2ET07700224 and 2ET04700224 are used. Standard in 
all BHX units.

Filter/Frame Kit (Single Phase Only)

 - Kit contains the 

necessary hardware to field install return air filters into the 
base unit. Pre-cut filter racks and appropriate cleanable 
standard size filters are shipped in one kit. The filter rack 
is suitable for either 1" or 2" filters. (1" filter is supplied) 
This kit is available for single phase horizontal or vertical 
duct application only. Standard in all 3 Phase models.

Motorized Fresh Air Damper

 - Designed for duct 

mounted side supply/return and unit mounted down 
supply/return applications. Damper capable of providing 
0% through 50% of outdoor air (field supplied). Closes on 
power loss, includes hood and screen assembly.

Rectangle To Round Adapters

 - Kit includes one supply 

and one return air rectangle to round duct adapter. 
Adapters are preformed and designed to fit over current 
duct openings on the base unit. Transition is from side 
square duct opening to 14" round duct opening.

Roof Curbs

 - NRCA approved curbs provide proper fit to 

base unit for rooftop installations. Curbs are designed to 
be assembled through hinge pins in each corner. Kit also 
provides seal strip to assure a water tight seal. 8 and 14 
inch high roof curbs are available.

Manual Outdoor Damper

 - Provides 0% through 50% 

outdoor air capability (field adjustable). Designed for duct 
mounted side supply/return applications. Includes hood 
and screen assembly.

Wall Thermostat

 - The units are designed to operate with 

24-volt electronic and electro-mechanical thermostats. All 
units can operate with single stage heat/single stage cool 
thermostats - with or without the economizer.

Low Ambient Kit

 - Kit provides necessary hardware to 

convert unit to operate in cooling cycle down to 0º F. 
Standard unit operation 45º F.

Transformer Kit

 - Kit provides necessary hardware to 

provide single phase models from factory furnished 40 VA 
transformer capability to 75 VA transformer capability. 
(Required on installations with economizer or motorized 
damper.)

Guide Specifications

General

Units shall be manufactured by York International Unitary 
Products Group in an ISO 9001 certified facility. YORK’s 
Affinity™ package units give you the flexibility and choices you 
need in today’s market. These packaged heat pumps are 
designed for outdoor installation. Only utility and duct 
connections are required at the point of installation.

Description

Units shall be factory-assembled, single packaged, heat pump 
units, designed for outdoor mounted installation. For SEER 

ratings, refer to technical literature. They shall have built in, 
equal size, field convertible duct connections for down 
discharge supply/return or horizontal discharge supply/return. 
The units shall be factory wired, piped, charged with R-410A 
Refrigerant and factory tested prior to shipment. All unit wiring 
shall be both numbered and color coded. All units shall be 
manufactured in a facility certified to ISO 9001 standards, and 
the cooling performance shall be rated in accordance with DOE 
and ARI test procedures. The heating performance shall be 
rated to DOE and GAMA test procedures. Units shall be CSA 
listed and classified to ANSI Z21.47/CAN/CSA 2.3 standards 
and UL 1995/CAN/CSA No. 236-M90 conditions.

Unit Cabinet

Unit cabinet shall be constructed of G90 galvanized steel, with 
exterior surfaces coated with a non-chalking, powdered paint 
finish, certified at 1000 hours salt spray test per ASTM-B117 
standards. The unit top shall be a single piece “Water Shed” 
design, with drip edges and no-seam corners to provide 
optimum water integrity. Unit shall have a rigidly mounted 
condenser coil guard to provide protection from objects and 
personnel after installation. Indoor blower section shall be 
insulated with up to 3/4” thick, aluminum, foil faced insulation, 
fastened to prevent insulation from entering the air stream. 
Cabinet panels shall be “large” size, easily removable for 
servicing and maintenance, with built-in lift handles. Unit shall 
be built on a formed, “Super-Structure” design base pan, with 
embossments at critical points to add strength, rigidity and aid 
in minimizing sound. Full perimeter base rails shall be provided 
to assure reliable transit of equipment, overhead rigging, for 
truck access and proper sealing on roof curb applications. Base 
rails shall be removable, when required, to lower unit height. 
Filters shall be furnished and be accessible through a 
removable access door, sealed airtight. Units vertical discharge 
and return duct configuration shall be designed to fit between 
standard 24” O.C. beams without modification to building 
structure, duct work and base unit. Condensate pan shall be 
internally sloped and conform to ASHRAE 62-89 self-draining 
standards, with 3/4” NPTI copper, ridged mount connection.

Indoor (Evaporator) Fan Assembly

Fan shall be direct drive design. Fan wheel shall be double-inlet 
type with forward-curved blades, dynamically balanced to 
operate smoothly throughout the entire range of operation. 
Airflow design shall be constant air volume. Bearings shall be 
sealed and permanently lubricated for longer life and no 
maintenance. Fan assembly shall be “Slip Track” (slide-out) 
design for easy removal and cleaning.

Outdoor (Condenser) Fan Assembly

The outdoor fan shall be of the direct-driven propeller type, 
discharge air vertically, have aluminum blades riveted to 
corrosion resistant steel spider bracket and shall be statically 
balanced for smooth operation. The outdoor fan motor shall be 
totally enclosed with permanently lubricated bearings and 
internally protected against overload conditions.

Summary of Contents for AFFINITY BHX Series

Page 1: ...pumps are designed for outdoor installation Only utility and duct connections are required at the point of installation Field installed electric heater accessories are available to provide electric h...

Page 2: ...ensions 49 Component Location Heat Pump Direct Drive Condenser Fan Motor Highly Efficient Enhanced Copper Tube Aluminum Fin Indoor Coil Highly Efficient Enhanced Copper Tube Aluminum Fin Outdoor Coil...

Page 3: ...ottom supply bottom return application is desired you simply remove the two panels from the bottom of the unit and place them in the side supply side return duct openings No panel cutting is required...

Page 4: ...alve and a temperature sensor which protect the compressor if undesirable operating conditions occur Pressure Switches High pressure and low pressure loss of charge switches standard in all units When...

Page 5: ...r horizontal discharge supply return The units shall be factory wired piped charged with R 410A Refrigerant and factory tested prior to shipment All unit wiring shall be both numbered and color coded...

Page 6: ...orator coil shall be of the direct expansion blow through design while condenser coil shall be draw through design Refrigerant Circuit and Refrigerant Safety Components shall include a Shall include i...

Page 7: ...1 CONDENSER COIL DATA Face area Sq Ft 11 7 11 7 11 7 16 4 16 4 16 4 Rows 1 1 2 2 2 2 Fins per inch 20 20 20 20 20 20 Tube diameter in 3 8 3 8 3 8 3 8 3 8 3 8 Circuitry Type Interlaced Interlaced Inte...

Page 8: ...2 spd Scroll 2 spd Quantity 1 1 1 1 CONDENSER COIL DATA Face area Sq Ft 11 7 11 7 16 4 16 4 Rows 1 2 2 2 Fins per inch 20 20 20 20 Tube diameter in 3 8 3 8 3 8 3 8 Circuitry Type Interlaced Interlace...

Page 9: ...60 187 252 125 208 230 3 60 187 252 125 460 3 60 432 504 125 BHX 208 230 1 60 187 252 115 208 230 3 60 187 252 115 460 3 60 432 504 115 042 3 5 BHZ 208 230 1 60 187 252 125 208 230 3 60 187 252 125 46...

Page 10: ...9 5 1000 72 28 3 1 7 26 6 21 6 16 7 11 7 26 2 1 9 24 7 19 7 14 8 9 8 67 26 1 1 7 26 1 24 1 19 0 14 0 9 0 24 8 1 9 24 8 23 8 18 9 13 9 8 9 62 24 2 1 7 24 2 24 2 24 0 19 1 14 1 9 1 23 0 1 9 23 0 23 0 2...

Page 11: ...5 17 4 17 4 17 7 13 8 9 9 6 0 15 6 2 7 15 6 15 6 15 6 12 4 8 6 4 7 57 18 0 2 5 18 0 18 0 17 2 13 3 9 4 5 5 16 3 2 8 16 3 16 3 15 5 11 6 7 7 3 8 900 72 20 7 2 6 20 0 16 2 11 8 7 3 19 3 2 9 19 3 15 9 11...

Page 12: ...15 3 34 3 2 8 32 5 26 3 20 1 13 9 67 34 6 2 6 34 6 34 6 26 2 20 0 13 8 31 5 2 7 31 5 31 5 25 5 19 3 13 1 62 32 6 2 3 32 6 32 6 32 6 26 4 20 2 13 9 28 6 2 6 28 6 28 6 28 6 22 4 16 1 9 9 57 30 7 2 4 30...

Page 13: ...22 2 22 0 17 1 12 3 7 4 20 7 3 5 20 7 20 7 20 5 15 6 10 8 5 9 57 20 3 3 3 20 3 20 3 20 1 15 3 10 4 5 6 17 4 3 6 17 4 17 4 17 2 12 4 7 5 2 6 1125 72 28 6 3 3 26 5 21 0 15 4 9 9 26 9 3 6 25 5 20 0 14 4...

Page 14: ...3 0 39 0 31 5 24 1 16 6 67 40 8 2 5 40 8 40 8 33 9 26 5 19 0 37 9 2 9 37 9 37 9 32 5 25 1 17 6 62 37 7 2 5 37 7 37 7 37 7 30 3 22 8 15 4 35 4 2 8 35 4 35 4 35 4 28 0 20 5 13 1 57 37 3 2 5 37 3 37 3 3...

Page 15: ...3 3 8 26 3 26 3 27 4 21 6 15 8 9 9 23 5 4 2 23 5 23 5 23 5 18 7 12 9 7 0 57 26 4 3 8 26 4 26 4 27 5 21 7 15 9 10 0 23 7 4 2 23 7 23 7 23 7 18 9 13 1 7 3 1350 72 31 3 4 0 30 7 25 2 18 6 12 0 28 1 4 4...

Page 16: ...3 5 42 8 34 1 25 4 16 7 67 44 4 3 3 44 4 43 6 34 9 26 2 17 5 44 1 3 5 44 1 43 0 34 3 25 6 16 9 62 43 6 3 2 43 6 43 6 43 6 34 9 26 2 17 5 41 6 3 4 41 6 41 6 41 6 32 9 24 2 15 5 57 43 1 3 2 43 1 43 1 43...

Page 17: ...29 4 4 3 29 4 29 4 31 2 24 4 17 6 10 8 25 8 4 7 25 8 25 8 27 3 20 5 13 7 6 9 57 30 6 4 3 30 6 30 6 31 3 24 5 17 7 10 9 26 7 4 8 26 7 26 7 27 9 21 1 14 3 7 5 1575 72 36 2 4 4 35 5 28 5 20 7 13 0 31 7 4...

Page 18: ...4 2 50 0 40 5 31 0 21 5 67 54 3 3 8 54 3 54 3 43 7 34 2 24 7 49 7 4 1 49 7 49 7 41 0 31 5 22 0 62 47 9 3 8 47 9 47 9 47 9 38 4 28 9 19 4 45 4 4 0 45 4 45 4 45 4 35 9 26 4 16 9 57 49 1 3 8 49 1 49 1 49...

Page 19: ...35 7 4 7 35 7 35 7 35 2 27 5 19 7 11 9 31 9 5 1 31 9 31 9 31 5 23 8 16 0 8 2 57 35 7 4 7 35 7 35 7 35 3 27 6 19 8 12 0 32 1 5 2 32 1 32 1 31 7 23 9 16 1 8 3 1800 72 42 1 5 0 40 8 33 3 24 4 15 6 37 9 5...

Page 20: ...5 1 63 0 50 6 38 2 25 8 67 66 9 4 6 66 9 66 2 51 4 39 0 26 5 62 3 5 0 62 3 62 0 49 6 37 1 24 7 62 65 2 4 1 65 2 65 2 65 2 52 8 40 4 28 0 59 0 4 7 59 0 59 0 59 0 46 6 34 2 21 7 57 64 5 4 1 64 5 64 5 64...

Page 21: ...3 6 1 41 3 41 3 45 1 35 4 25 6 15 9 36 3 6 6 36 3 36 3 36 3 33 3 23 5 13 8 57 43 2 6 1 43 2 43 2 41 8 32 1 22 4 12 7 39 4 6 6 39 4 39 4 38 2 28 5 18 8 9 1 2250 72 50 7 6 5 48 8 38 3 27 2 16 2 45 8 7...

Page 22: ...62 25 3 1 6 25 3 25 3 24 8 21 1 17 4 13 8 23 6 1 8 23 6 23 6 23 2 19 5 15 8 12 1 57 25 0 1 6 25 0 25 0 25 1 21 4 17 8 15 0 23 6 1 8 23 6 23 6 23 4 19 7 16 0 12 7 95 F 105 F 600 77 22 4 1 4 15 5 10 2 7...

Page 23: ...9 25 9 21 0 34 2 2 6 34 2 34 2 33 9 28 9 23 9 18 9 57 36 6 2 3 36 6 36 6 36 5 31 5 26 6 23 9 34 3 2 6 34 3 34 3 34 2 29 2 24 2 20 4 95 F 105 F 900 77 31 5 2 0 22 4 14 2 10 1 28 3 2 2 23 1 14 7 9 0 72...

Page 24: ...5 6 28 7 46 5 3 9 46 5 46 5 46 5 39 5 32 6 25 6 57 53 5 3 6 53 5 53 5 48 8 41 9 35 0 32 8 50 5 3 9 50 5 50 5 46 0 39 0 32 1 27 4 95 F 105 F 1050 77 39 9 2 7 24 0 17 8 12 7 36 8 3 1 23 8 16 4 11 6 72 3...

Page 25: ...0 2 33 6 55 6 4 5 55 6 55 6 51 2 44 4 37 7 30 9 57 57 6 4 1 57 6 57 6 56 3 49 7 43 1 40 3 54 6 4 6 54 6 54 6 53 3 46 5 39 8 34 9 95 F 105 F 1200 77 48 5 3 5 25 9 20 6 15 3 44 5 3 9 23 4 18 6 14 0 72 4...

Page 26: ...2 13 40 16 61 20 73 26 06 32 93 KW 1 49 1 57 1 64 1 72 1 79 1 87 1 94 2 02 80 MBH 6 33 7 83 9 75 12 23 15 43 19 56 24 88 31 75 KW 1 67 1 74 1 82 1 89 1 97 2 04 2 12 2 19 030 2 5 750 55 MBH 12 14 13 95...

Page 27: ...33 69 40 46 KW 2 44 2 61 2 77 2 94 3 11 3 28 3 45 3 62 042 3 0 1050 55 MBH 14 34 17 01 20 13 23 79 28 08 33 09 38 97 45 85 KW 2 20 2 43 2 66 2 89 3 12 3 34 3 57 3 80 70 MBH 14 60 17 27 20 39 24 05 28...

Page 28: ...54 28 20 32 46 37 44 43 23 49 98 57 85 67 02 KW 3 12 3 34 3 56 3 79 4 01 4 23 4 45 4 67 70 MBH 22 90 26 57 30 83 35 80 41 60 48 35 56 21 65 38 KW 3 56 3 78 4 00 4 22 4 44 4 66 4 89 5 11 80 MBH 21 74...

Page 29: ...9 69 34 80 40 85 KW 1 68 1 77 1 86 1 96 2 06 2 16 2 27 2 39 70 MBH 11 75 13 93 16 51 19 58 23 21 27 52 32 63 38 68 KW 2 16 2 25 2 34 2 44 2 54 2 64 2 75 2 87 80 MBH 7 25 9 43 12 02 15 08 18 72 23 02 2...

Page 30: ...140 160 181 Y1 W1 COOL C HEAT D 800 99 118 137 157 Y1 W1 COOL D HEAT A 900 127 146 167 188 Y1 W1 COOL D HEAT B 900 127 146 167 188 Y1 W1 COOL D HEAT C 900 127 146 167 188 Y1 W1 COOL D HEAT D 900 127 1...

Page 31: ...700 508 565 620 672 723 060 5 0 BHX Cool Low Y1 COOL A 1200 138 176 211 244 275 303 329 352 374 Y1 COOL B 1130 61 98 133 163 190 213 232 247 260 Y1 COOL C 1270 208 246 283 318 353 386 418 448 478 Y1 C...

Page 32: ...981 971 397 1048 Medium High 4 1416 413 872 1314 436 932 1206 454 993 1083 460 1051 High 5 1441 530 970 1326 538 1022 1182 521 1070 042 3 5 BHZ Low 1 1241 221 702 1151 245 778 1058 268 853 Low Medium...

Page 33: ...81 Y1 W1 COOL C HEAT D 800 99 118 137 157 Y1 W1 COOL D HEAT A 900 127 146 167 188 Y1 W1 COOL D HEAT B 900 127 146 167 188 Y1 W1 COOL D HEAT C 900 127 146 167 188 Y1 W1 COOL D HEAT D 900 127 146 167 18...

Page 34: ...700 508 565 620 672 723 060 5 0 BHX Cool Low Y1 COOL A 1200 138 176 211 244 275 303 329 352 374 Y1 COOL B 1130 61 98 133 163 190 213 232 247 260 Y1 COOL C 1270 208 246 283 318 353 386 418 448 478 Y1 C...

Page 35: ...981 971 397 1048 Medium High 4 1416 413 872 1314 436 932 1206 454 993 1083 460 1051 High 5 1441 530 970 1326 538 1022 1182 521 1070 042 3 5 BHZ Low 1 1241 221 702 1151 245 778 1058 268 853 Low Medium...

Page 36: ...0 03 0 06 1300 0 07 0 03 0 17 036 3 0 BHZ BHX 700 0 01 0 00 0 02 0 03 800 0 01 0 01 0 02 0 03 900 0 01 0 01 0 02 0 04 1000 0 02 0 01 0 02 0 04 1100 0 03 0 01 0 03 0 05 1200 0 04 0 02 0 03 0 06 1300 0...

Page 37: ...HZ BHX 1 2 Variable 0 8 1 0 48 030 2 5 BHZ 1 2 Variable 0 8 1 0 48 036 3 0 BHZ BHX 3 4 Variable 0 8 1 0 48 042 3 5 BHZ 3 4 Variable 0 8 1 0 48 048 4 0 BHZ BHX 3 4 Variable 0 8 1 0 48 060 5 0 BHZ BHX 1...

Page 38: ...1 18 32 7 35 042 3 5 208 230 1 60 18 6 105 29 1 2 6 0 None 30 5 40 2NP04501006 7 5 10 2 36 1 41 7 75 6 82 5 80 90 2NP04501506 11 3 15 2 54 2 62 5 98 2 108 6 100 110 2ND04501506 3 8 5 1 18 1 20 8 53 56...

Page 39: ...0 208 230 1 60 21 1 96 33 2 6 6 8 None 35 8 45 2NP04501006 7 5 10 2 36 1 41 7 80 9 87 9 90 90 2NP04501506 11 3 15 2 54 2 62 5 103 5 113 9 110 125 2NP04502006 15 20 2 72 2 83 3 126 1 139 9 150 150 2NP0...

Page 40: ...333495 YTG A 0407 40 Unitary Products Group Typical BHX BHZ024 060 Wiring Diagrams Typical BHX024 048 and 060 Heat Pump 208 230 1 60 volt Wiring Diagram...

Page 41: ...333495 YTG A 0407 Unitary Products Group 41 Typical BHX036 Heat Pump 208 230 1 60 volt Wiring Diagram...

Page 42: ...333495 YTG A 0407 42 Unitary Products Group Typical BHZ024 060 Heat Pump 208 230 1 60 volt Wiring Diagram...

Page 43: ...333495 YTG A 0407 Unitary Products Group 43 Typical BHX048 and 060 Heat Pump 230 3 60 volt Wiring Diagram...

Page 44: ...333495 YTG A 0407 44 Unitary Products Group Typical BHX036 Heat Pump 230 3 60 volt Wiring Diagram...

Page 45: ...333495 YTG A 0407 Unitary Products Group 45 Typical BHZ030 060 Heat Pump 230 3 60 volt Wiring Diagram...

Page 46: ...333495 YTG A 0407 46 Unitary Products Group Typical BHX048 and 060 Heat Pump 460 3 60 volt Wiring Diagram...

Page 47: ...333495 YTG A 0407 Unitary Products Group 47 Typical BHX036 Heat Pump 460 3 60 volt Wiring Diagram...

Page 48: ...333495 YTG A 0407 48 Unitary Products Group Typical BHZ030 060 Heat Pump 460 3 60 volt Wiring Diagram...

Page 49: ...25 96 84 81 93 036 3 0 BHZ 395 390 22 25 25 106 92 89 102 BHX 405 400 21 75 24 25 108 90 92 110 042 3 5 BHZ 445 440 22 25 25 120 104 101 115 048 4 0 BHZ 490 485 22 25 25 132 115 111 127 BHX 445 440 2...

Page 50: ...cture or shrubs should not obscure condenser air discharge outlet 36 Right 24 Front 12 Left 24 Rear 0 Bottom2 3 2 Units may be installed on combustable floors made from wood or class A B or C roof cov...

Page 51: ...ions Front and Bottom Unit Dimensions Back and Bottom 5217 6 6833 12 287 137 211 7 21 2 92 7 211 12 287 21 16 7 5 1 137 92 7 211 12 287 2 92 7 211 12 287 92 7 211 12 287 6 5 7851 5 23 1 1 27720 5 7851...

Page 52: ...pplications Unit Typical Slab on Ground Installation 522 85 167 7 21 5 5 8 7 522 85 167 7 21 27720 8 7 6 21 5281 167 7 21 TO POWER SUPPLY SUPPLY AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWIT...

Page 53: ...tion Unit Accessory Dimensions Roof Curb1 1 8 Roof Curb also available SUPPLY AIR DUCT RETURN AIR DUCT CONTROL WIRING TO INDOOR THERMOSTAT TO POWER SUPPLY FIELD SUPPLIED DISCONNECT SWITCH MOUNTED ON U...

Page 54: ...G A 0407 54 Unitary Products Group Roof Curb Cross Section 81 7 6 5 2817 5 6 1 17 675 3 168 7 21 1 522 1 0 7 5 522 1 522 1 0 7 5 168 7 21 85 5 0 0 1 29 1 6 522 22 1 5 81 7 6 6 7 1 25 85 5 0 1 8 7 6833...

Page 55: ...333495 YTG A 0407 Unitary Products Group 55...

Page 56: ...t to change without notice Printed in U S A 333495 YTG A 0407 Copyright 2007 by Unitary Products Group All rights reserved Supersedes 291625 YTG A 0207 Unitary 5005 Norman Products York OK Group Drive...

Reviews: