ELECTRIC HEATERS & OPERATING 

CONTROLS

LOW VOLTAGE CONTROL CONNECTIONS

The low voltage transformer and the fan control are standard on
all models.

The 24 volt power supply is provided by an internally wired low
voltage transformer which is standard on all air handler models.
Field supplied low voltage wiring can exit the unit on the top
right hand corner or the right hand side panel. Refer to Figure 1.
Remove desired knockout and pierce foil faced insulation to
allow wiring to pass through. Use as smallest hole possible to
minimize air leakage. Install a 7/8” plastic bushing in the
selected hole and keep low voltage wiring as short as possible
inside the control box. To further minimize air leakage, seal the
wiring entry point at the outside of the unit. The field wiring is to
be connected at the screw terminals of the control board.

For blower speed connections, electrical information and wir-
ing diagrams, see indoor unit installation instructions.

The electric heaters have both auto resettable and one shot
thermal limit controls.
If failure occurs, this one shot thermal limit control must be
replaced with a direct replacement.

NOTICE

NOTICE

All wiring must comply with local and national electrical code
requirements. Read and heed all unit caution labels.

NOTICE

FIGURE 4: 

Typical Installed Application

UPFLOW

HORIZONTAL RIGHT

HORIZONTAL LEFT

HEAT

HEA

T

HEA

T

DOWNFLOW

HEAT

Summary of Contents for 6HK Series

Page 1: ...the absence of local codes with National Electrical Code ANSI NFPA 70 1996 or current edi tion The information contained in this manual is intended for use by a qualified service technician familiar with safety proce dures and equipped with the proper tools and test instru ments Shut OFF electric power at unit disconnect and or service panel before beginning the following procedures Failure to car...

Page 2: ...el of air handler control and wiring compartment 4 Install electric heat accessory a Position and insert heat kit into opening in air handler b Align mount holes and fasten the Heat Kit to the air handler unit with 4 duct cover screws 5 Remove and discard the air handler power connection wir ing that is for use without electric heat the connector con taining only the red and black wires from the 6...

Page 3: ...806 6HK16501006 6HK16501306 Early version heat kits with 2 or 3 circuit breakers YES YES NO 6HK16501506 6HK16501806 6HK16502006 6HK16502506 6HK26501306 6HK26501506 6HK26501806 6HK26502006 6HK26502506 6HK16501306B Revision B heat kits with 2 or 3 circuit breakers YES YES YES 6HK16501506B 6HK16501806B 6HK16502006B 6HK16502506B 6HK26501306B 6HK26501506B 6HK26501806B 6HK26502006B 6HK26502506B 3 PH 6HK...

Page 4: ...de requirements Read and heed all unit caution labels NOTICE FIGURE 2 Heat Kit Connection FACTORY WIRING ATTACHED TO THIS SIDE Do not need to remove TERMINAL BLOCK OR CIRCUIT BREAKERS May be 1 2 or 3 FIELD SUPPLY WIRING WILL BE ATTACHED TO LEFT SIDE FIGURE 3 Supply Power Connection FIELD POWER WIRING 208 230V COMPONENT CODES GND GROUND LUG CB CIRCUIT BREAKER CKT CIRCUIT CN WIRE CONNECTOR NUT GND J...

Page 5: ...lastic bushing in the selected hole and keep low voltage wiring as short as possible inside the control box To further minimize air leakage seal the wiring entry point at the outside of the unit The field wiring is to be connected at the screw terminals of the control board For blower speed connections electrical information and wir ing diagrams see indoor unit installation instructions The electr...

Page 6: ...o change without notice Published in U S A 669997 UAI H 0514 Copyright 2014 by Johnson Controls Inc All rights reserved Supersedes 669997 UAI G 0413 York International Corp 5005 York Drive Norman OK 73069 NOTES ...

Reviews: