The editing function allows review of all HART parameters in a config- 
uration and modification of editable parameters.  The edit function can be  
locked out if desired (see the 

Lockout

 section of this manual for more 

information). To view detailed information of a stored configuration, move  
the cursor to the desired tag number and press the Select soft key.  The  
Config Detail screen (see example at right) provides information to help  
the user confirm the identity, origin, and save date/time of the configuration.  
Pressing Select again opens the configuration for review or offline editing.  
 
New configurations saved are added to the bottom of the List / Edit Config  
list.  If multiple entries for one device are shown, the most recently saved  
configuration is always shown at the bottom. 
 
Entries in the List / Edit Config list may have been saved or created from  
various sources. Possible sources include the save command from a  
connected HART device, created in the YHC using the 

Create Configs

 function, copied from another 

configuration and renamed, or created by editing an existing file.  The YHC will also list configurations 
downloaded from the separately available Device Management System software from Yokogawa. Please 
contact us for more information. Tag numbers, date / time of save, type of configuration stored, and other 
information are displayed under 

List/Edit Configs

. Configuration types are: 

 
Complete Config   = saved from connected device in Online mode, or a 
                                   complete config that was downloaded from DMS 
Default Config 

= created by YHC in Offline mode, or created in DMS 

                                    and downloaded to YHC 
Edit Vars Only 

= created by editing an existing configuration and includes only the edited parameters  

MVar Primary Cfg  = for multivariable devices – Primary Variable configuration 
MVar Sub Config  = for multivariable devices – Sub-configuration (secondary, tertiary, fourth, etc  
                                    variables) 

3  Create Configs:   

The 

Create Configs

 function allows the user to configure a HART device file in Offline Mode for sending 

to the intended device later when connected in the Online Mode.  Use the soft key controls to move through 
the list and select the device model number required.  The menus prompt the user to make the necessary 
configuration selections, tag the file for later retrieval and use, and edit configuration lines as required.  This 
function can be locked out.  See the Lockout Section of this manual for more information. 
 

4  Delete All Configs:

 

The 

Delete All Configs 

function clears 

all

 configurations from memory (including active and hidden 

configs).  When this menu option is selected, the YHC will ask “Delete ALL Configs…  ARE YOU 
SURE???”  Select 

Yes

 to clear 

all

 stored configurations from memory. 

 

Delete Individual Configs / Clearing Configuration Memory: 

Individual stored Configurations may be deleted with YHC 

Del

 soft key 

function (see example at right).  When this menu option is selected, the YHC 
will ask “Delete CURRENT Config…  ARE YOU SURE???”  Select 

Yes

 to 

clear only the selected configuration from memory.   
 
The 

Del

 key only hides the record from the YHC screen; it does not clear 

memory space.  This function can be locked out.  See the Lockout Section of 
this manual for more information. 
 

 
Online Setup Mode 

Offline List / Edit  

Configs Detail Screen

Offline                

          # 

 

 

List/Edit Configs 
 Tag:   PT-105A  
      
    Device ID 1365 
    PV:  Pressure 

 

    Yokogawa 
    EJX 
    Complete Config 
    Uses DOF 37510103 
    51 Variables 
    12/18/07  4:58 PM  

 

 

Copy       Del         Select     Back

Offline List / Edit  

Configs Detail Screen

Offline                

          # 

 

 

List/Edit Configs 
 Tag:   PT-105A  
      
    Device ID 1365 
    PV:  Pressure 

 

    Yokogawa 
    EJX 
    Complete Config 
    Uses DOF 37510103 
    51 Variables 
    12/18/07  4:58 PM  

 

 

Copy       Del         Select     Back

Summary of Contents for YHC 4150 Series

Page 1: ...IM 61A YHC1 E A 3rd Edition May 2008 Users Manual YHC 4150X HART Communicator Model YHC 4150X Series HART Communicator...

Page 2: ...Representatives and their contact information visit our web site at www yokogawa com HART is a registered trademark of the HART Communication Foundation Important information on the product is contai...

Page 3: ...2 Applications 8 3 Lockouts Lockout PV Prompt setting View Lockout Details 8 Lockout Code 9 Disable Lockout 9 Changing Lockout Code 9 4 Clock Timers 9 1 Clock Edit 9 2 Backlight off timer 10 3 Off Tim...

Page 4: ...Functions 21 DOF Memory Maintenance 22 Documenting HART Configurations with Yokogawa DMS Software 23 YHC 4150X Device Specific Generic HART Communication 23 Using Generic HART Communications 23 Updati...

Page 5: ...ctions DISPLAY OVERVIEW The display of the YHC is a 128 x 128 pixel graphic display with backlight Viewable area is 2 6 x 2 6 for 13 viewable message lines The display provides three types of informat...

Page 6: ...to facilitate data entry Soft key functions change depending on the operating mode Soft key definitions are displayed at the bottom of the LCD just above their respective gray soft keys The left hand...

Page 7: ...d user preferences at any time and in any operating mode Pressing and holding this key cycles through all available contrast settings After adjusting Display Contrast wait at least five 5 seconds befo...

Page 8: ...ns of these keys change depending on the operating mode of the YHC Present definitions are displayed at the bottom of the YHC display Whenever possible the two Soft Keys on left are used for navigatio...

Page 9: ...optional AC adapter P N Z9B000007 the battery circuit is bypassed and a wall plug icon replaces the battery icon on the display header For AC power use the AC adapter is connected to the Communicatio...

Page 10: ...PgDn soft key To retreat to the prior page press and then PgUp PgUp and PgDn soft keys remain active until the Up or Down soft key is used or until is pressed again 4 Numbered HART menus All HART disp...

Page 11: ...changes to Device 0 Online 2 2 Select Online Setup if properly connected HART device is setup for Multidrop loop or Burst Mode operation device address 0 The YHC will respond with a statement and the...

Page 12: ...nline HART device configurations create offline HART device configurations update the installed DOFs list HART device profiles or to update the YHC s operating firmware For example locking out the Con...

Page 13: ...t and Next Soft Keys to input a lockout code value Alternatively you may use the green keys for Increment and Decrement functions When you are satisfied with the lockout code value press Store IMPORTA...

Page 14: ...sponding free memory space and number of HART configurations saved with corresponding free memory space 2 Battery shows present battery setting and optimizes the battery life indicator for the battery...

Page 15: ...found the YHC automatically asks for direction select Multi soft key to start a multi drop poll from address 1 15 or select Retry soft key to try to find address 0 again for more details see the HART...

Page 16: ...s Do not mix alkaline batteries with each other or with other battery types Battery replacement is recommended when the Replace Batteries notice is posted on the display however the YHC will function...

Page 17: ...onnection to the YHC s Dongle connector while in a hazardous area Use the connector Dongle only in non hazardous areas 2 HART Jacks Lead Set All YHC models are equipped with a standard size banana jac...

Page 18: ...nt manufacturers DO NOT replace batteries while in explosive or hazardous atmospheres DO NOT use any battery type other than those listed on the Intrinsic Safe Control Document found in the Appendix o...

Page 19: ...Three HART command types are used by the YHC to communicate with HART field devices First Universal Commands are primarily used to identify a field device by its model number and tag number and to rea...

Page 20: ...blish HART communications this is the factory default Auto poll function When a device with address zero is found the YHC provides feedback to the user and starts the initial HART display for the conn...

Page 21: ...he loop will be displayed on the YHC s screen The address of interest can be selected from the list to launch HART communication with that device This Digital Poll is for one power cycle only and can...

Page 22: ...ices one at a time Use the soft key controls to move through the list Pressing the key changes soft key definitions Down and Up to PgUp and PgDn To quickly advance to the next page of a list press the...

Page 23: ...ly the edited parameters MVar Primary Cfg for multivariable devices Primary Variable configuration MVar Sub Config for multivariable devices Sub configuration secondary tertiary fourth etc variables 3...

Page 24: ...sult the device manual for menu structure details YHC features two unique online features for added convenience to the user 1 Live HART connection monitor YHC display lets you know from the Main navig...

Page 25: ...DOFs link at http fibu yokogawa usa com yhc4150 html Sort the list by clicking on any column header For download instructions see the DOF Firmware Download Site section of this manual 2 The connected...

Page 26: ...ory is free This indicates fragmentation To optimize DOF flash memory it is necessary to delete all DOFs and then reload them all in one session Connect the YHC to a host PC that has DPC Manager insta...

Page 27: ...using Universal and Common Practice commands to poll configure and maintain HART devices Specific functions supported include most polling tagging device configuration and trim operations for analog...

Page 28: ...ble by subscription A list of currently available DOF s for HART device communication can be viewed at the http fibu yokogawa usa com yhc4150 html Click on the Available DOFs link and sort the list by...

Page 29: ...port C Dongle and RS 232 Cable are connected to the YHC and the unit is turned on Note HART communication cannot occur while communicating using the RS 232 connection D The AC power adapter is connect...

Page 30: ...individual files for downloading from a list of downloadable files including DPC Manager Utility YHC Firmware and DOF s by locating the file name of interest with the PC mouse and clicking on the cor...

Page 31: ...Advance Settings To report any difficulties with downloading operations please contact a Yokogawa Office Representative or Agent 8 Use the browser button to navigate to the location of the DOF files...

Page 32: ...ly marked on the package being shipped back the unit will be returned at the shipper s expense This number will be provided by the Yokogawa Repair Department when you call fax or e mail your informati...

Page 33: ...A alkaline batteries without backlight 27 hours using AA alkaline batteries with backlight TEMPERATURE SPECIFICATIONS Storage 40 F to 140 F 40 C to 60 C Operating 23 F to 122 F 5 C to 50 C CONNECTIONS...

Page 34: ...YHC ACCESSORIES LIST Z4150 7G Protective green boot provides degree of protection against drop related damage slip on A900529 00014 HART Test Lead Kit included w YHC standard banana plugs mini grabbe...

Page 35: ...IM 61A YHC1 E A 3rd Edition May 2008 Page 31 of 34 Intrinsic Safety Control Drawing...

Page 36: ...Agency UL International DEMKO A S Testing Certification 0539 P O Box 514 Lyskaer 8 DK 2730 Herlev Denmark This Declaration is based on Compliance with the following Standards Regarding Hazardous Envi...

Page 37: ...og Trim Menu 4mA Analog Trim 20mA Analog Trim DAC Trim Loop Test Scaled DAC Trim Revisions HART Revision Device Revision Software Revision Final Assbly Number Basic Info Tag Date Descriptor Message Pr...

Page 38: ...Isolator Material Flange Size Number of Remote Universal Revision Transmitter Revision Software Tag Date Descriptor Message ASC Model Ext SW Mode Revisions Const Mats Device ID Polling Address Request...

Reviews: