background image

TECHNICAL GUIDE

SINGLE PIECE STANDARD ECM
AIR HANDLERS

FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS

MODELS: AHE18 THRU 60* 

Due to continuous product improvement, 
specifications are subject to change without notice.

Visit us on the web at:

www.upgnet.com and www.york.com

Additional rating information can be found at:

www.ahridirectory.org

WARRANTY

Standard 5-year limited parts warranty.

Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.

ISO 9001

Certified Quality

Management System

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

697887-YTG-H-0514

DESCRIPTION

The AHE Air Handler line offers the ultimate in comfort, sound
and application flexibility. 

This unit may be used for upflow, down-

flow, horizontal right, or horizontal left applications.

 No special kits are

required to install this deluxe product.

All JCI Unitary Products air handlers and coils use a TXV to pro-
vide our customers with the optimum performance and refriger-
ant control. Air handlers are shipped with “Flex-coils” without a
factory installed metering device. For added flexibility, an R-22
or R-410A TXV or orifice can be field installed to meet your
refrigerant choice.

FEATURE

Thermal Expansion Valve

 - Provides the ultimate refrigerant

control required for today’s high efficient product. The UPG bolt-
on TXV provides easy installation to convert the air handler to
the required refrigerant, which is a true bolt-on design that does
not require brazing to replace or install.

Insulated Cabinet

 - All air handler cabinets are thermally insu-

lated with 3/4” foil faced insulation to prevent sweating.

Factory Sealed -

 Achieves 2% or less total airflow leakage rate

at duct blaster field test conditions for system airflow verifica-
tion.

Durable Finish Inside and Out

 - Air handler casings are made

of pre-painted galvanized steel which provides a better paint to
steel bond that resists corrosion and rust creep. All internal coil
sheet metal parts are made of G60 galvanized or prepainted
G30 galvanized.

Filters - 

All models have internal filter racks provided for use

with 1” thick standard size filters.

Electric Heat Kits - 

6HK series of field installed electric heat

kits are available for installation friendly and easy service appli-
cations. 

High Efficiency Blowers - 

All models use high efficiency

brushless DC motors to provide cooling SEER rating enhance-
ment.

Summary of Contents for AHE22B

Page 1: ...ry installed metering device For added flexibility an R 22 or R 410A TXV or orifice can be field installed to meet your refrigerant choice FEATURE Thermal Expansion Valve Provides the ultimate refrige...

Page 2: ...20 29 32 23 1 2 7 8 1 All dimensions are in inches 2 Actual size conduit size COIL TECHNICAL DATA Models Application Refrig Conn Types Face Area Sq Ft Rows Deep Fins Per In Coil Size Tube Geometry Tub...

Page 3: ...8 12 8 70 57 21 2 18 6 16 2 13 7 795 85 72 50 8 45 2 38 4 32 0 80 67 43 7 36 8 31 24 0 75 62 35 7 29 5 23 1 16 1 70 57 27 9 24 5 21 17 6 985 85 72 64 9 54 45 6 37 8 80 67 52 3 44 6 36 9 28 4 75 62 42...

Page 4: ...51 3 41 5 80 67 56 5 48 2 39 7 29 9 75 62 45 1 36 8 28 3 18 9 70 57 34 4 31 26 8 22 5 1195 85 72 79 5 69 7 59 9 48 6 80 67 65 2 55 5 45 5 34 9 75 62 52 2 42 5 32 6 21 8 70 57 40 1 36 1 31 1 26 2 1385...

Page 5: ...FACTOR 220V 240V 0 84 ELECTRICAL DATA COOLING ONLY Models Motor FLA1 Minimum Circuit Ampacity MOP2 Minimum Wire Size AWG 3 AHE18B AHE22B AHE24B AHE30B 2 8 3 5 15 14 AHE34C AHE36C AHE42D 4 1 5 1 15 14...

Page 6: ...nversion table on Page 5 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY 208 230 1 60 Air Handler Models Heater Models1 2 Heater Amps 240V Field Wiring Min Circuit Ampacity MOP 3 Min Wire Size AWG 4 20...

Page 7: ...ty MOP1 Min Wire Size AWG 2 208V 230V 208V 230V 208V 230V Circuit Circuit Circuit 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd 1st3 2nd 3rd AHE22B AHE24B AHE30B 6HK16501306 52 0 22...

Page 8: ...0253 46 2 57 6 65 3 60 70 6 4 6HK165025253 57 7 70 0 79 6 70 80 4 4 1 MOP Maximum Overcurrent Protection device must be HACR type circuit breaker or time delay fuse 2 Stated sizes are for 75 C copper...

Page 9: ...365 287 NA AHE36C High 5 1465 1415 1360 1307 1246 1183 1118 Med High 4 1260 1204 1142 1075 1008 946 876 Med 3 1088 1022 939 862 782 721 626 Med Low 2 998 810 717 630 562 493 444 Low 1 903 707 411 323...

Page 10: ...10 Johnson Controls Unitary Products 697887 YTG H 0514 TYPICAL THERMOSTAT CONNECTION...

Page 11: ...ICAL THERMOSTAT WIRING FOR 2 STAGE HEAT PUMP WITH ECM BLOWER MOTOR A001 001 NOTICE WIRING FOR BLOWER MOTOR MAY REQUIRE FIELD ADJUSTMENT DEPENDING ON MATCHUP OF SYSTEM UNITS REFER TO THE AIR FLOW DATA...

Page 12: ...change without notice Published in U S A 697887 YTG H 0514 Copyright 2014 by Johnson Controls Inc All rights reserved Supersedes 697887 YTG G 0314 York International Corp 5005 York Drive Norman OK 73...

Reviews: