7

49.9

40.7

34.0

70/57

53.9

47.2

36.81

28.71

AVY60D**H21

SVY60D**N21

1850

85/72

119.9

101.0

82.0

62.2

80/67

96.0

79.2

62.6

45.8

75/62

74.8

58.6

46.2

37.0

70/57

64.3

55.4

43.2

33.7

Summary of Contents for AVY24 THRU 60

Page 1: ...ovides easy installation to convert the air handler to the required refrigerant which is a true bolt on design that does not require brazing to replace or install MicroBlueTM Coated Fins All air handl...

Page 2: ...6 17 5 21 5 w o cladding 22 5 with cladding 12 3 8 13 29 32 14 19 32 7 8 1 2 1 3 8 1 1 23 32 1 1 4 7 8 1 2 3 8 3 4 AVY36C H21 52 21 17 1 8 17 13 32 18 3 32 7 8 AVY48D H21 57 24 5 22 1 8 20 29 32 21 19...

Page 3: ...1 Cooling Heat Pump Sweat 5 83 3 11 2 24 x 17 5 1 x 0 866 3 8 Enhanced None AVY60D2CH2 2C AVY60D4HH21 4H AVY60D4JH21 4J AVY60D4KH21 4K SVY60D3XN21 None SVY60D2CN21 2C Note H models are available with...

Page 4: ...0 840 1387 823 D N A 1 Airflow at nominal voltage bottom return at 0 5 external static pressure tested without filter installed dry coil conditions 2 These units have variable speed motors that automa...

Page 5: ...PERMANENT Size 16 x 20 x1 20 x 20 x1 22 x 20 x1 22 x 20 x1 Permanent Type Kit 1PF0601BK 1PF0602BK 1PF0603BK 1PF0603BK Shipping Operating Weight lbs 140 134 170 164 AV 196 185 SV 194 181 AV 199 188 SV...

Page 6: ...3 6 4 8 12 3 16 4 3 6 4 8 3 6 4 8 3 6 4 8 4HK 6500806 0 5 Heat C 5 6 7 5 19 2 25 6 2 8 3 75 5 6 7 5 5 6 7 5 4HK 6501006 0 5 Heat C 7 2 9 6 24 6 32 8 3 6 4 8 7 2 9 6 7 2 9 6 4HK16501506 0 5 Heat C 10 8...

Page 7: ...0 0 53 08 58 75 60 60 6 6 4HK16501506 60 0 74 75 83 75 90 90 3 3 4HK16501806 73 3 89 19 100 38 90 110 3 2 4HK16502006 80 0 96 42 108 75 100 125 3 1 4HK16502506 100 0 118 08 133 75 125 150 1 1 0 1 O C...

Page 8: ...rsion table on Page 5 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY COPPER WIRE 208 230 3 60 Models Heat Kit Three Phase Heater Amps 240V Field Wiring Min Circuit Ampacity Max O C P 1 Amps Type 75 C...

Page 9: ...national and local safety codes Voltage limits are as follows Airflow must be within the minimum and maximum limits approved for electric heat evaporator coils and outdoor units COOLING MODELS WITH EL...

Page 10: ...SEER enhancement 2 Remove humidistat jumper on air handler control board 3 For heat pump applications set MODE jumper on air handler control board to the HP position 4 To change quantity of heat duri...