4-5.  Model and suffix code

Model 

Suffix 

Option Description 

code code code

SA11 

 

 

SENCOM Smart Adapter

Measuring 

-P1 

 

pH/ORP, conventional 

Parameter 

-P2 

 

pH/ORP, differential

 

-C1 

 

Specific conductivity (SC)

Type 

    -AA 

 

General purpose

Region 

       -N 

 

Not specified

Connection type        -VS 

 

 Variopin connector for SENCOM ID-chip in sensor

Style 

              -NN   

Always -NN

Option 

 

/UM 

Pipe and wall mounting hardware

4-6.  Spare part list

Order no. 

Product Name  

Quantity 

Remark

K1548PQ 

Universal mounting set 

1 set 

Option /UM

K1548GF 

O-ring set (5 pieces) 

1 set 

Option /UM contains Pipe and Wall mounting hardware

Figure 4.1 Positioning of O-ring

5.  Wiring and installation

Figure 5.1: Installation diagram SA11

5-1.  Installation site

The SA11 is weatherproof and can be installed both inside and outside. Select an 

installation site that meets the following conditions:

•  Mechanical vibrations and shocks are negligible

•  No relay switch and power switch are installed close to the device

•  There is space mounting the device to the Yokogawa- sensor & Yokogawa HOST system 

•  Not exposed to direct sunlight or severe weather conditions

•  Maintenance is possible

•  No corrosive atmosphere

•  Water Protection: IP67, NEMA Type 4X 

YPA Europe

Made in the Netherlands 3825HD-2

BA11

ACTIVE JUNCTION BOX

BUS

SENSOR CONNECTIONS

IN

OUT

J1

J2

J3

J4

WU11-M9-**-CN-S

Modbus Host

e.g. FLXA402

WU11-M9-**-WP-S

WU11-M9-**-WP-S

max. 100m (328ft)

max. 100m

(328ft)

max. 100m

(328ft)

Suffix

  -C-AA-M9

Serial#

  N3T400171

Power

  +2.7. +5.5VDC/30mW

T amb.

  -20.. + 55ºC

IP

 

Type 4X / IP66

2018

Read IM

12B06W03-01E-E

Modbus Slave 

SA11

Modbus Slave 

SA11

Summary of Contents for SA11

Page 1: ...IM 12A06S01 01EN P 2nd edition Start up Manual Model SA11 Smart Adapter...

Page 2: ...tices 6 2 7 SA11 fonts 6 3 CE marking products 7 3 1 Authorized Representative in EEA 7 3 2 Identification Tag 7 3 3 Users 7 4 Introduction and general description 7 4 1 Instrument check 7 4 2 Checkin...

Page 3: ...IM 01R01A01 01E Available for download The E or EN in the document number is the language code for English version the JA indicates the Japanese version and the Z indicates it is a multi language docu...

Page 4: ...anual WARNING This symbol indicates that an operator must follow the instructions laid out in this manual in order to avoid the risks for the human body of injury electric shock or fatalities The manu...

Page 5: ...od of typically 12 months from the date of shipment from the manufacturer Individual sales organizations can deviate from the typical warranty period and the conditions of sale relating to the origina...

Page 6: ...fonts c Copyright 2000 2001 efont The Electronic Font Open Laboratory All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that th...

Page 7: ...se SA11 with YOKOGAWA s HOST systems and sensors Please read carefully this manual and the instruction manual of the relevant HOST system and sensor before using this SA11 slave device 4 1 Instrument...

Page 8: ...cuits in which measures are taken to limit transient over voltages to an appropriately low level Note 2 Pollution degree indicates the degree of existence of solid liquid gas or other inclusions which...

Page 9: ...ram SA11 5 1 Installation site The SA11 is weatherproof and can be installed both inside and outside Select an installation site that meets the following conditions Mechanical vibrations and shocks ar...

Page 10: ...the SA11 on top of the YOKOGAWA labelled sensor or when the process conditions are higher than 100 C for power supply 2 7 to 4 5VDC or 125 C for power supply 4 5 to 5 5VDC an alternative mounting met...

Page 11: ...IB100 Interconnection in between the IB100 and SA11 is done using the WU11 type S interconnection cable with at both ends a M9 connector The wireless communication in between the Fieldmate system and...

Page 12: ...r s Manual If the system is configured incorrectly an error indicator may be displayed or the measurement values displayed may be incorrect Refer to the User Manual of the HOST system how to check the...

Reviews: