350154-YTG-B-0408
Johnson Controls Unitary Products
9
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO. CZH02411
INDOOR COIL MODEL NO.
FC48D + MV12D
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
550
600
650
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
18.6 19.9 18.9 21.7 23.9 19.0 19.9 19.1 21.8 24.4 19.4 20.0 19.3 22.0 24.9
S.C.
18.6 17.5 14.9 14.8 11.7 19.2 18.5 15.6 15.5 12.1 19.7 19.4 16.2 16.2 12.5
K.W.
0.76 0.75 0.76 0.74 0.74 0.75 0.75 0.75 0.73 0.74 0.75 0.75 0.75 0.73 0.74
75
T.C.
17.8 18.8 18.0 20.6 22.8 18.3 18.9 18.3 20.9 23.2 18.7 19.1 18.5 21.1 23.6
S.C.
17.9 17.1 14.5 14.4 11.3 18.4 17.9 15.1 15.1 11.8 18.9 18.6 15.8 15.9 12.2
K.W.
0.93 0.92 0.93 0.91 0.90 0.92 0.92 0.92 0.90 0.90 0.91 0.91 0.92 0.90 0.90
85
T.C.
17.1 17.6 17.1 19.5 21.6 17.5 17.9 17.4 19.9 22.0 17.9 18.2 17.7 20.2 22.3
S.C.
17.2 16.8 14.0 14.0 10.9 17.7 17.3 14.7 14.8 11.4 18.1 17.9 15.4 15.5 11.9
K.W.
1.09 1.09 1.09 1.08 1.06 1.08 1.08 1.09 1.07 1.06 1.07 1.08 1.08 1.06 1.05
95
T.C.
16.4 16.5 16.2 18.5 20.5 16.8 16.9 16.6 18.9 20.8 17.1 17.2 16.9 19.4 21.0
S.C.
16.5 16.4 13.6 13.7 10.5 17.0 16.8 14.3 14.4 11.1 17.4 17.2 15.0 15.1 11.7
K.W.
1.26 1.26 1.26 1.24 1.22 1.24 1.25 1.25 1.24 1.22 1.24 1.24 1.25 1.23 1.21
105
T.C.
15.3 15.4 14.9 17.0 19.0 15.7 15.8 15.2 17.3 19.1 16.0 16.2 15.5 17.7 19.3
S.C.
15.4 15.2 13.0 13.2 10.1 15.8 15.6 13.6 13.9 10.5 16.2 16.0 14.3 14.5 11.0
K.W.
1.48 1.49 1.49 1.47 1.45 1.47 1.48 1.48 1.47 1.45 1.46 1.47 1.48 1.46 1.45
115
T.C.
14.2 14.3 13.6 15.5 17.5 14.6 14.7 13.9 15.8 17.6 15.0 15.1 14.1 16.1 17.7
S.C.
14.4 14.1 12.4 12.8 9.6 14.7 14.5 13.0 13.4 10.0 15.1 14.9 13.5 13.9 10.4
K.W.
1.70 1.71 1.71 1.70 1.68 1.69 1.70 1.70 1.69 1.67 1.68 1.69 1.70 1.68 1.67
125
T.C.
13.1 13.2 12.3 14.0 15.9 13.5 13.6 12.5 14.3 16.0 13.9 14.0 12.7 14.5 16.1
S.C.
13.3 13.0 11.8 12.3 9.2 13.6 13.4 12.3 12.9 9.5 14.0 13.8 12.8 13.4 9.7
K.W.
1.92 1.93 1.93 1.92 1.91 1.91 1.92 1.93 1.91 1.90 1.91 1.91 1.92 1.91 1.90
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
AV36C
–
0.97 0.97 0.99
MV12B
FC/MC/PC35B
0.96 0.97 1.01
MV12B
FC/MC/PC35C
0.96 0.97 1.01
MV12B
FC/MC/PC35B
0.98 0.98 1.02
MV12B
FC/MC/PC35C
0.98 0.98 1.02
MV12D
FC/MC/PC48D
1.00 1.00 1.00
MV12D
UC48D
1.00 1.00 1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*A12
FC/MC/PC32A 0.91
0.91
0.98
PV9*A12
FC/MC/PC32A 0.96
0.96
1.02
P(C,V)9*B12
FC/MC/PC35B 0.95
0.95
0.99
P(C,V)9*B12
FC/MC/PC35C 0.95
0.95
0.99
PV8*A12
FC/MC/PC37A 0.92
0.92
0.98
PV9*A12
FC/MC/PC37A 0.98
0.99
1.03
P(C,V)9*B12
FC/MC/PC43B 0.96
0.96
0.99
P(C,V)9*B12
FC/MC/PC43C 0.96
0.96
0.99
P(C,V)9*B12
HC36B 0.95
0.95
0.99