Unitary Products Group

piece design adds greater water integrity. Rounded 
corners with water drip edges add to the attractive 
appearance. The cabinet panels have a non-fibrous 
insulation that will not release insulation fibers into 
conditioned area.

Top Discharge

 - The top discharge condenser fan does 

not disrupt neighboring areas or dry-out vegetation 
surrounding the unit. The warm air from the top mounted fan 
is blown up away from the structure and any landscaping. 
This allows compact location on multi-unit applications.

Condenser Coil Grille

 - A multi-piece totally enclosed, 

rigidly mounted condenser coil grille provides protection 
from objects after installation and provides protection 
during transit.

Low Operating Sound Level

 - The upward air flow 

carries the normal operating noise up and away from the 
living area. The rigid top panel effectively isolates any 
motor sound. Isolator mounted compressor and the 
rippled fins of the condenser coil muffle the normal fan 
motor and compressor operating sounds. The unique 
formed base pan also aids in sound alterations with it's 
Super-Structure design. This design strategically places 
embossments in the pan for optimum strength and rigidity.

Fan System

 - All models operate over a wide range of 

design conditions with an electrically commutated fan 
motor. These units easily match all types of applications 
and provide greater on site flexibility to match comfort 
requirement. The cooling speed is factory set and can be 
field adjusted to a second speed. The heating speed is 
factory set to maintain mid point rise at the units heating 
input, but can be field adjusted. This allows maximum 
comfort conditions.

Simple Control Circuit

 - A low voltage printed circuit 

board contains a diagnostic indicator light and a low 
voltage terminal strip. An additional set of pin connectors 
is also provided to simplify the field interface of external 
controls. Mate-n-lock plug connectors are used. The 
electrical control box is not located in the compressor 
compartment. The controls are mounted on a Control-Tilt 
control panel to allow the access cover to be removed for 
trouble shooting and maintenance without affecting the 
normal system operating pressures. All wiring internal to 
the unit is color/number coded.

Protected Compressor

 - The compressor is internally 

protected against high pressure and temperature. This is 
accomplished by the simultaneous operation of high 
pressure relief valve and a temperature sensor which protect 
the compressor if undesirable operating conditions occur.

Pressure Switches 

- High pressure and low pressure/

loss of charge switches standard in all units. When 
abnormal conditions are sensed through the pressure 
switches, the unit will lock out preventing any further 
operation until reset or problem is corrected. 

Exclusive Coil Design

 - Grooved copper tubes and 

enhanced aluminum fin construction improves heat 
transfer for maximum efficiency and durability.

Heat Exchangers

 - Are corrosion-resistant, aluminized-

steel tubular construction to provide long-life, trouble-free 
operation. The unique blow-through design also assures 
that condensate does not collect in humid areas when in 
the cooling cycle. This adds to longer heat exchanger life 
and higher long term efficiencies.

Post Purge Induced Draft Combustion

 - Exhausts 

combustion products from the heat exchanger upon 
completion of the heating cycle to prolong the heat 
exchanger life.

Self Diagnostic Fan Control Module

 - Due to this self 

diagnostic control, less on site time is required to trouble 
shoot these units.

Spark To Pilot Ignition

 - Provides faster heat delivery. 

This ignition is highly reliable, durable and eliminates 
nuisance lockouts.

Multi Port In-shot Burners

 - No field adjustment is 

required to mix the air and gas. These burners are 
constructed of high-grade corrosion-resistant, aluminized-
steel.

Low Maintenance

 - Long life, permanently lubricated 

condenser and evaporator fan motor bearings need no 
annual maintenance adding greater reliability to the unit. 
Blower assembly can be easily cleaned by the unique 
Slip- Track slide-out blower assembly.

Secured Service Access Ports

 - Protected, externally 

mounted, re-usable service access ports are provided on 
both the high and low lines for ease of evacuating and 
charging the system. No final field mounting required.

Easy Service Access

 - A large, single panel covers the 

electrical and gas controls makes servicing easy. The 
blower compartment has an additional large panel with a 
built-in handle tab. Removing this panel will allow the 
blower assembly to slide-out for easy removal for 
maintenance and ease of trouble shooting.

Replacement Parts

 - The installer requires no special 

training to replace any of the components of these units 
and does not need to maintain an inventory of unique parts.

System Integration

 - Each unit has the internal ability to 

integrate an electronic air cleaner or humidifier to work in 
conjunction with the base unit.

Field Installed Accessories

Low NOx Kit

 - Kit includes all the necessary hardware 

and instructions to field convert units to reduce emissions 
to less than 40 nanogram per Joule. California 
requirement on single phase models only.

Propane Conversion Kit

 - Kit includes burner orifices, 

gas valve conversion and installation instructions 
necessary to field convert unit from natural gas to propane.

High Altitude Conversion Kit

 (Natural Gas/Propane) - Kit 

includes all necessary labels and instructions to field alter 
units with natural gas/propane for installations above 2000 
feet. Burner orifices must be obtained from Source 1 Parts. 
Propane Conversion Kit must be obtained separately.

Summary of Contents for AFFINITY DNX Series

Page 1: ...nstallation Only utility and duct connections are required at the point of installation The single or two stage gas fired heaters have aluminized steel tubular heat exchangers and spark to pilot ignit...

Page 2: ...ube Aluminum Fin Evaporator Coil Highly Efficient Enhanced Copper Tube Aluminum Fin Condenser Coil Decorative Protective Coil Guard High Efficiency Compressor Rigidly Mounted Pilot Assembly High Grade...

Page 3: ...design allows maximum field flexibility and minimum inventory Condensate Pan A non corrosive long lasting water tight pan is positioned below the evaporator coil to collect and drain all condensate L...

Page 4: ...the unit will lock out preventing any further operation until reset or problem is corrected Exclusive Coil Design Grooved copper tubes and enhanced aluminum fin construction improves heat transfer fo...

Page 5: ...ronic and electro mechanical thermostats All units can operate with single stage heat single stage cool thermostats with or without the economizer Low Ambient Kit Kit provides necessary hardware to co...

Page 6: ...emperature protection The hermetic motor shall be suction gas cooled and have a voltage range of 10 of the unit nameplate voltage b Shall have internal isolation and sound muffling to minimize vibrati...

Page 7: ...8 49 1 8 Width 47 1 4 47 1 4 47 1 4 47 1 4 47 1 4 47 1 4 Height 33 1 2 33 1 2 33 1 2 41 1 2 41 1 2 41 1 2 OPERATING WT lbs 360 395 395 470 470 540 COMPRESSORS Type Scroll 1 spd Scroll 1 spd Scroll 1...

Page 8: ...4 Height 33 1 2 33 1 2 33 1 2 41 1 2 41 1 2 41 1 2 OPERATING WT lbs 360 395 395 470 470 540 COMPRESSORS Type Scroll 1 spd Scroll 1 spd Scroll 1 spd Scroll 1 spd Scroll 1 spd Scroll 1 spd Quantity 1 1...

Page 9: ...60 187 252 125 208 230 3 60 187 252 125 460 3 60 432 504 125 DNY DNX 208 230 1 60 187 252 115 208 230 3 60 187 252 115 460 3 60 432 504 115 042 3 5 DNZ 208 230 1 60 187 252 125 208 230 3 60 187 252 1...

Page 10: ...9 1 8 23 6 19 4 15 2 11 0 26 5 2 0 22 9 18 7 14 5 10 3 67 26 0 1 8 26 0 23 2 19 0 14 8 10 6 24 7 1 9 24 7 22 7 18 5 14 3 10 1 62 23 9 1 8 23 9 23 9 23 9 19 7 15 5 11 3 22 7 1 9 22 7 22 7 22 7 18 5 14...

Page 11: ...6 6 16 6 13 1 9 6 6 1 14 4 2 7 14 4 14 4 14 4 11 4 7 7 4 1 57 17 4 2 5 17 4 17 4 17 4 13 9 10 4 6 9 16 0 2 7 16 0 16 0 15 9 12 4 8 8 5 2 900 72 21 4 2 6 19 5 15 7 11 9 8 0 19 8 2 9 18 9 15 1 11 2 7 4...

Page 12: ...2 5 28 2 23 4 18 6 13 8 67 34 1 2 2 34 1 30 3 25 4 20 5 15 6 32 3 2 5 32 3 29 8 25 0 20 2 15 4 62 31 8 2 2 31 8 31 8 31 8 26 9 22 1 17 2 29 8 2 5 29 8 29 8 29 8 25 0 20 2 15 4 57 31 8 2 2 31 8 31 8 3...

Page 13: ...23 2 23 2 23 2 19 4 15 6 11 8 21 2 3 6 21 2 21 2 21 2 17 7 13 8 10 0 57 23 6 3 2 23 6 23 6 23 6 19 8 16 0 12 2 21 6 3 6 21 6 21 6 21 6 18 0 14 0 10 2 1125 72 27 5 3 4 24 6 20 2 15 8 11 5 25 2 3 7 24 0...

Page 14: ...3 2 34 0 28 3 22 5 16 8 67 40 6 2 8 40 6 37 6 31 7 25 9 20 0 38 4 3 2 38 4 36 0 30 2 24 5 18 7 62 36 9 2 8 36 9 36 9 36 9 31 1 25 2 19 3 35 2 3 2 35 2 35 2 35 2 29 4 23 7 17 9 57 38 0 2 7 38 0 38 0 38...

Page 15: ...3 9 28 4 28 4 28 1 23 6 19 0 14 5 26 2 4 2 26 2 26 2 26 2 21 9 17 2 12 6 57 28 8 3 9 28 8 28 8 28 8 24 2 19 7 15 1 26 6 4 2 26 6 26 6 26 6 22 3 17 5 12 9 1350 72 34 5 4 0 30 4 25 1 19 9 14 6 32 4 4 3...

Page 16: ...3 5 39 5 32 8 26 1 19 4 67 46 5 3 2 46 5 43 7 36 3 29 4 22 6 44 4 3 5 44 4 43 0 36 3 29 6 22 9 62 43 4 3 2 43 4 43 4 43 4 36 5 29 7 22 8 41 3 3 5 41 3 41 3 41 3 34 6 27 9 21 2 57 42 7 3 1 42 7 42 7 42...

Page 17: ...4 1 33 1 33 1 33 0 28 5 23 9 19 4 30 4 4 4 30 4 30 4 30 3 25 9 21 2 16 6 57 33 4 4 2 33 4 33 4 33 3 28 8 24 2 19 7 30 7 4 6 30 7 30 7 30 7 26 4 21 5 17 0 1475 72 39 0 4 4 33 9 28 2 22 5 16 7 36 0 4 8...

Page 18: ...4 2 45 6 38 0 30 3 22 7 67 55 2 3 8 55 2 49 4 41 9 34 3 26 8 51 6 4 1 51 6 48 0 40 4 32 8 25 1 62 50 7 3 7 50 7 50 7 50 7 43 2 35 7 28 2 46 9 4 2 46 9 46 9 46 9 39 3 31 6 24 0 57 49 1 3 5 49 1 49 1 49...

Page 19: ...5 0 38 0 38 0 37 6 30 9 24 1 17 4 35 8 5 4 35 8 35 8 35 6 28 9 22 0 15 2 57 39 0 4 9 39 0 39 0 37 1 30 3 23 6 16 8 37 1 5 1 37 1 37 1 35 4 28 7 21 8 15 0 1750 72 43 8 5 2 40 6 33 2 25 9 18 5 39 7 5 7...

Page 20: ...5 1 53 6 45 2 36 8 28 3 67 67 7 4 6 67 7 59 3 51 0 42 7 34 4 62 5 5 1 62 5 56 9 48 5 40 0 31 6 62 62 0 4 3 62 0 62 0 62 0 53 7 45 4 37 1 57 5 4 9 57 5 57 5 57 5 49 0 40 6 32 2 57 60 5 4 2 60 5 60 5 60...

Page 21: ...6 0 44 9 44 9 44 6 37 1 29 6 22 1 41 4 6 5 41 4 41 4 41 4 34 6 26 9 19 3 57 45 0 6 0 45 0 45 0 44 3 36 8 29 4 21 9 41 7 6 6 41 7 41 7 41 2 33 8 26 0 18 3 1925 72 53 1 6 5 46 0 37 8 29 7 21 6 48 4 7 1...

Page 22: ...atic Pressure Inch Water Gauge 0 2 0 4 0 6 0 8 1 0 SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM 024 2 0 DNZ Low 1 719 115 752 617 130 858 Low Medium 2 781 137 789 691 155 891 Medium 3 902 18...

Page 23: ...atic Pressure Inch Water Gauge 0 2 0 4 0 6 0 8 1 0 SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM SCFM W RPM 024 2 0 DNZ Low 1 719 115 752 617 130 858 Low Medium 2 781 137 789 691 155 891 Medium 3 902 18...

Page 24: ...00 0 06 0 02 0 16 1300 0 07 0 03 0 17 036 3 0 DNZ DNY DNX 700 0 01 0 00 0 04 800 0 02 0 01 0 06 900 0 03 0 01 0 08 1000 0 04 0 01 0 10 1100 0 05 0 01 0 13 1200 0 06 0 02 0 16 1300 0 07 0 03 0 17 1400...

Page 25: ...110 2220 D072 700 1350 1110 2220 DNX N065 685 1350 1080 2370 N090 685 1350 1070 1780 D090 685 1350 1070 1780 042 3 5 DNZ N065 1050 1750 1080 2370 N090 1050 1750 1070 1780 D090 1050 1750 1070 1780 048...

Page 26: ...ed at lower voltages Nominal Applied 240 208 0 75 230 0 92 480 460 0 92 600 575 0 92 Outdoor Sound Power Levels Size Tons Model Sound Rating1 dB A 1 Rated in accordance with ARI 270 standard Octave Ba...

Page 27: ...each OD Fan Motors each Supply Blower Motor MCA1 Amps 1 Minimum Circuit Ampacity Max Fuse2 Breaker3 Size Amps 2 Maximum Over Current Protection per standard UL 1995 3 Fuse or HACR circuit breaker siz...

Page 28: ...333491 YTG B 0807 Unitary Products Group 43 Typical DNX DNY DNZ024 060 Wiring Diagrams Typical DNZ024 060 Cooling Unit with Single Stage Gas Heat 208 230 1 60 volt Wiring Diagram...

Page 29: ...333491 YTG B 0807 44 Unitary Products Group Typical DNZ024 060 Cooling Unit with Two Stage Gas Heat 208 230 1 60 volt Wiring Diagram...

Page 30: ...333491 YTG B 0807 Unitary Products Group 49 Typical DNZ030 060 Cooling Unit with Single Stage Gas Heat 208 230 3 60 volt Wiring Diagram...

Page 31: ...333491 YTG B 0807 50 Unitary Products Group Typical DNZ030 060 Cooling Unit with Two Stage Gas Heat 208 230 3 60 volt Wiring Diagram...

Page 32: ...333491 YTG B 0807 Unitary Products Group 55 Typical DNZ030 060 Cooling Unit with Single Stage Gas Heat 460 3 60 volt Wiring Diagram...

Page 33: ...333491 YTG B 0807 56 Unitary Products Group Typical DNZ030 060 Cooling Unit with Two Stage Gas Heat 460 3 60 volt Wiring Diagram...

Page 34: ...5 400 20 24 5 116 84 84 117 DNX 445 440 20 24 5 127 93 93 127 030 2 5 DNZ 395 390 24 24 75 98 99 97 96 036 3 0 DNZ 400 395 24 25 100 101 98 96 DNY 445 440 20 24 25 126 91 93 129 DNX 485 480 20 24 136...

Page 35: ...ance in Top3 3 Units must be installed outdoors Over hanging structure or shrubs should not obscure condenser air discharge outlet 36 Right 12 Front 36 Left 24 Rear 0 Bottom4 4 Units may be installed...

Page 36: ...ions Front and Bottom Unit Dimensions Back and Bottom 5217 6 6833 12 287 137 211 7 21 2 92 7 211 12 287 21 16 7 5 1 137 92 7 211 12 287 2 92 7 211 12 287 92 7 211 12 287 6 5 7851 5 23 1 1 27720 5 7851...

Page 37: ...on Ground Installation Gas Model Shown 522 85 167 7 21 5 5 8 7 522 85 167 7 21 27720 8 7 6 21 5281 167 7 21 MANUAL GAS SHUT OFF VALVE TO GAS SUPPLY LINE FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REA...

Page 38: ...Gas Model Shown Unit Accessory Dimensions Roof Curb1 1 8 Roof Curb also available 0 18 6 6 87 2 9 9 6833 6 211 7 6 7 02817 21 81 7 72 32 5 6833 72 6 6833 1 21752 5 1 72 1 225 7 50267 7 5 7851 5 8 7 68...

Page 39: ...G B 0807 66 Unitary Products Group Roof Curb Cross Section 81 7 6 5 2817 5 6 1 17 675 3 168 7 21 1 522 1 0 7 5 522 1 522 1 0 7 5 168 7 21 85 5 0 0 1 29 1 6 522 22 1 5 81 7 6 6 7 1 25 85 5 0 1 8 7 6833...

Reviews: