YOKOGAWA YHC4150X User Manual Download Page 29

 

©Yokogawa Corporation of America 
2 Dart Road, Newnan, GA 30265 
770-254-0400 

 

 IM 61A YHC1-E-A  

1st Edition: Feb. 2008  

Page 24 of 34 

In general, the Generic HART mode operates similarly to its device specific DOF counterpart (see HART 
Communication section of this manual for more details).  However, the YHC does not display Device Specific 
related communication menus or options when in the Generic communication mode. For example, the Zero and 
Sensor trim menu options (normally executed by Device Specific commands) are not displayed for pressure 
transmitters without DOF support.  Please see the 

Download Site 

section of this manual for information on 

downloading the latest Device Specific DOF files to your YHC. 

 

 

Updating the YHC 4150X Firmware and DOFs 

 

Overview 

Firmware upgrades and new DOFs can be downloaded via the Internet in either of two ways. The first way is 
to use the DPC Manager utility (shipped with each YHC or downloaded from the DOF Download Site) on a 
PC with Internet access to download files from the DOF Download Site automatically and then update the 
YHC.  The second way is to use the DOF Download Site to download the needed files to the host PC and 
then use the DPC Manager utility to coordinate the update of the YHC. The Download Site enables users to 
stay current as new DOF’s or revisions of existing ones are posted.  Automatic email notices of new DOF 
postings are sent to all users who have logged on to the Download Site and registered their email address 
under “Subscriber Options.”  Firmware updates are free of charge. DOFs are available by subscription. 
 
A list of currently available DOF’s for HART device communication can be viewed at the 

http://dpcupdates.1911mptdofs.com/past.aspx

 

  
 

Who has access to the Download Site? 

All YHC customers can purchase a subscription to the DOF Download Site.  These customers may 
download any published file from the site to their host PC upon entry of the proper authenticating 
codes (User Name and Password shipped with each unit). Contact Yokogawa at 770.254.0400 or 

[email protected]

 for more information and to purchase subscriptions.   

PC Requirements for Download Operations  

Yokogawa recommends IBM compatible Pentium I PCs or higher for download operations.  The PC 
should have an available RS-232 port, minimum modem speed of 28K and access to Internet service. 
USB ports can be used with USB to serial adapters as well. The RS-232 port must not be shared with 
other software applications during update operations. 

Preparing the YHC  

All YHC models come ready to connect to an IBM compatible PC. Connect the supplied 
Communication / AC Adapter Dongle (P/N Z4150-10A) to the YHC. Connect the Dongle to the PC 
using the supplied six-foot male DB-9 to female DB-9 cable (P/N ZA90047-00052).  Similar cables 
are acceptable.  Provide power to the Dongle using the supplied AC Adapter (P/N Z9B000007). The 
YHC is ready for download operations. 

 

Warning:  To avoid damage to a PC serial port, do not connect the YHC’s HART leads to an AC powered 
HART device while the YHC is on AC power and a serial cable is connected to a PC. Yokogawa 
recommends disconnecting the HART leads from the YHC prior to any communication activity. 

 
 
 

Summary of Contents for YHC4150X

Page 1: ...Yokogawa YHC4150X Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com analyzers yokogawa yhc4150x series YHC4150X...

Page 2: ...Yokogawa Corporation of America 2 Dart Road Newnan GA 30265 770 254 0400 IM 61A YHC1 E A 2nd Edition June 2010 Users Manual YHC 4150X HART Communicator Model YHC 4150X Series HART Communicator...

Page 3: ...merica directly by phone at 800 888 6400 or by e mail at info us yokogawa com Direct all assistance inquiries to the Meters and Instruments Group HART is a registered trademark of the HART Communicati...

Page 4: ...Configurations Settings 8 1 Users 8 2 Applications 8 3 Lockouts Lockout PV Prompt setting View Lockout Details 8 Lockout Code 9 Disable Lockout 9 Changing Lockout Code 9 4 Clock Timers 9 1 Clock Edit...

Page 5: ...us Message 21 Save Send Configuration Functions 21 DOF Memory Maintenance 22 Documenting HART Configurations with Yokogawa DMS Software 23 YHC 4150X Device Specific Generic HART Communication 23 Using...

Page 6: ...f approved YHCs and applicable restrictions DISPLAY OVERVIEW The display of the YHC is a 128 x 128 pixel graphic display with backlight Viewable area is 2 6 x 2 6 for 13 viewable message lines The dis...

Page 7: ...ween two separate functions as needed to facilitate data entry Soft key functions change depending on the operating mode Soft key definitions are displayed at the bottom of the LCD just above their re...

Page 8: ...e LCD display for ambient lighting and user preferences at any time and in any operating mode Pressing and holding this key cycles through all available contrast settings After adjusting Display Contr...

Page 9: ...ay are Soft Keys The specific functions of these keys change depending on the operating mode of the YHC Present definitions are displayed at the bottom of the YHC display Whenever possible the two Sof...

Page 10: ...g power When the YHC is used with the optional AC adapter P N Z9B000007 the battery circuit is bypassed and a wall plug icon replaces the battery icon on the display header For AC power use the AC ada...

Page 11: ...xt page of a list press and then the PgDn soft key To retreat to the prior page press and then PgUp PgUp and PgDn soft keys remain active until the Up or Down soft key is used or until is pressed agai...

Page 12: ...ion will be indicated when line three changes to Device 0 Online 2 2 Select Online Setup if properly connected HART device is setup for Multidrop loop or Burst Mode operation device address 0 The YHC...

Page 13: ...at a supervisor may wish to control The functions included are used to set up the YHC for normal use change online HART device configurations create offline HART device configurations update the insta...

Page 14: ...eys of the YHC will not work here Use the Increment Decrement and Next Soft Keys to input a lockout code value Alternatively you may use the green keys for Increment and Decrement functions When you a...

Page 15: ...date number of DOFs loaded with corresponding free memory space and number of HART configurations saved with corresponding free memory space 2 Battery shows present battery setting and optimizes the b...

Page 16: ...gin automatically If address 0 is not found the YHC automatically asks for direction select Multi soft key to start a multi drop poll from address 1 15 or select Retry soft key to try to find address...

Page 17: ...teries at once with all alkaline cells Do not mix alkaline batteries with each other or with other battery types Battery replacement is recommended when the Replace Batteries notice is posted on the d...

Page 18: ...ult from explosions Do not make any connection to the YHC s Dongle connector while in a hazardous area Use the connector Dongle only in non hazardous areas 2 HART Jacks Lead Set All YHC models are equ...

Page 19: ...ith new or mix batteries from different manufacturers DO NOT replace batteries while in explosive or hazardous atmospheres DO NOT use any battery type other than those listed on the Intrinsic Safe Con...

Page 20: ...vity HART Commands Three HART command types are used by the YHC to communicate with HART field devices First Universal Commands are primarily used to identify a field device by its model number and ta...

Page 21: ...ice is connected and attempts to establish HART communications this is the factory default Auto poll function When a device with address zero is found the YHC provides feedback to the user and starts...

Page 22: ...ds with address 15 All addresses on the loop will be displayed on the YHC s screen The address of interest can be selected from the list to launch HART communication with that device This Digital Poll...

Page 23: ...e Name or by stepping through all Devices one at a time Use the soft key controls to move through the list Pressing the key changes soft key definitions Down and Up to PgUp and PgDn To quickly advance...

Page 24: ...xisting configuration and includes only the edited parameters MVar Primary Cfg for multivariable devices Primary Variable configuration MVar Sub Config for multivariable devices Sub configuration seco...

Page 25: ...tructure for the connected device Consult the device manual for menu structure details YHC features two unique online features for added convenience to the user 1 Live HART connection monitor YHC disp...

Page 26: ...ility of the DOF needed by going to http dpcupdates 1911mptdofs com past aspx Sort the list by clicking on any column header For download instructions see the DOF Firmware Download Site section of thi...

Page 27: ...ght indicates that only 20 of DOF memory is free This indicates fragmentation To optimize DOF flash memory it is necessary to delete all DOFs and then reload them all in one session Connect the YHC to...

Page 28: ...with any HART device using Universal and Common Practice commands to poll configure and maintain HART devices Specific functions supported include most polling tagging device configuration and trim op...

Page 29: ...nder Subscriber Options Firmware updates are free of charge DOFs are available by subscription A list of currently available DOF s for HART device communication can be viewed at the http dpcupdates 19...

Page 30: ...ications and then Port to select COM port C Dongle and RS 232 Cable are connected to the YHC and the unit is turned on Note HART communication cannot occur while communicating using the RS 232 connect...

Page 31: ...ownload page for bulk downloads Select individual files for downloading from a list of downloadable files including DPC Manager Utility YHC Firmware and DOF s by locating the file name of interest wit...

Page 32: ...ettings in the toolbar and select Advance Settings To report any difficulties with downloading operations please contact Yokogawa at 770 254 0400 or Info us yokogawa com 8 Use the browser button to na...

Page 33: ...ll be provided by the Yokogawa Repair Department when you call fax or e mail your information An RA number must accompany all incoming packages to insure proper tracking processing and repair work To...

Page 34: ...ERY LIFE Approximate 60 hours using AA alkaline batteries without backlight 27 hours using AA alkaline batteries with backlight TEMPERATURE SPECIFICATIONS Storage 40 F to 140 F 40 C to 60 C Operating...

Page 35: ...ACCESSORIES LIST 4150 7R Protective red boot provides degree of protection against drop related damage slip on A900529 00014 HART Test Lead Kit included w YHC standard banana plugs mini grabbers 250...

Page 36: ...Yokogawa Corporation of America 2 Dart Road Newnan GA 30265 770 254 0400 IM 61A YHC1 E A 1st Edition Feb 2008 Page 31 of 34 Intrinsic Safety Control Drawing...

Page 37: ...als Model YHC 4150X series Certifying Agency UL International DEMKO A S Testing Certification 0539 P O Box 514 Lyskaer 8 DK 2730 Herlev Denmark This Declaration is based on Compliance with the followi...

Page 38: ...Damping Value Units Analog Alarm Analog Trim Menu 4mA Analog Trim 20mA Analog Trim DAC Trim Loop Test Scaled DAC Trim Revisions HART Revision Device Revision Software Revision Final Assbly Number Basi...

Page 39: ...ent Material Flange Type Remote Seal Isolator Material Flange Size Number of Remote Universal Revision Transmitter Revision Software Tag Date Descriptor Message ASC Model Ext SW Mode Revisions Const M...

Reviews: