2.3 Standard Specifications
Span Limits:
Refer to Table 2.1.
Span is continuously adjustable within range
limits.
Range Limits *:
Refer to Table 2.1.
*: when lower range-value is other than zero,
optional kit for elevated-zero or suppressed-
zero ranges is installed.
Overpressure Limits:
Refer to Table 2.1.
Output Signal:
Refer to Table 2.1.
Accuracy (includes linearity, hysteresis and
repeatability):
±0.5 % of span.
Repeatability:
0.1 % of span.
Dead Band:
0.05 % of span.
Air Supply Pressure:
140 kPa, 1.4 kgf/cm
2
or bar, or 20 psi.
Air Consumption:
0.5 m
3
/h at 0 °C, 101.3 kPa {1.033 kgf/cm
2
}
absolute (0.3 scfm).
Ambient Operating Temperature Range:
-40 to 120 °C (-40 to 250 °F).
Process Temperature Limits:
-40 and 120 °C (-40 and 250 °F) at capsule.
Mounting:
Bracket for nominal 50 mm (2 inches) horizontal or
vertical pipe.
Air Connection:
Tapped for JIS R1/4 or 1/4 NPT, whichever
specified.
Process Connections:
JIS Rc1/2, Rc1/4, 1/2 NPT, or 1/4 NPT female,
whichever specified.
Wetted Parts Material:
Process Connection Block: Forged JIS SUS 316
stainless steel.
Bellows Capsule: SUS 316L stainless steel.
Capsule Gaskets: Silicone elastomer.
Body Material:
Forged SUS 316 stainless steel. Not wetted by
process.
Connection Hardware:
JIS SCM435 chrome-molybdenum steel cap
screws and nuts through body and process
connection block.
Cover:
Cast aluminum, finished with gray polyurethane
paint. Gasketed for National Electrical
Manufacturers Association (NEMA) (USA) Type 3
weatherproof service.
Approximate Weight:
5.3 kg (12 lb).
Table 2.1 Span, Range and Overpressure Limits.
Capsule
–
M-calibration
P-calibration
bar-calibration
A
Span Limits
0.07 to 0.55 MPa
0.7 to 5.6 kgf/cm
2
10 to 80 psi
0.7 to 5.5 bar
Range Limits
-0.1 to 0.6 MPa
-1 to 6 kgf/cm
2
-50 to 90 psi
-1 to 6 bar
O. P. Limits
0.7 MPa
7 kgf/cm
2
100 psi
7 bar
B
Span Limits
0.14 to 1.4 MPa
1.4 to 14 kgf/cm
2
20 to 200 psi
1.4 to 14 bar
Range Limits
-0.1 to 2.4 MPa
-1 to 24 kgf/cm
2
-15 to 350 psi
-1 to 24 bar
O. P. Limits
3.5 MPa
35 kgf/cm
2
500 psi
35 bar
C
Span Limits
0.28 to 2.7 MPa
2.8 to 28 kgf/cm
2
40 to 400 psi
2.8 to 27 bar
Range Limits
-0.1 to 5.1 MPa
-1 to 52 kgf/cm
2
-15 to 750 psi
-1 to 51 bar
O. P. Limits
7 MPa
70 kgf/cm
2
1000 psi
70 bar
D
Span Limits
0.7 to 6.8 MPa
7 to 70 kgf/cm
2
100 to 1000 psi
7 to 68 bar
Range Limits
-0.1 to 10 MPa
-1 to 105 kgf/cm
2
-15 to 1500 psi
-1 to 100 bar
O. P. Limits
14 MPa
140 kgf/cm
2
2000 psi
140 bar
E
Span Limits
1.4 to 13.7 MPa
14 to 140 kgf/cm
2
200 to 2000 psi
14 to 137 bar
Range Limits
-0.1 to 20 MPa
-1 to 210 kgf/cm
2
-15 to 3000 psi
-1 to 200 bar
O. P. Limits
28 MPa
280 kgf/cm
2
4000 psi
280 bar
Output Signal
20 to 100 kPa
0.2 to 1.0 kgf/cm
2
3 to 15 psi
0.2 to 1.0 bar
Option Code
Standard
Specifications
CAL-M
CAL-E
CAL-B