5320779-UIM-A-0417
12
Johnson Controls Unitary Products
FIGURE 11:
Thermostat Chart - Single Stage AC with PSC Furnace
A0166-002
AC 5E
Single Stage Air Conditioner
– Single Stage PSC Furnace
C
24 – Volt Common
Y
Compressor Contactor
SINGLE STAGE
AIR
CONDITIONER
SINGLE STAGE
AIR CONDITIONER
Y
Full Stage Compressor
G
Fan
*BP11C50124
*BN11C01124
*DP11C40124
*DN11C00124
THERMOSTAT
RH
24 – Volt Hot
(Heat XFMR)
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
Selection of GAS/ELEC
switch on thermostat
is not necessary
C
24 – Volt Common
Y
Full Stage Compressor
G
Fan
*BN11C00124
THERMOSTAT
RH
24 – Volt Hot
(Heat XFMR)
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
Thermostat Installer Setup
1-System Type-must be
set to 0
C
24 – Volt Common
Thermostat Installer Setup
15-Compressor Protection
must be set to 5
External Humidistat
(Optional)
Open on Humidity Rise
ID MODELS
TG(8/9)S
C
24 – Volt Common
R
24 – Volt Hot
W
Full Stage Heat
SINGLE STAGE PSC
FURNACE
G
Fan
SINGLE STAGE
PSC
FURNACE
Y/Y2
Full Stage Compressor
24VAC Humidifier
Relay
(Optional)
TGLS