< 2. Installation and Wiring >
2-3
IM 19C1B3-01E
(2)
Pipe Mounting
When mounting the PUS400G on a pipe, install a pipe (2-inch, OD: 60.5 mm) in the vertical or
horizontal direction.
Figure 2.4 illustrates the installing procedure for the ultrasonic oscillator using pipe mounting bracket.
Pipe mounting bracket
2-inch pipe
Ultrasonic oscillator
Figure 2.4
Ultrasonic Oscillator as Mounted on Pipe
(3)
Wall Mounting
Figure 2.5 illustrates the installing procedure for the ultrasonic oscillator using wall mounting bracket.
Drill screw holes (for M8 screw, 3 places) in accordance with the figure below before mounting the
PUS400G.
27
±0.2
70
±0.2
Wall mounting bracket
Mounting screw (M8 3 pcs, customer’s scope)
Retaining screw (2 pcs attached)
M8 screw holes 3 pcs
Unit : mm
Figure 2.5
Hardware and Procedure for Wall Mounting