2.  Summarize of CCM

2-1 Basic Requirements

  (1) Applicable Power Voltage Range: Input Voltage 220

~

240VAC±10%.

  (2)AC Input Power Frequency: 50Hz/60Hz.

 (3)Working  

Ambient  Temp.:  -10

ºC

~

+43

ºC

.

  (4)Working Ambient Humidity: RH40%~RH90%.

(5)CCM with Model YDSA-CCM01 is applicable to all models of YORK Air-conditioners.

2-2 Components of Central Control Monitor System

The Central Control Monitor System consists of CCM, (NIM), Electric Control, PC and

Communication Wire. Some NIM is inside the indoor PCB and needn’t set separately. (Please

refer to the technical information of indoor units.)

The CCM can connect up to max 64 indoor units, which together compose one LAN

(Local Area Network), thus the CCM can central control to all air-conditioners in the LAN,

including sending every kind of control order to every air-conditioner and setting running

states of every air-conditioner. And the control

signal of CCM can arrive to the farthest 500

meters, which can meet various control

requirements for customers.

Through interfacing with PC or Gateway,

the CCM can realize central management

control, parameters setting and states query

to all air-conditioners in the LAN by PC.

What’s more, connecting with WAN (Wide

Area Network) by PC or Gateway can realize

long-distance control. And every PC or

Gateway can connect max. 16 CCM.

Installation Sketch Map of Network Air-condition Building

NIM

Max 64

Max 16

A/C

CCM

PC

Internet

CCM

CCM

PC

Summary of Contents for AMR03M

Page 1: ...CONDITIONING CENTRAL CONTROL MONITOR AMR03M Please read this installation manual carefully before installing your air conditioner Please keep this manual in a safe place for future reference This manu...

Page 2: ...or units which together compose one LAN Local Area Network thus the CCM can central control to all air conditioners in the LAN including sending every kind of control order to every air conditioner an...

Page 3: ...mal communication with NIM then Blank will be displayed in dynamic circulation Otherwise no any display f Lock Symbol means the CCM is in Lock state or the buttons are in Lock state ON means the butto...

Page 4: ...n warning data of the air conditioner or the CCM The display range of ERROR code is E0 EF where E means ERROR 0 F means ERROR code or Network ERROR display 00 0F If no EEROR then display E and will be...

Page 5: ...data of the first page will be displayed b The data of other pages can be displayed in circulation by pressing buttons or c The running state data of different air conditioners can be queried by press...

Page 6: ...e air conditioner in network has malfunction or the CCM network itself has malfunction the indicator lamp will flash in 2Hz If one or more online air conditioners in network are in running state inclu...

Page 7: ...ffect operation by remote controller If both are closed at the same time Urgent Stop switch takes priority 5 3 ON OFF Operation At any time all online air conditioners in CCM network will be carried o...

Page 8: ...DE button to enter into MODE set and select circularly between COOLING HEATING and FAN ONLY Pressing OK button to confirm all settings and send to the corresponding air conditioners Press MODE button...

Page 9: ...OFF MODE SET state In communication with PC NO 60 indoor unit in network is in Heating mode Set Temp 28 C Middle Fan Speed 4 5 hours Timer On 12 hours Timer Off ON and ERROR In communication with PC...

Page 10: ...all online air conditioners will be off If all present online air conditioners are in OFF state then it will send ON order as follows if pressing at Mode Setting Page then it will carry out ON operat...

Page 11: ...dule Protection PB Reserve EA Compressor Over current 4 times PA Reserve E9 Communication malfunction between PCB and Display board P9 Reserve E8 Fan motor checking out of control P8 Compressor Over c...

Page 12: ...e or returned to the manufacturer for disposal Under No circumstances should refrigerant be vented to atmosphere Where appropriate drain the refrigerant oil from each system into a suitable container...

Reviews: