background image

036-21610-002 Rev. A (1104)

6

Unitary Products Group

ACCESSORIES

PROPANE
CONVERSION KIT -- 1NP0347 (32, 64 & 80 MBH)

1NP0348 (48, 92,& 104 MBH)

This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation at altitudes up to 2,000
ft. Conversion should be made by qualified distributor or
dealer personnel.

COMBUSTIBLE FLOOR BASE

1CB0314 = 

For 14-1/4" cabinet models

1CB0317 

= For 17-1/2" cabinet models

1CB0321 

= For 21" cabinet models

1CB0324 

= For 24-1/2" cabinet models

HIGH ALTITUDE PRESSURE SWITCH

These accessory kits may be used to convert units for high
altitude operation. Conversion must be made by qualified dis-
tributor or dealer personnel.

HIGH PRESSURE SWITCH

Input 

(MBH)

Output 

(MBH)

2,000  to 
5,500 Ft.

>5,500  to 
10,000 Ft.

40

32

1PS0301

1PS0301

57

48

1PS0301

1PS0301

80

64

1PS0302

1PS0302

100

80

1PS0312

1PS0311

115

92

1PS0312

1PS0311

130

104

1PS0312

1PS0311

FIELD INSTALLED ACCESSORIES - ELECTRICAL

 

MODEL NO.

DESCRIPTION

USED WITH

2TB17700424

SUBBASE (24V) -One-stage Heat / Cool.  Manual changeover.      

System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2TH13700424

THERMOSTAT-One-stage Heat.  Deluxe 24V with heat only subbase, 

does not include fan switch. NOTE: For one-stage cool or one-stage 

heat/cool, must be used with subbase 2TB17700424.

ALL MODELS

2ET03700324

THERMOSTAT- Hardwired, 1 Heat / 1 Cool. Manual changeover, Sys-

tem Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2ET03701224

THERMOSTAT-Power Stealing, 1 Heat / 1 Cool.  Manual changeover,    

System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2ET03700124

THERMOSTAT-Hardwired, 1 Heat / 1Cool. Programmable, Auto 

changeover. System Switch: Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

2ET03701024

THERMOSTAT-Power Stealing, 1 Heat / 1 Cool. Programmable, Auto 

changeover. System Switch:Cool-Off-Heat. Fan Switch: Auto-On.

ALL MODELS

6TT03701124

TALKING THERMOSTAT 1Heat/1Cool

ALL MODELS

Summary of Contents for AFFINITY PS8

Page 1: ...its are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code ANSI Z223 1 latest edition WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger warranty on commercial applica tions 5 year limited parts warranty FEATURES Dedicated downflow models may be easily applied with out any field conversion Top vent connection a...

Page 2: ...16N080DN11 17 1 2 B 17 1 2 16 1 4 13 1 8 4 0 11 5 8 3 3 4 PS8B12N100DN11 17 1 2 B 17 1 2 16 1 4 13 1 8 4 0 11 5 8 3 3 4 PS8C20N100DN11 21 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4 PS8C16N115DN11 21 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4 PS8C20N115DN11 21 C 21 19 3 4 16 5 8 4 0 13 3 8 3 3 4 PS8D20N130DN11 24 1 2 D 24 1 2 23 1 4 20 1 8 4 0 15 1 8 3 3 4 HORIZONTAL SIDEWALL VENTING CLEARANCES MUST USE FIELDS C...

Page 3: ...0 0 25 55 PS8C16N115DN11 115 92 1600 80 0 35 65 PS8C20N115DN11 115 92 2000 80 0 30 60 PS8D20N130DN11 130 104 2000 80 0 40 70 Models Max Outlet Air Temp F Blower Blower Size In Total Unit Amps Max Over current protect Min Wire Size awg 75 ft one way Operation WGT LBS Hp Amps PS8A12N040DN11 150 1 3 6 2 10 x 8 9 0 15 14 100 PS8A12N060DN11 155 1 3 6 2 10 x 8 9 0 15 14 110 PS8A12N080DN11 165 1 3 6 2 10...

Page 4: ...50 940 810 700 Medium High 1400 1360 1290 1220 1150 1060 970 860 730 590 Medium Low 1230 1210 1170 1120 1060 990 910 810 680 560 Low 980 970 960 930 890 830 760 680 550 450 PS8B16N080DN11 High 2070 2000 1930 1850 1770 1670 1580 1470 1360 1250 Medium 1650 1630 1610 1560 1490 1420 1360 1270 1170 1040 Low 1410 1400 1370 1340 1320 1270 1210 1140 1050 950 PS8B12N100DN11 High 1710 1650 1580 1510 1420 13...

Page 5: ...total system static is 0 58 w c To determine the system airflow complete the following steps 1 Obtain the airflow values at 0 50 0 60 ESP Airflow 0 50 2110 CFM Airflow 0 60 2020 CFM 2 Subtract the airflow 0 60 from the airflow 0 5 to obtain airflow difference 2020 2110 90 CFM 3 Subtract the total system static from 0 50 and divide this difference by the difference in ESP values in the table 0 60 0...

Page 6: ...1PS0311 115 92 1PS0312 1PS0311 130 104 1PS0312 1PS0311 FIELD INSTALLED ACCESSORIES ELECTRICAL MODEL NO DESCRIPTION USED WITH 2TB17700424 SUBBASE 24V One stage Heat Cool Manual changeover System Switch Cool Off Heat Fan Switch Auto On ALL MODELS 2TH13700424 THERMOSTAT One stage Heat Deluxe 24V with heat only subbase does not include fan switch NOTE For one stage cool or one stage heat cool must be ...

Page 7: ...036 21610 002 Rev A 1104 Unitary Products Group 7 NOTES ...

Page 8: ...e without notice Printed in U S A 036 21610 002 Rev A 1104 Copyright by York International Corp 2004 All rights reserved Supersedes 036 21610 001 Rev A 0804 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...