YOKOGAWA YHC4150X User Manual Download Page 34

 

©Yokogawa Corporation of America 
2 Dart Road, Newnan, GA 30265 
770-254-0400 

 

 IM 61A YHC1-E-A  

1st Edition: Feb. 2008  

Page 29 of 34 

     

APPENDIX 

 

PRODUCT SPECIFICATIONS 
 

BASE UNIT:

  10.375" L, 4.25” W – top , 4.375" W – middle, 1.875” D.  Handle: 2.50” W, 1.25"D  

                         ABS plastic case with shock absorbing boot, 1.7 lbs including batteries and boot

 

 

DISPLAY:

 128 x 128 pixel graphic display, 2.6” x 2.6” viewable area, backlight 

 

 

POWER:

 six (6) AA alkaline batteries, six (6) or 100 – 240 Vac universal power adapter (P/N Z9B000007) connected 

to the YHC via the Communication / AC Adapter Dongle.  
  

Note:  Use  only  approved  AA  alkaline  batteries  in  Intrinsically  Safe  units.    DO  NOT  USE  unapproved 
AA  alkaline  batteries  or  other  battery  types  in  Intrinsically  Safe  units.    Do  not  use  the  Dongle  or  AC 
Adapter with Intrinsically Safe units in a potentially hazardous environment. See the “Hazardous Area 
Use”  section  of  this  manual,  the  specifications  below  and  the  Intrinsic  Safety  Control  Drawing  in  the 
Appendix of this manual for more information. 

 

BATTERY LIFE (Approximate):

   60 hours using AA alkaline batteries without backlight 

 

 

 

27 hours using AA alkaline batteries with backlight

 

 

 

 

 

TEMPERATURE SPECIFICATIONS: 

Storage:       -40° F to 140° F  (-40° C to 60° C) 
Operating:    23° F to 122° F   (-5° C to 50° C) 
  

CONNECTIONS:

  Standard banana jacks (¾” center) for HART communications 

   

 

           Communication / AC adapter connector for Dongle connection: AC power adapter and serial cable  

                                 (to PC port) connects to Dongle; Dongle connects to YHC. 
 

APPROVALS: YHC 4150X 
 

   

 

ATEX Intrinsically Safe              II 1 G; EEx ia IIC T4 

 

 

 

c

UL

us

  Listed 

 

   Intrinsically Safe, Exia  

 

 

   Class I, Div. 1 Groups A, B, C, D:  T4 

 

 

   -5º C < Ta < +50º C 

 

 

Entity parameters: 

   Li = 0, Ci = 0

 

  

 

  
                                                                           

 

 

 

 

 

 

Approved Batteries for ATEX/I.S.: (6) AA alkaline Duracell PC1500 

 

 

 

 

 

 

(6) AA alkaline Duracell  MN1500 

 

 

 

 

 

 

(6) AA alkaline Varta 4906 

                                                                         

 

MEMORY

 – separate, dedicated, non-volatile flash memory for YHC firmware, DOFs, and Configurations 

DOF Memory:

  560 HART devices (based on average DOF size) 

Configuration Memory:

 

 

200 HART devices (based on average configuration size)

 

 

AUTO SHUT-OFF

 - occurs after user-selected period of keypad inactivity or can be disabled (both YHC and backlight 

auto shut off are user selectable). 

 
DIAGNOSTICS

 – YHC self-tests upon power up.  Advisories are posted on the display. 

 

CE compliance  

 

ε

Χ

Summary of Contents for YHC4150X

Page 1: ...Yokogawa YHC4150X Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com analyzers yokogawa yhc4150x series YHC4150X...

Page 2: ...Yokogawa Corporation of America 2 Dart Road Newnan GA 30265 770 254 0400 IM 61A YHC1 E A 2nd Edition June 2010 Users Manual YHC 4150X HART Communicator Model YHC 4150X Series HART Communicator...

Page 3: ...merica directly by phone at 800 888 6400 or by e mail at info us yokogawa com Direct all assistance inquiries to the Meters and Instruments Group HART is a registered trademark of the HART Communicati...

Page 4: ...Configurations Settings 8 1 Users 8 2 Applications 8 3 Lockouts Lockout PV Prompt setting View Lockout Details 8 Lockout Code 9 Disable Lockout 9 Changing Lockout Code 9 4 Clock Timers 9 1 Clock Edit...

Page 5: ...us Message 21 Save Send Configuration Functions 21 DOF Memory Maintenance 22 Documenting HART Configurations with Yokogawa DMS Software 23 YHC 4150X Device Specific Generic HART Communication 23 Using...

Page 6: ...f approved YHCs and applicable restrictions DISPLAY OVERVIEW The display of the YHC is a 128 x 128 pixel graphic display with backlight Viewable area is 2 6 x 2 6 for 13 viewable message lines The dis...

Page 7: ...ween two separate functions as needed to facilitate data entry Soft key functions change depending on the operating mode Soft key definitions are displayed at the bottom of the LCD just above their re...

Page 8: ...e LCD display for ambient lighting and user preferences at any time and in any operating mode Pressing and holding this key cycles through all available contrast settings After adjusting Display Contr...

Page 9: ...ay are Soft Keys The specific functions of these keys change depending on the operating mode of the YHC Present definitions are displayed at the bottom of the YHC display Whenever possible the two Sof...

Page 10: ...g power When the YHC is used with the optional AC adapter P N Z9B000007 the battery circuit is bypassed and a wall plug icon replaces the battery icon on the display header For AC power use the AC ada...

Page 11: ...xt page of a list press and then the PgDn soft key To retreat to the prior page press and then PgUp PgUp and PgDn soft keys remain active until the Up or Down soft key is used or until is pressed agai...

Page 12: ...ion will be indicated when line three changes to Device 0 Online 2 2 Select Online Setup if properly connected HART device is setup for Multidrop loop or Burst Mode operation device address 0 The YHC...

Page 13: ...at a supervisor may wish to control The functions included are used to set up the YHC for normal use change online HART device configurations create offline HART device configurations update the insta...

Page 14: ...eys of the YHC will not work here Use the Increment Decrement and Next Soft Keys to input a lockout code value Alternatively you may use the green keys for Increment and Decrement functions When you a...

Page 15: ...date number of DOFs loaded with corresponding free memory space and number of HART configurations saved with corresponding free memory space 2 Battery shows present battery setting and optimizes the b...

Page 16: ...gin automatically If address 0 is not found the YHC automatically asks for direction select Multi soft key to start a multi drop poll from address 1 15 or select Retry soft key to try to find address...

Page 17: ...teries at once with all alkaline cells Do not mix alkaline batteries with each other or with other battery types Battery replacement is recommended when the Replace Batteries notice is posted on the d...

Page 18: ...ult from explosions Do not make any connection to the YHC s Dongle connector while in a hazardous area Use the connector Dongle only in non hazardous areas 2 HART Jacks Lead Set All YHC models are equ...

Page 19: ...ith new or mix batteries from different manufacturers DO NOT replace batteries while in explosive or hazardous atmospheres DO NOT use any battery type other than those listed on the Intrinsic Safe Con...

Page 20: ...vity HART Commands Three HART command types are used by the YHC to communicate with HART field devices First Universal Commands are primarily used to identify a field device by its model number and ta...

Page 21: ...ice is connected and attempts to establish HART communications this is the factory default Auto poll function When a device with address zero is found the YHC provides feedback to the user and starts...

Page 22: ...ds with address 15 All addresses on the loop will be displayed on the YHC s screen The address of interest can be selected from the list to launch HART communication with that device This Digital Poll...

Page 23: ...e Name or by stepping through all Devices one at a time Use the soft key controls to move through the list Pressing the key changes soft key definitions Down and Up to PgUp and PgDn To quickly advance...

Page 24: ...xisting configuration and includes only the edited parameters MVar Primary Cfg for multivariable devices Primary Variable configuration MVar Sub Config for multivariable devices Sub configuration seco...

Page 25: ...tructure for the connected device Consult the device manual for menu structure details YHC features two unique online features for added convenience to the user 1 Live HART connection monitor YHC disp...

Page 26: ...ility of the DOF needed by going to http dpcupdates 1911mptdofs com past aspx Sort the list by clicking on any column header For download instructions see the DOF Firmware Download Site section of thi...

Page 27: ...ght indicates that only 20 of DOF memory is free This indicates fragmentation To optimize DOF flash memory it is necessary to delete all DOFs and then reload them all in one session Connect the YHC to...

Page 28: ...with any HART device using Universal and Common Practice commands to poll configure and maintain HART devices Specific functions supported include most polling tagging device configuration and trim op...

Page 29: ...nder Subscriber Options Firmware updates are free of charge DOFs are available by subscription A list of currently available DOF s for HART device communication can be viewed at the http dpcupdates 19...

Page 30: ...ications and then Port to select COM port C Dongle and RS 232 Cable are connected to the YHC and the unit is turned on Note HART communication cannot occur while communicating using the RS 232 connect...

Page 31: ...ownload page for bulk downloads Select individual files for downloading from a list of downloadable files including DPC Manager Utility YHC Firmware and DOF s by locating the file name of interest wit...

Page 32: ...ettings in the toolbar and select Advance Settings To report any difficulties with downloading operations please contact Yokogawa at 770 254 0400 or Info us yokogawa com 8 Use the browser button to na...

Page 33: ...ll be provided by the Yokogawa Repair Department when you call fax or e mail your information An RA number must accompany all incoming packages to insure proper tracking processing and repair work To...

Page 34: ...ERY LIFE Approximate 60 hours using AA alkaline batteries without backlight 27 hours using AA alkaline batteries with backlight TEMPERATURE SPECIFICATIONS Storage 40 F to 140 F 40 C to 60 C Operating...

Page 35: ...ACCESSORIES LIST 4150 7R Protective red boot provides degree of protection against drop related damage slip on A900529 00014 HART Test Lead Kit included w YHC standard banana plugs mini grabbers 250...

Page 36: ...Yokogawa Corporation of America 2 Dart Road Newnan GA 30265 770 254 0400 IM 61A YHC1 E A 1st Edition Feb 2008 Page 31 of 34 Intrinsic Safety Control Drawing...

Page 37: ...als Model YHC 4150X series Certifying Agency UL International DEMKO A S Testing Certification 0539 P O Box 514 Lyskaer 8 DK 2730 Herlev Denmark This Declaration is based on Compliance with the followi...

Page 38: ...Damping Value Units Analog Alarm Analog Trim Menu 4mA Analog Trim 20mA Analog Trim DAC Trim Loop Test Scaled DAC Trim Revisions HART Revision Device Revision Software Revision Final Assbly Number Basi...

Page 39: ...ent Material Flange Type Remote Seal Isolator Material Flange Size Number of Remote Universal Revision Transmitter Revision Software Tag Date Descriptor Message ASC Model Ext SW Mode Revisions Const M...

Reviews: