Standard Specifications 

IM 01G05B02-01E 1st Edition 

Accessories (for ultrasonic flowmeter US300PM) 

Model 

Description 

USPA301 

Wall thickness probe for general temperature 

(

–20 to +60°C / –4 to +140°F) 

USPA302 

Wall thickness probe for high temperature 

(0 to +200°C / 32 to 392°F) 

USPA311 

Power supply adapter (100 to 240 V AC input) 

USPA321 

AC cable (Japan) 

USPA322 

AC cable (USA) 

USPA323 

AC cable (Europe) 

USPA324 

AC cable (United Kingdom) 

USPA325 

AC cable (Australia) 

USPA326 

AC cable (South Africa) 

USPA331 

Battery set (6 V 4Ah) (*5) 

USPA341 

Transportation case (*5) 

 

*5: Always comes with US300PM. 

 

Accessories (others) 

Model 

Description 

USPA401 

RS232 cable (*6) 

USPA402 

RS232 adapter 9/25 (*6) 

USPA411 

Measuring tape (*7) 

 

*6: Included in data transfer software US300SA as standard. 
*7: Included in US300PM as standard. 

 

Accessories (for transducers US300PT) 

Model 

Description 

USPA001 

Fixing strap (10 m / 32 ft length) 

USPA002 

Fixing strap (20 m / 65 ft length) 

USPA011 

Fixing clips 

(medium type, for pipe size 40 to 100 mm / 1.5 
to 4 in., set of two clips) 

USPA012 

Fixing clips 

(large type, for pipe size 100 to 6500 mm / 4 to 
255 in., set of two clips) 

USPA021 

Fixing bands 

(only for pipe size 25 to 50 mm / 1 to 2 in.) 

USPA032 

Fixing chains (set of two extensible chains) 

(2 m / 6.5 ft length, equal to 600 mm / 23 in. 
diameter) 

USPA033 

Repair set for fixing chains 

USPA034 

Retaining clips 

(set of two clips, used with fixing chains) 

USPA036 

Fixing chains (set of two extensible chains) 

(0.5m / 1.6 ft length, equal to 150mm / 5.9 in. 
diameter) 

USPA037 

Fixing chains (set of two extensible chains) 

(1 m / 3.2 ft length, equal to 300 mm / 11.8 in. 
diameter) 

USPA053 

Mounting fixture short ruler type (for 
transducers medium pipe size type, 
temperature range 

–30 to +200°C / –22 to 

+392°F, set of two blocks with 120 mm / 4.7 in. 
ruler) 

USPA054 

Mounting fixture standard type (for transducers 
medium pipe size type, temperature range 

–30 

to +200°C / 

–22 to +392°F, set of two blocks 

with 320 mm / 12.6 in. ruler) 

USPA055 

Mounting fixture magnetic general temperature 
type (for transducers medium pipe size type, 
temperature range 

–30 to +100°C / –22 to 

+212°F, set of two blocks with 320 mm / 12.6 
in. ruler) 

USPA057 

Mounting fixture standard type (for transducers 
large or very large pipe size type, temperature 
range 

–30 to +200°C / –22 to +392°F, set of 

two blocks with 320 mm / 12.6 in. ruler) 

USPA058 

Mounting fixture magnetic general temperature 
type (for transducers large or very large pipe 
size type, temperature range 

–30 to +100°C / –

22 to +212°F, set of two blocks with 320 mm / 
12.6 in. ruler) 

USPA073 

Additional magnets for mounting fixture 
magnetic general temperature type 

(for transducers medium pipe size type, 
temperature range 

–30 to +100°C / –22 to 

+212°F, set of two magnets) 

USPA075 

Additional magnets for mounting fixture 
magnetic general temperature type 

(for transducers large or very large pipe size 
type, temperature range 

–30 to +100°C / –22 to 

+212°F, set of two magnets) 

USPA081 

Ruler for mounting fixture 

(marked length 120 mm, equivalent to 4.7 in.) 

USPA082 

Ruler for mounting fixture 

(marked length 320 mm, equivalent to 12.6 in.) 

USPA091 

Acoustic couplant general temperature type 

(100 g, 

–30 to +130°C) (0.22 lb, –22 to +266°F) 

USPA092 

Acoustic couplant high temperature type 

(100 g, 

–30 to +200°C) (0.22 lb, –22 to +392°F) 

Summary of Contents for US300PM

Page 1: ...Scope of Delivery page 7 and the section 3 4 2 Rear Panel page 13 Change the figure of a nameplate to as below Addition to the section 2 3 General Precautions page 8 The power supply adapter and the AC cable are dedicated to US300PM Please do not use them with other devices Do not disassemble or remodel Addition to the chapter 4 Getting Started page 15 Attention The current outputs may temporarily...

Page 2: ...oldstart Pressing these two keys simultaneously and after acknowledging the display of main menu release i BRK first and then ii C This will initialize the instrument Most parameters and settings are reset to the factory default values The same procedure is required as above when the DELETE MEAS VAL display appears Addition to the section 5 6 Selection of the Sound Path Factor page 30 When you sel...

Page 3: ... When you select auto the setting for the sound path factor will be automatic Sound Path auto USER Changes to the section 11 6 Charging the Battery page 77 Change The chargeable NiCd batteries guarantee an operating time of approximately 14 hours to The chargeable NiCd batteries guarantee an operating time of approximately 10 hours at room temperature 20 C 68 F with full charge Addition to the sec...

Page 4: ...or two optional Range 4 to 20 mA Load resistance 0 to 500 Ω Note The current outputs may temporarily turn unstable during the switch on sequence and parameter display setting mode Take care of your process not to be affected by this behavior Frequency Output None standard or one optional Range 0 to 1 kHz Contact type Open collector 24 V 4 mA Binary Output None standard one or two optional Contact ...

Page 5: ...ng for printer Decimal point character Data delimiter Communication interface RS232 Communication port D sub 9 pin male Time Programmable Measurement Function Automatic start stop of the measurement without human operation using internal clock for specific systems Can be used with current output binary output data logging function and or communication function for recording the measurement Site Pa...

Page 6: ... and Built in battery set always come with US300PM Fixing Hardware Couplant etc Specified in the suffix code of US300FT transducers Model codes as accessories also available for separate additional orders listed later Power Supply Adapter and AC cable The power supply adapter and the AC cable are dedicated to US300PM Please do not use them with other devices Data Transfer Software General The soft...

Page 7: ...its of Measurement Volume flow Flow velocity Mass flow Totalizers Sound velocity Volume Mass m3 h m s g s m3 g m s m3 min inch s t h l kg m3 s kg h gal t l h kg min l min l s USgph USgpm USgps bbl d bbl h bbl m 1 gallon US 3 78 l 1 barrel 42 gallons 158 76 l ...

Page 8: ...sible IP67 Pipe Size Fluid Temperature 3 BG Medium General with 3 m 9 8 ft cable BH Medium High with 3 m 9 8 ft cable CG Large General with 4 4 m 14 4 ft cable CH Large High with 4 4 m 14 4 ft cable DG Very large General with 12 m 39 4 ft cable Mounting fixture 4 C Retaining clip type set of two clips S Standard type set of two blocks including ruler marked length 320 mm equivalent to 12 6 in M Ma...

Page 9: ...et of two extensible chains 1 m 3 2 ft length equal to 300 mm 11 8 in diameter USPA053 Mounting fixture short ruler type for transducers medium pipe size type temperature range 30 to 200 C 22 to 392 F set of two blocks with 120 mm 4 7 in ruler USPA054 Mounting fixture standard type for transducers medium pipe size type temperature range 30 to 200 C 22 to 392 F set of two blocks with 320 mm 12 6 in...

Page 10: ...on cable US300PC A Length Weight Transducer X m inch Y m inch X Y m inch Weight kg lb US300PT B 2 0 78 7 1 0 39 4 3 0 118 1 0 6 1 32 US300PT C 2 0 78 7 2 4 94 5 4 4 173 2 1 2 2 65 US300PT D 5 0 196 9 7 0 275 6 12 0 472 4 2 2 4 85 Length Weight Optional extension cable L m inch Weight kg lb US300PC A005 5 0 196 9 0 4 0 88 US300PC A010 10 0 393 7 0 6 1 32 US300PC A020 20 0 787 4 1 6 3 53 ...

Page 11: ...mperature 20 to 60 C 4 to 140 F option WTG or model USPA301 Unit mm inch Wall thickness probe for high temperature 0 to 200 C 32 to 392 F option WTH or model USPA302 Length Weight Wall thickness probe L m inch Weight kg lb WTG or USPA301 1 5 59 1 0 17 0 37 WTH or USPA302 1 5 59 1 0 24 0 53 ...

Reviews: