DESCRIPTION

These packaged cooling/heating air conditioners are 
designed for outdoor installation. Only utility and duct con-
nections are required at the point of installation.

The gas-fired heaters have aluminized steel tubular heat 
exchangers and spark to pilot ignition. They are available in 
natural gas with field conversion to propane.

STANDARD FEATURES/BENEFITS

OPERATING EFFICIENCY

 - All units provide high operating 

efficiencies and have a minimum AFUE of 80% and SEER of 
up to 12.4. All efficiencies exceed legislated minimum levels.

ON SITE FLEXIBILITY

 - All model sizes share a common, 

compact design cabinet in a single footprint. The installer has 
the flexibility of setting one curb and placing the proper ton-
nage unit on that curb after the internal load has been deter-
mined. Field convertible duct connections from side shot to 
down shot allows the installer to have greater flexibility with 
less inventory.

LOWER INSTALLATION COST

 - Installation time and costs 

are reduced by easy power and control wiring connections. 
The small base dimension means less space is required on 
the ground or roof, plus, the installer can fit this unit between 
the wheel wells of full size pick-up truck. All models are well 
under 500 pounds.

All units are completely wired, charged with R-22 and tested 
prior to shipment. Unique test stations using a new state of 
the art computerized process system are used to insure prod-
uct quality. Refrigerant charge, and component part numbers 
are verified via computers at assembly. Vital run test statistics 
such as system pressure, motor currents, air velocity and 
temperature, unit vibration, and gas system safeties are mon-
itored and recorded by the system to insure unit perfor-
mance.

Equal size, side supply and return duct connections allows 
easy hook-up of ducts to match low crawl spaces without 
transition pieces.

UTILITY CONNECTIONS MADE EASY

 - Gas and electric 

utility knockouts are provided through the bottom as well as 
the side of the unit. Utility connections can be made quickly 
and with a minimum amount of field labor. A field supplied 
and field installed electrical disconnect switch must be 
installed.

CONVERTIBLE AIRFLOW DESIGN

 - The bottom duct open-

ings are covered when they leave the factory ready to be 
used for a side supply / side return application. If a bottom 
supply / bottom return application is desired, you simply 
remove the two panels from the bottom of the unit and place 
them in the side supply / side return duct openings. No panel 
cutting is required and no accessory panel is necessary. 
Convertible airflow design allows maximum field flexibility and 
minimum inventory.

CONDENSATE PAN

 - A non-corrosive, long-lasting, water-

tight pan is positioned below the evaporator coil to collect and 
drain all condensate. Less collection of stagnate condensate 
will build-up. The condensate pan conforms to ASHRAE 62-
89 standards (Ventilation for Acceptable Indoor Air Quality).

CONDENSATE DRAIN

 - The heavy duty, 3/4 inch NPTI cop-

per connection is more tolerable during installation and is 
more durable over time. The connection is rigidly mounted to 
assure proper fit and leak tight seal.

DURABLE FINISH

 - With a heavy duty cabinet made of pow-

der-painted, galvanized steel the neutral color blends into 
surrounding areas. The powdered paint, provides a better 
paint to steel bond, which resists corrosion and rust creep. 
The special primer formulas and glossy finish insure less fad-
ing when exposed to sunlight and offers a more attractive on 
site appearance. This paint finish meets ASTM-B117 stan-
dards for 1000 hours salt spray rating. The highest in the 
industry.

FULL PERIMETER BASE RAILS

 - The easily removable 

base rails provide a solid foundation for the entire unit and 
protects the unit during shipment. The rails provide fork lift 
access from all sides, and rigging holes are also provided so 
that an overhead crane can be used to place the units on a 
roof. On applications where the unit is placed on a pad, the 
base will keep the unit off the pad to deter corrosion. On 
applications where height is limited, the inch high base rails 
may be removed on location.

MORE ATTRACTIVE APPEARANCE

 - A single piece Water 

Shed top cover containing a top discharge condenser fan 
arrangement requires less square footage on installation and 
provides a wider variety of installations. The one piece design 
adds greater water integrity. Rounded corners with water drip 
edges add to the attractive appearance. The cabinet panels 
have a non-fibrous insulation that will not release insulation 
fibers into conditioned area.

TOP DISCHARGE

 - The top discharge condenser fan does 

not disrupt neighboring areas or does this dry-out vegetation 
surrounding the unit. The warm air from the top mounted fan 
is blown up away from the structure and any landscaping. 
This allows compact location on multi-unit applications.

CONDENSER COIL GRILLE

 - A multi-piece totally enclosed, 

rigidly mounted condenser coil grille provides protection from 
objects after installation and provides protection during transit.

LOW OPERATING SOUND LEVEL

 - The upward air flow 

carries the normal operating noise up and away from the liv-
ing area. The rigid top panel effectively isolates any motor 
sound. Isolator mounted compressor and the rippled fins of 
the condenser coil muffle the normal fan motor and compres-
sor operating sounds. The unique formed base pan also aids 
in sound alterations with it's Super-Structure design. This 
design strategically places embossments in the pan for opti-
mum strength and rigidity.

Summary of Contents for AFFINITY 291627-YTG-B-0807

Page 1: ...g from residential to light commercial and any in between The Affinity is a unit that gives you the flexibility and choices you need in today s market FEATURING COOLING GAS HEATING UNITS NATURAL GAS O...

Page 2: ...TA 7 2 RATINGS COOLING GAS HEATING 8 3 DNH030 COOLING CAPACITIES 2 1 2 TON 9 4 DNH036 COOLING CAPACITIES 3 TON 10 5 DNH042 COOLING CAPACITIES 3 1 2 TON 11 6 DNH048 COOLING CAPACITIES 4 TON 12 7 DNH060...

Page 3: ...ENSATE PAN A non corrosive long lasting water tight pan is positioned below the evaporator coil to collect and drain all condensate Less collection of stagnate condensate will build up The condensate...

Page 4: ...g the system No final field mounting required EASY SERVICE ACCESS A large single panel covers the electrical and gas controls makes servicing easy The blower compartment has an additional large panel...

Page 5: ...screen assembly WALL THERMOSTAT The units are designed to operate with 24 volt electronic and electro mechanical thermostats All units can operate with single stage heat single stage cool thermostats...

Page 6: ...1 4 1 4 1 4 1 3 1 3 NOM CFM TOTAL 2 400 2 400 2 400 3 000 3 000 CONDENSER COIL ROWS DEEP 1 2 1 2 2 FINS PER INCH 20 20 20 20 20 FACE AREA Sq Ft 11 7 11 7 14 7 14 7 14 7 CHARGE REFRIGERANT 22 lbs oz 4...

Page 7: ...0 6 3 25 55 042N09025 42 0 12 0 80 108 87 80 8 4 45 75 042N09046 42 0 12 0 80 108 87 80 8 4 45 75 048N06525 48 0 12 0 84 80 64 80 8 3 25 55 048N06546 48 0 12 0 84 80 64 80 8 3 25 55 048N09025 48 0 12...

Page 8: ...MBH 1 Entering Dry Bulb F 86 16 0 19 6 19 4 19 0 18 4 22 3 21 4 20 9 20 8 24 9 23 3 22 8 22 3 25 0 23 4 22 9 23 7 25 2 23 5 23 0 83 13 9 18 0 19 4 19 0 15 9 20 6 21 4 20 9 17 9 23 2 23 3 22 8 18 9 23...

Page 9: ...20 6 25 9 28 3 28 3 23 0 28 9 30 5 30 6 25 3 31 8 32 6 32 9 25 2 32 0 33 2 33 4 25 1 32 2 33 7 33 9 83 18 9 24 2 27 9 27 8 21 0 26 9 30 3 30 4 23 2 29 7 32 6 32 9 23 6 30 4 33 2 33 4 24 0 31 1 33 7 33...

Page 10: ...F 86 24 8 31 0 29 9 29 5 28 2 34 9 32 7 32 2 31 6 38 7 35 5 35 0 34 0 39 1 36 2 34 8 36 3 39 4 35 0 34 5 83 21 8 28 0 29 9 29 5 24 7 31 6 32 7 32 2 27 5 35 3 35 5 35 0 29 3 36 8 35 2 34 8 31 1 38 4 35...

Page 11: ...6 31 8 39 0 39 9 39 9 34 3 41 4 40 8 40 7 36 9 43 8 41 6 41 5 40 3 45 7 42 8 42 8 43 8 47 6 44 1 44 0 83 28 4 35 7 38 9 39 0 30 3 38 0 40 2 40 3 32 2 40 3 41 6 41 5 35 0 43 3 42 8 42 8 37 9 46 2 44 1...

Page 12: ...6 41 8 51 8 53 0 51 7 43 6 54 0 53 8 52 6 45 5 56 2 54 6 53 4 47 1 56 7 54 3 56 1 48 7 57 3 54 0 52 8 83 36 9 47 0 52 2 51 7 38 4 48 9 53 4 52 6 39 9 50 7 54 6 53 4 41 2 52 3 54 3 53 1 42 5 53 8 54 0...

Page 13: ...1315 657 1204 623 1093 588 MED 1432 650 1381 628 1330 605 1279 583 1210 556 1140 529 LOW 1191 527 1149 510 1107 494 1065 477 048 HI 1742 898 1695 869 1648 841 1601 811 1555 781 1501 747 1446 714 1317...

Page 14: ...913 1706 888 1648 861 1590 834 1445 783 1301 731 MED 1734 848 1693 821 1651 794 1595 764 1539 734 1461 693 1382 653 1266 613 LOW 1532 700 1508 683 1458 667 1444 643 1404 620 1348 593 1291 566 060 only...

Page 15: ...1295 639 1147 600 MED 1482 628 1428 613 1374 599 1320 584 1242 556 1163 528 1085 500 LOW 1239 510 1184 496 1130 481 1075 467 048 HI 1655 771 1609 749 1563 727 1504 698 1444 670 1381 648 1319 626 MED 1...

Page 16: ...814 945 1731 905 1578 582 LOW 1937 990 1892 983 1846 935 1785 908 1723 880 1655 843 1587 805 060 3 tube only 230 460 volts HEAT 1500 245 1500 297 1500 348 1500 400 1500 470 1500 540 1500 610 1500 680...

Page 17: ...m the available external static pressure shown in Table 8 9 10 and 11 2 The pressure through the economizer is greater for 100 outdoor air then for 100 return air If the resistance of the return air d...

Page 18: ...504 4 3 27 0 6 1 4 7 4 15 15 96 75 036 208 230 3 60 187 253 11 4 77 1 1 3 5 18 9 25 25 96 75 036 460 3 60 414 504 5 7 39 0 6 1 8 9 5 15 15 96 75 042 208 230 3 60 187 253 13 9 88 1 3 3 5 22 2 30 30 96...

Page 19: ...I R I N L E T L O U V E R S F R O N T G A S E L E C T R I C C O N T R O L S E R V I C E A C C E S S C O M P A R T M E N T P A N E L O V E R A L L O V E R A L L All dimensions are in inches They are s...

Page 20: ...D R A I N 3 4 N P T I G A S S U P P L Y 1 5 8 D I A K N O C K O U T 1 2 N P T I C O N N E C T I O N L O W V O L T A G E C O N N 1 8 D I A K N O C K O U T 1 3 4 1 5 2 9 9 1 6 1 5 3 1 2 1 3 4 1 3 4 1 5...

Page 21: ...L G A S S H U T O F F V A L V E R E T U R N A I R D U C T S U P P L Y A I R D U C T C O N T R O L W I R I N G T O I N D O O R T H E R M O S T A T T O P O W E R S U P P Y M A N U A L G A S S H U T O F...

Page 22: ...U C T S L A B O N G R O U N D I N S T A L L A T I O N TABLE 17 UNIT WEIGHTS AND CENTER OF GRAVITY UNIT SIZE SHIPPING WEIGHT lbs OPERATING WEIGHT lbs CORNER WEIGHTS location lbs ECONOMIZER lbs ROOF CU...

Page 23: ...1 8 X 2 1 1 2 R E C O M M E N D E D D U C T S I Z E 1 7 1 2 X 1 6 3 4 1 8 Roof curb also available 3 4 X 1 W I D E G A S K E T I N G F O R C U R B F R A M E A N D A L L D U C T S U P P O R T S U R F A...

Page 24: ...291627 YTG B 0807 24 Unitary Products Group FIGURE 14 TYPICAL WIRING DIAGRAM DNH 030 036 042 048 208 230 3 60 POWER SUPPLY...

Page 25: ...291627 YTG B 0807 Unitary Products Group 25 FIGURE 15 TYPICAL WIRING DIAGRAM DNH 030 036 042 048 460 3 60 POWER SUPPLY...

Page 26: ...291627 YTG B 0807 26 Unitary Products Group FIGURE 16 TYPICAL WIRING DIAGRAM DNH 060 208 230 3 60 POWER SUPPLY...

Page 27: ...291627 YTG B 0807 Unitary Products Group 27 FIGURE 17 TYPICAL WIRING DIAGRAM DNH 060 460 3 60 POWER SUPPLY...

Page 28: ...If neither LR or ASCT are present wire 202 Y is connected to M1 coil as shown 7 Shunt contact also used with crankcase heater optional 8 Unit factory wired for low or medium speed indoor blower operat...

Page 29: ...otection from objects and personnel after installation Indoor blower section shall be insulated with up to 3 4 thick aluminum foil faced insulation fastened to prevent insulation from entering the air...

Page 30: ...nts brazed b Evaporator coil shall be of the direct expansion blow through design while condenser coil shall be draw through design Refrigerant Circuit and Refrigerant Safety Components a Shall includ...

Page 31: ...291627 YTG B 0807 Unitary Products Group 31...

Page 32: ...t to change without notice Printed in U S A 291627 YTG B 0807 Copyright 2007 by Unitary Products Group All rights reserved Supersedes 291627 YTG A 0207 Unitary 5005 Norman Products York OK Group Drive...

Reviews: