YOKOGAWA VJQ8 Instruction Manual Download Page 6

6

All Rights Reserved. Copyright © 1999, Yokogawa M&C Corporation

IM 77J01Q08-01E

11.LIST OF PARAMETERS

No.

Item

  

Display

   

Remark

  

No.

       

Item

      

Display

Remark

01

  

Model

                 

MODEL

02

  

Tag no.

           

TAG NO

03

  

Self-check result

           

SELF CHK

Display items

  A

  

Display1

           

DISPLAY1

   

B

Display2

           

DISPLAY2

A01

  Input value

                                        INPUT1

         *1

         B01

Input value

                                        INPUT1

A05     Output value 1

                                        OUTPUT1

         B05

Output value 1

                  OUTPUT1

A06     Output value 2

                                        OUTPUT2

         B06

Output value 2

                  OUTPUT2

A07     Alarm-1 status

                                        ALM1 STATUS

         B07

Alarm-1 status

                   ALM1 STATUS

A08     Alarm-2 status

                                        ALM2 STATUS

         B08

Alarm-2 status

                   ALM2 STATUS

A31     Integrating counter 1

                  COUNTER1

         B31

Integrating counter 1

                   COUNTER1

A32     Integrating counter 2

                  COUNTER2

         B32

Integrating counter 2

                   COUNTER2

A33     Integrating counter 3

                  COUNTER3

         B33

Integrating counter 3

                   COUNTER3

A34     Integrating counter 4

                  COUNTER4

         B34

Integrating counter 4

                   COUNTER4

A54     Status

                                        STATUS

         *2

         B60

Self-check result

                   SELF CHK

A56     Rev. no                                                            REV NO                                         *1: Instantaneous frequency is displayed evenif conversion mode is pulse integration.

A58     MENU REV

                                        MENU REV

         *2: The Status is displayed for service personnel to see history records.

A60     Self-check result

                                        SELF CHK

Setting items

  D       Setting (I/O)

                                        SET(I/O)

           E

Setting (alarm output)

                   SET(ALM)

D01     Tag no. 1

                                        TAG NO.1

         E03

Alarm-1 setting

                   SET POINT1

D02     Tag no. 2

                                        TAG NO.2

         E04

Alarm-2 setting

                   SET POINT2

D03     Comment 1

                                        COMMENT1

         E05

Direction of alarm-1 action                    ALM1 ACTION

D04     Comment 2

                                        COMMENT2

         E06

Direction of alarm-2 action                    ALM2 ACTION

D10     Range unit

                                        UNIT

         E09

Alarm-1 hysteresis

                   HYSTERESIS1

D13     Low input cut point                                         LOW CUT

         E10

Alarm-2 hysteresis

                   HYSTERESIS2

D19     Conversion mode

                                        SELECT MODE

         E11

Alarm-1 ON delay setting                    ON DELAY1

D20     Sample mode

                                        SAMPLE MODE

         E12

Alarm-2 ON delay setting                    ON DELAY2

D21     Sample time

                                        SAMPLE TIME

         E13

Alarm-1 OFF delay setting                    OFF DELAY1

D22     Input low range

                                        INPUT1 L_RNG

         E14

Alarm-2 OFF delay setting                    OFF DELAY2

D23     Input high range

                                        INPUT1 H_RNG

         E15

Direction of alarm-1 relay action           RL1 ACTION

D38     Direction of output-1 action

                  OUT1 DR

         E16

Direction of alarm-2 relay action           RL2 ACTION

D39     Direction of output-2 action

                  OUT2 DR

         E60

Self-check result

                   SELF CHK

D50     Input filter

                                        INPUT FILTER

           F

Setting (communication)

                   SET(COM)

D60     Self-check result

                                        SELF CHK

         F01

Communication protocol

                   PROTOCOL

         F02

Address

                                         ADDRESS

                                                                                                                     F03

Baud rate

                                        BAUD RATE

                                                                                                                     F04

Parity

                                        PARITY

There are items not displayed depending on what output-2 is specified.

         F05

Data length                                         DATA LEN

                                                                                                                     F06

Stop bit

                                        STOP BIT

                                                                                                                     F07

Decimal point position of input              INPUT DEC PT

                                                                                                                     F60

Self-check result

                   SELF CHK

                                                     Adjusting items

                                                                                                         Test items

  P        Adjustment

                                         ADJUST1

           Q

Test

                                         TEST

P12      0% adjustment of output-1

                   OUT1 0%

         Q02

Forced output-1

                   OUT1 TEST

P13      100% adjustment of output-1

                   OUT1 100%

         Q03

Forced output-2

                   OUT2 TEST

P14      0% adjustment of output-2

                   OUT2 0%

         Q04

Forced output (alarm)

                   ALM1 TEST

P15      100% adjustment of output-2

                   OUT2 100%

         Q05

Forced output (alarm)

                   ALM2 TEST

P60      Self-check result

                                         SELF CHK

         Q60

Self-check result

                   SELF CHK

12.MAINTENANCE

The product starts running immediately when the power is turned on;
however, it needs 10 to 15 minutes of warm-up before it meets the
specified performance.
For cleaning the instrument, use a soft and dry cloth.

12.1 Calibration Apparatus

A pulse generator (Yokogawa FG300 or the equivalent): 1

A volt meter (Yokogawa 7562 or the equivalent) : 1

A counter (Hewllet-Packard Japan 5334B or the equivalent): 1

A precision resistor (250

 ±0.01% 1W): 1

12.2 Calibration Procedure

Connect the instruments as shown in Fig.12.1.
Produce input signals equivalent to 0, 25, 50, 75 and 100% of the in-
put span from the pulse generator to the converter.  Then, check that
the converter's output signal shows voltages corresponding to 0, 25,
50, 75, and 100% of the input span within the rated accuracy range.
If the output signal is out of the rated accuracy range, adjust the out-
put signal level using the Handy Terminal (JHT200).  For adjust-
ment, refer to Instruction Manual for VJ77 Parameters Setting Tools
(IM 77J01J77-01) or for Handy Terminal (IM JF82-01).

10

11

3

2

1

4

5

6

7

8

9

Input

Output-2

Output-1

Power supply

9

7

4

3

+

-

Pulse

Generator

R

+

-

5

2

Voltmeter

Voltmeter

R

R:For current output using 250 

 

   precision resistor

R:For current output using 250 

 

   precision resistor

+

-

11

10

8

L+

N-

GND

Fig. 12.1