background image

13

Timer

With YoLink app, you can set up a  mer to turn on or/and off the outlet

Note

One  mer will run only once. You can set a new  mer a er the  mer has already run or once you 
cancel it
A er se ng up, the  mer is running at device without internet

Tap “        ” bu on

to enable or disable 
the  mer

* Choose ac on from “on”, 
“off”, or “on then off”

Tap to save the se ngs

Set the  mer dura on 

in Hours and Minutes

Summary of Contents for YS6704-UC

Page 1: ...In wall Outlet YS6704 UC Installa on User Guide Rev 1 1...

Page 2: ...Contents In the Box 1 Introduc on 2 Set Up 4 Installa on 6 Using the YoLink App 11 About YoLink Control 18 Maintenance 24 Speci ca ons 26 Troubleshoo ng 28 Warning 29 Customer Service Warranty 30...

Page 3: ...1 In the Box A In wall Outlet B 2 Cross Head Screw M3 C Slo ed Head Screw M3 2 D Quick Start Guide CONTROLLED CLASS 2 5VDC Max2 4A ALWAYS ON A C B D...

Page 4: ...party automa on apps such as IFTTT 2 WHITE HOT Live Wire Ground Wire Neutral Wire Moun ng Hole Moun ng Hole POWER Bu on Press once to turn on or o the outlet Outlet 1 Controlled Plug in your device an...

Page 5: ...ON Green Outlet is On Not on when the outlet is O Blinking Green Connec ng to Cloud Fast Blinking Green Establishing Connec on with YoLink System Slow Blinking Green Upda ng Irregular Blinking Green R...

Page 6: ...ogle Play Store Log in or create a new account if required Download and log in to YoLink app 1 Make sure your hub is connected to the internet green LED indicator is blinking blue LED indicator is alw...

Page 7: ...s The green LED indicates the device is online and ready to use Tap bu on then scan QR Code on the device 5 Turn on power a er installa on Tap bu on to add devices 1 2 If the outlet is powering on pre...

Page 8: ...ty prac ces can result in injury or death All wiring connec ons must be made a er the power is turned o to avoid personal injury and or damage to the outlet In wall Outlet is designed and intended for...

Page 9: ...ve circuits within the switch box Unscrew and remove the outlet plate then use a voltage tester to con rm the circuit is dead Exis ng wall outlet to be replaced or new box with wiring ready neutral wi...

Page 10: ...only be working with the wires connected directly to the outlet Compare your new outlet with the one you re replacing to nd the corresponding loca ons for the electrical screw connectors If you must r...

Page 11: ...nec ng the wire to the terminal ensure there is about 1 2 inch of bare wire visible strip o insula on as needed Insert the wire into the terminal Tighten the screw terminal Gently tug on the wire to e...

Page 12: ...Snap on the outlet plate and screw it turn on the power at the circuit breaker Snap on the plate and screw it Turn on the power Secure the outlet to the box with two screws Push outlet and wiring int...

Page 13: ...to page 13 Connec on status of outlet and Hub Details Tap to go to Details page refer to page 12 Device name Edit name on Details page Real me status Turned on or turned o Schedule Create on o schedul...

Page 14: ...page 24 Device status Turned on or turned o Tap to delete the device from your YoLink account Add remove from favorites Device type Choose a room for device Device EUI unique Device history Outlet tu...

Page 15: ...will run only once You can set a new mer a er the mer has already run or once you cancel it A er se ng up the mer is running at device without internet Tap bu on to enable or disable the mer Choose ac...

Page 16: ...in Automa on se ngs Automa on se ngs are saved in the cloud A er se ng up the schedule is running at device without internet 14 Tap to save the se ngs Tap bu on to enable or disable the schedule Click...

Page 17: ...scenes You can choose to either edit or delete each of them Tap bu on to enable or disable the scene Click to edit the scene Swipe le to edit or delete the scene Add remove from favorites Edit behavi...

Page 18: ...ave at least one ac on device or you cannot set a behavior Edit when Set a me range for the automa on always or during speci c days mes Tap to add an automa on Tap bu on to enable or disable the autom...

Page 19: ...the upper le corner to go to My Pro le Connect YoLink with third party voice assistants service to control or monitor the status of your devices through voice commands In wall Outlet is integrated wi...

Page 20: ...Examples of a controller are a Door Sensor or In wall Outlet while examples of a responder are another In wall Outlet or a YoLink Plug Mini To con gure your In wall as a controller Turn on the using P...

Page 21: ...n or In wall Ou Mini turn o the YoLink Plug when the outlet turns on Mini If you want to turn on or o the Mini when YoLink Plug the outlet turns o turn o the outlet verify the Status LED of In wall Ou...

Page 22: ...verify the Status LED of YoLink Plug Mini Refer to the YoLink displays blue Plug Mini manual for more informa on YS6604 UC_YoLink Plug Mini 20 Turn on the outlet verify the Status LED of In wall Outl...

Page 23: ...will remain turned on un l turned o using the POWER bu on or via the app More advanced sequences controlling mul ple outputs e g turn o plug are available via the YoLink app Opera on 21 When the outle...

Page 24: ...will stop blinking and return to the previous color outlet Green for turned on plug blue for turned on red for turned o At the YoLink Plug Mini responder press and hold the POWER bu on for 10 15 seco...

Page 25: ...seconds until the red light blinks quickly POWER Bu on Turn on the outlet verify the Status LED of In wall Outlet displays green 23 Hold the POWER button on the In wall Outlet Turned on for 10 15 seco...

Page 26: ...an update is available In Firmware if a new version is listed as available ready now click it to start the rmware update process You may use your device during the update as it is performed in the bac...

Page 27: ...e it to factory defaults A er the factory reset your device will remain in your Yolink account Hold the POWER bu on for 20 25 seconds un l the Status LED slowly blinks green irregularly Factory reset...

Page 28: ...Speci ca ons 26 Maximum Current 15A Input Output Voltage AC100 120V 60Hz Environment Temperature 14 F 104 F 10 C 40 C Humidity 10 90 non condensing USB Output 5V 2 4A MAX...

Page 29: ...ATE SIDE CONTROLLED CLASS 2 5VDC Max2 4A ALWAYS ON 1 34 34 0 1 69 43 0 2 62 66 5 4 15 105 5 1 30 33 0 FRONT 1 81 46 0 0 06 1 5 1 48 37 5 2 77 70 3 SIDE TOP 1 54 39 0 1 69 43 0 1 30 33 0 1 81 46 0 FACE...

Page 30: ...ce If outlet is out of range with Hub reloca ng the Hub may be required If outlet is not turned on turn on the device 2 Timer does not run Power outages before or during can prevent the mer from execu...

Page 31: ...evice only in clean environments Dusty or dirty environments may prevent the proper opera on of this device and will void the warranty Do not load more than 15A resis ve for the device Other loads 16A...

Page 32: ...oducts used in commercial applica ons This warranty does not apply to In wall Outlets that have been improperly installed modi ed put to a use other than designed or subjected to acts of God such as o...

Page 33: ...can be determined by turning the equipment o and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Connec...

Page 34: ...pplicable to only Mobile Con gura ons The antennas used for this transmi er must be installed to provide a separa on distance of at least 20 cm from all persons and must not be co located or opera ng...