background image

Recommended

1.     Branch pipe

2.     Main pipe approx. 1:100 Downward pitch away from the compressor

3.     Drain trap

4.     Shut-off valve

5.     Filter

6.     Regulator

7.     Oiler

8.     Coupling

9.     Air Hose (thick as poss)

10.   Air compressor

11.   Main pipe

 

Technical specifications

 

 

Brand : Toku
Safety standard : EN ISO 11148-5
Shank size (mm) : H^22 x 82
Piston (mm) : 54
Stroke (mm) : 45
Strokes per minute : 2450
RPM : 250
Energy (J/Stroke) : 44,7
Airconsumption (l/s) : 26
Weight (kg) : 17,4
Airconnection : PT 3/4"
Hosediameter (mm) : 19
Vibration level (m/s²) : 7
Noiselevel (dB(A)) : 99
mm A : 468
mm B : 340
Maximum Airpressure (Bar) : 6,3

Before taking into use

Read and understand the contents of this manual before installing, operating, repairing, maintaining, changing accessories this tool.

Only qualified and trained operators should install, adjust or use the tool.

Please fill some droplets of resin and acid free oil into the air inlet and let the tool run free for a couple of seconds. (E.g. Red Rooster air tool oil: Order

no. Atlub)

Before connecting the hose to the tool please check, whether the hose and the quick coupler are clean. Do this by letting air run freely through hose and

quick coupler, It is absolutely necessary, that quick coupler and hose have a sufficient diameter. Please note, that the hose is never too big, but mostly too

small!

Air pressure at the inlet of the tool during running has to be at the maximum of 6.3 bar. When this pressure is exceeded, unnecessary wear and/or

damage will occur. At the pressure of below 5.5 bar power loss will occur and if the pressure is excessively low, also additional wear/damage will occur.

The quality of the compressed air must be good, which means clean, dry and this is best assured by means of an air filter. We advise the use of a

complete FRL (filter, regulator, lubricator) unit. The oiler has to be adjusted to approx. 3 to 6 droplets per minute. The air hose between oiler and tool

should never exceed a length of 6 to 8 meters.

In those cases, where it is possible, use of a centralized oiler is recommended by us. This system will allow use of less oil and assure a perfect lubrication.

When using a centralized oiler, oil consumption can be reduced by up to 80%.

 

 

Do not ignore safety precautions!

Reviews: