background image

036-21366-007-A-1205

Unitary Products Group

3

STANDARD FEATURES/BENEFITS

OPERATING EFFICIENCY - All units provide high operating 
efficiencies and have a minimum AFUE of 80% and SEER of 
13.0. All efficiencies exceed legislated minimum levels.

ON SITE FLEXIBILITY - All model sizes share a common, 
compact design cabinet in a single footprint. The installer has 
the flexibility of setting one curb and placing the proper ton-
nage unit on that curb after the internal load has been deter-
mined. Field convertible duct connections from side shot to 
down shot allows the installer to have greater flexibility with 
less inventory.

LOWER INSTALLATION COST - Installation time and costs 
are reduced by easy power and control wiring connections. 
The small base dimension means less space is required on 
the ground or roof, plus, the installer can fit this unit between 
the wheel wells of full size pick-up truck. All models are well 
under 500 pounds.

All units are completely wired, charged with R-22 and tested 
prior to shipment. Unique test stations using a new state of the 
art computerized process system are used to insure product 
quality. Refrigerant charge and component part numbers are 
verified via computers at assembly. Vital run test statistics 
such as system pressure, motor currents, air velocity and tem-
perature, unit vibration, and gas system safeties are monitored 
and recorded by the system to insure unit performance.

Equal size, side supply and return duct connections allows 
easy hook-up of ducts to match low crawl spaces without 
transition pieces.

UTILITY CONNECTIONS MADE EASY - Gas and electric 
utility knockouts are provided through the bottom as well as 
the side of the unit. Utility connections can be made quickly 
and with a minimum amount of field labor. A field supplied 
and field installed electrical disconnect switch must be 
installed.

CONVERTIBLE AIRFLOW DESIGN - The bottom duct open-
ings are covered when they leave the factory ready to be 
used for a side supply / side return application. If a bottom 
supply / bottom return application is desired, you simply 
remove the two panels from the bottom of the unit and place 
them in the side supply / side return duct openings. No panel 
cutting is required and no accessory panel is necessary. 
Convertible airflow design allows maximum field flexibility and 
minimum inventory.

CONDENSATE PAN - A non-corrosive, long-lasting, water-
tight pan is positioned below the evaporator coil to collect and 
drain all condensate. Less collection of stagnate condensate 

will build-up. The condensate pan conforms to ASHRAE 62-
89 standards (Ventilation for Acceptable Indoor Air Quality).

CONDENSATE DRAIN - The heavy duty, 3/4 inch NPTI cop-
per connection is more durable over time. The connection is 
rigidly mounted to assure proper fit and leak tight seal.

DURABLE FINISH - With a heavy duty cabinet made of pow-
der-painted, galvanized steel the neutral color blends into 
surrounding areas. The powdered paint provides a better 
paint to steel bond, which resists corrosion and rust creep. 
The special primer formulas and glossy finish insures less 
fading when exposed to sunlight and offers a more attractive 
on site appearance. This paint finish meets ASTM-B117 stan-
dards for 1000 hours salt spray rating. The highest in the 
industry.

FULL PERIMETER BASE RAILS - The easily removable 
base rails provide a solid foundation for the entire unit and 
protects the unit during shipment. The rails provide fork lift 
access from all sides, and rigging holes are also provided so 
that an overhead crane can be used to place the units on a 
roof. On applications where the unit is placed on a pad, the 
base will keep the unit off the pad to deter corrosion. On 
applications where height is limited, the inch high base rails 
may be removed on location.

MORE ATTRACTIVE APPEARANCE - A single piece Water 
Shed top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation and 
provides a wider variety of installations. The one piece design 
adds greater water integrity. Rounded corners with water drip 
edges add to the attractive appearance. The cabinet panels 
have a non-fibrous insulation that will not release insulation 
fibers into conditioned area.

TOP DISCHARGE - The top discharge condenser fan does 
not disrupt neighboring areas or dry-out vegetation surround-
ing the unit. The warm air from the top mounted fan is blown 
up away from the structure and any landscaping. This allows 
compact location on multi-unit applications.

CONDENSER COIL GRILLE - A multi-piece totally enclosed, 
rigidly mounted condenser coil grille provides protection from 
objects after installation and provides protection during transit.

LOW OPERATING SOUND LEVEL - The upward air flow 
carries the normal operating noise up and away from the liv-
ing area. The rigid top panel effectively isolates any motor 
sound. Isolator mounted compressor and the rippled fins of 
the condenser coil muffle the normal fan motor and compres-
sor operating sounds. The unique formed base pan also aids 
in sound alterations with it's Super-Structure design. This 
design strategically places embossments in the pan for opti-
mum strength and rigidity.

Summary of Contents for Affinity DNP024

Page 1: ...ot surface to pilot ignition They are avail able in natural gas with field conversion to propane FEATURING FACTORY MOUNTED TXV COOLING GAS HEATING UNITS NATURAL GAS OR PROPANE LOW PROFILE QUIET OPERAT...

Page 2: ...0 POWER SUPPLY 29 19 TYPICAL WIRING DIAGRAM D NP 030 048 460 575 3 60 POWER SUPPLY 30 20 TYPICAL WIRING DIAGRAM D NP 060 460 575 3 60 POWER SUPPLY 31 21 TYPICAL WIRING DIAGRAM LEGEND 32 LIST OF TABLES...

Page 3: ...n of stagnate condensate will build up The condensate pan conforms to ASHRAE 62 89 standards Ventilation for Acceptable Indoor Air Quality CONDENSATE DRAIN The heavy duty 3 4 inch NPTI cop per connect...

Page 4: ...starts in damp condi tions MULTI PORT IN SHOT BURNERS No field adjustment is required to mix the air and gas These burners are con structed of high grade corrosion resistant aluminized steel LOW MAINT...

Page 5: ...H AIR DAMPER Designed for duct mounted side supply return and unit mounted down supply return applications Damper capable of providing 0 through 50 of outdoor air field supplied Closes on power loss i...

Page 6: ...LE 1 PHYSICAL DATA MODEL DNP 024 030 036 042 048 060 EVAPORATOR BLOWER CENTRIFUGAL BLOWER Dia x W in 10 x 8 10 x 8 11 x 10 12 x 11 12 x 11 12 x 11 FAN MOTOR HP 1 2 3 4 3 4 1 1 1 EVAPORATOR COIL ROWS D...

Page 7: ...42N09025 44 13 7 10 65 80 108 86 80 8 4 45 75 042N09046 44 13 7 10 65 80 108 86 80 8 4 45 75 042N09058 44 13 7 10 65 80 108 86 80 8 4 45 75 048N06506 48 13 2 11 7 84 80 64 80 8 3 25 55 048N06525 48 13...

Page 8: ...16 4 13 4 10 4 57 23 6 2 01 23 6 23 6 23 6 20 6 17 6 14 7 11 7 22 3 2 14 22 3 22 3 22 3 19 4 16 4 13 4 10 4 AIR ON EVAPORATOR COIL TEMPERATURE OF AIR ON CONDENSER COIL TEMPERATURE OF AIR ON CONDENSER...

Page 9: ...17 0 2 5 17 0 17 0 16 0 14 0 12 0 10 0 7 9 57 17 2 2 5 17 2 17 2 16 2 14 2 12 1 10 1 8 1 800 72 20 1 2 6 16 0 13 7 11 3 9 0 6 7 N A N A 67 18 1 2 5 18 9 17 9 15 5 13 2 10 9 8 5 6 2 62 17 7 2 5 17 7 17...

Page 10: ...ERINPUT kW 2 9 2 9 2 9 2 9 3 1 3 1 3 0 3 0 Sensible Capacity MBH 1 Entering Dry Bulb F 86 22 6 27 6 27 3 27 3 26 4 29 4 28 3 28 3 83 19 6 25 1 27 3 27 3 22 6 28 6 28 3 28 3 80 16 7 22 2 26 4 26 8 18 9...

Page 11: ...POWER INPUT kW 3 61 3 61 3 5 3 48 3 73 3 72 3 61 3 59 Sensible Capacity MBH 1 Entering Dry Bulb F 86 27 6 33 6 33 9 33 6 29 9 35 1 34 8 34 5 83 24 1 30 1 33 9 33 6 26 32 4 34 8 34 5 80 20 6 26 6 32 32...

Page 12: ...R 4 2 4 1 4 1 4 0 4 6 4 5 4 6 4 5 Sensible Capacity MBH 1 Entering Dry Bulb F 86 31 3 38 0 37 2 37 2 34 9 42 3 41 4 41 5 83 27 4 34 1 37 2 37 2 30 6 38 0 41 4 41 5 80 23 5 30 2 36 2 36 7 26 2 33 6 40...

Page 13: ...TOTAL POWER INPUT kW 4 49 4 45 4 38 4 34 4 63 4 59 4 51 4 48 Sensible Capacity MBH 1 Entering Dry Bulb F 86 34 1 41 3 41 4 41 7 37 1 4 44 41 8 42 1 83 30 0 37 7 40 7 41 1 32 4 40 6 41 8 42 1 80 26 0 3...

Page 14: ...R INPUT kW 5 52 5 43 5 34 5 27 5 69 5 60 5 51 5 43 Sensible Capacity MBH 1 Entering Dry Bulb F 86 37 1 45 3 49 5 49 3 42 6 51 8 50 2 50 0 83 32 7 40 9 48 4 49 3 37 2 46 4 50 2 50 0 80 28 4 36 6 44 1 4...

Page 15: ...8 SIDE SUPPLY AIR BLOWER PERFORMANCE 230 VOLT 024 HI 929 491 809 473 688 454 MED 999 353 944 338 865 319 785 299 706 280 LOW 998 372 906 333 813 294 721 255 651 241 BOTTOM SUPPLY AIR BLOWER PERFORMANC...

Page 16: ...410 457 504 575 646 687 729 780 830 042 COOLING FIELD SETTING 1500 450 500 553 641 729 798 830 872 939 042 HEATING 3 TUBE FACTORY SETTING 1500 450 500 553 641 729 798 830 872 939 042 HEATING 4 TUBE F...

Page 17: ...0 410 457 504 575 646 687 729 780 830 042 COOLING FIELD SETTING 1500 450 500 553 641 729 798 830 872 939 042 HEATING 3 TUBE FACTORY SETTING 1500 450 500 553 641 729 798 830 872 939 042 HEATING 4 TUBE...

Page 18: ...ing full economizer operation TABLE 13 ADDITIONAL STATIC PRESSURE RESISTANCE 3 1 2 4 AND 5 TON DESCRIPTION RESISTANCE IWG CFM 1 100 1 200 1 300 1 400 1 500 1 600 1 700 1 800 1 900 2 000 WET EVAPORATOR...

Page 19: ...253 8 6 55 1 1 6 8 18 7 25 25 0 96 75 030 460 3 60 432 504 5 7 39 0 6 6 8 13 4 20 20 0 96 75 036 208 230 1 60 187 253 17 2 88 1 1 6 8 29 4 45 45 0 96 40 036 208 230 3 60 187 253 11 4 77 1 1 6 8 22 2...

Page 20: ...R I N L E T L O U V E R S F R O N T G A S E L E C T R I C C O N T R O L S E R V I C E A C C E S S C O M P A R T M E N T P A N E L O V E R A L L O V E R A L L All dimensions are in inches They are subj...

Page 21: ...ONDENSATE DRAIN 3 4 NPTI GAS SUPPLY 1 5 8 DIA KNOCKOUT 1 2 NPTI CONNECTION LOW VOLTAGE CONN DIA KNOCKOUT 8 7 1 3 4 1 5 2 9 9 1 6 1 5 3 1 2 1 3 4 1 3 4 1 5 4 1 4 1 2 3 1 2 3 3 8 1 4 1 2 2 8 3 8 1 4 1 2...

Page 22: ...L G A S S H U T O F F V A L V E R E T U R N A I R D U C T S U P P L Y A I R D U C T C O N T R O L W I R I N G T O I N D O O R T H E R M O S T A T T O P O W E R S U P P Y M A N U A L G A S S H U T O F...

Page 23: ...S T A L L A T I O N B O T T O M D U C T S L A B O N G R O U N D I N S T A L L A T I O N TABLE 17 UNIT WEIGHTS AND CENTER OF GRAVITY UNIT SIZE SHIPPING WEIGHT lbs OPERATING WEIGHT lbs CORNER WEIGHTS lo...

Page 24: ...E N D E D D U C T S I Z E 1 7 1 8 X 2 1 1 2 R E C O M M E N D E D D U C T S I Z E 1 7 1 2 X 1 6 3 4 3 4 X 1 W I D E G A S K E T I N G F O R C U R B F R A M E A N D A L L D U C T S U P P O R T S U R F...

Page 25: ...036 21366 007 A 1205 Unitary Products Group 25 FIGURE 14 TYPICAL WIRING DIAGRAM D NP 024 208 230 1 60 POWER SUPPLY...

Page 26: ...L BOX T1 CONTROL BOARD 1 2 S DI LEADS MOTOR UNUSED 4 3 2 1 C X XFMR CN1 6 5 4 3 2 1 OFF DELAY TB1 Y C R W Y G C SEC C 230 LUG GND LUG GND NOTES 4 SEE UNIT NAMEPLATE FOR MAXIMUM FUSE SIZE AND MINIMUM C...

Page 27: ...036 21366 007 A 1205 Unitary Products Group 27 FIGURE 16 TYPICAL WIRING DIAGRAM D NP 060 208 230 1 60 POWER SUPPLY...

Page 28: ...CB 1 2 S DI LEADS MOTOR UNUSED 4 3 2 1 C X XFMR CN1 6 5 4 3 2 1 OFF DELAY TB1 Y C R W Y G C SEC C 230 RC2 LUG GND T3 T2 T1 L3 L2 L1 B A M1 LUG GND NOTES 4 SEE UNIT NAMEPLATE FOR MAXIMUM FUSE SIZE AND...

Page 29: ...036 21366 007 A 1205 Unitary Products Group 29 FIGURE 18 TYPICAL WIRING DIAGRAM D NP 060 208 230 3 60 POWER SUPPLY...

Page 30: ...036 21366 007 A 1205 30 Unitary Products Group FIGURE 19 TYPICAL WIRING DIAGRAM D NP 030 048 460 575 3 60 POWER SUPPLY...

Page 31: ...036 21366 007 A 1205 Unitary Products Group 31 FIGURE 20 TYPICAL WIRING DIAGRAM D NP 060 460 575 3 60 POWER SUPPLY...

Page 32: ...ed to ASCT 3 If neither LR or ASCT are present Wire 202 Y is connect to M1 coil 7 Shunt contact also used with crankcase heater Optional FIGURE 21 TYPICAL WIRING DIAGRAM LEGEND Open all disconnects be...

Page 33: ...o add strength rigidity and aid in minimizing sound Full perimeter base rails shall be provided to assure reliable transit of equipment overhead rigging for truck access and proper sealing on roof cur...

Page 34: ...ard controls shall be capable of operation down to 45 F outdoor tempera ture Accessory low ambient kit shall be available for opera tion to 0 F ELECTRICAL REQUIREMENTS All unit power wiring shall ente...

Page 35: ...036 21366 007 A 1205 Unitary Products Group 35...

Page 36: ...o change without notice Printed in U S A 036 21366 007 A 1205 Copyright 2005 by Unitary Products Group All rights reserved Supersedes 036 21366 006 A 1005 Unitary 5005 Norman Products York OK Group Dr...

Reviews: