METHOD 2: AUTOMATIC PROGRAMMING OF LIMIT POSITIONS

5

1. In case of setting the limit positions, the upper or lower limit position can be corrected.

2. Longer than 2 minutes pause between series of button clicks during programming will cause device to switch off from 

programming mode without saving any changes.

Automatic programming of limit positions should start from the upper limit position

9. Regulation limit positions

B. LOWER LIMIT POSITION:

REGULATION OF THE UPPER LIMIT POSITION:

REGULATION OF THE LOWER LIMIT POSITION:

Roller shutters will

make 2 short up/down

movements. Motor will

make several sounds.

Press

DOWN button.

We stop the motor

in the lower limit position.

Simultaneously

press and hold DOWN

and STOP buttons for

2 seconds to confirm

lower limit position.

Press and hold

UP button for 2 seconds.

When the roller shutter feels 

resistance, it will stop and the 

upper limit position will be set. 

Then the motor will move in 

the opposite direction.

When the roller shutters 

reaches the lower limit 

position, the motor will feel 

resistance stop and set the 

lower end position.

Simultaneously

press and hold UP and STOP

buttons for 5 seconds.

Motor will make

a sound. Roller shutter

will make short

up/down movements

Roller shutters will

make 2 short up/down

movements. Motor will

make several sounds.

The upper limit position has 

been changed.

The lower limit position 

has been changed.

We set the new

upper limit position.

Simultaneously press

and hold UP and STOP

buttons for 2 seconds

to confirm new upper

limit position.

Simultaneously press

and hold DOWN and STOP

buttons for 5 seconds.

Motor will make

a sound. Roller

shutter will make short

up/down movements.

Roller shutters will

make 2 short up/down

movements.Motor will

make several sounds.

We set the new

lower limit position.

Simultaneously press and hold

DOWN and STOP buttons for 

2 seconds to confirm new 

lower limit position.

The lower limit position 

has been set.

Limit positions 

have been set.

Summary of Contents for Smart Home 45 EM/S Series

Page 1: ...tacle detection Non compliance with the speci cation might cause risk for life or health and can determine proper work of the blind We strongly recommend to comply with the speci cation Installation o...

Page 2: ...used when placing motor in the tube During the adapter montage special attention must be paid not to damage the motor Motor and its control system should be kept out of children reach 2 PROGRAMMING B...

Page 3: ...slow blow fuse Creating electrical system using inadequate fuse may result in loosing rights under the provisions of warranty When connecting device to power source with cables with adequate cross sec...

Page 4: ...ING OF LIMIT POSITIONS USING A REMOTE CONTROL A UPPER LIMIT POSITION Turn on power supply or press microswitch approx 2 sec when power is on Motor will make a sound Roller shutter will make an up down...

Page 5: ...limit position will be set Then the motor will move in the opposite direction When the roller shutters reaches the lower limit position the motor will feel resistance stop and set the lower end posit...

Page 6: ...rd limit position has been set The third limit position has been removed Limit positions has been removed Press STOP button Press STOP button Motor will make a sound Roller shutters will make short up...

Page 7: ...ake a several short sounds Press and hold STOP button on the B remote control for 2 seconds 14 Deleting another transmitter 15 Deleting all transmitters Motor will make a sound Roller shutters will ma...

Page 8: ...s If the motor performs two short up down movements and make two sounds it means that the motor is in mode 2 The sensitivity of obstacle detection is reduced to 10 cm from the upper and lower limit po...

Reviews: