IM 77C01C01-01E

1st Edition : March 5.2001-00

Setting range

Rated

power

100W

200W

300W

400W

500W

600W

800W

1000W

1500W

2000W

3000W

4000W

5.556 

×

 10

-6

 to 1.000 

×

 10

-1

kWh/pulse

6.667 

×

 10

-6

 to 1.000 

×

 10

-1

kWh/pulse

1.000 

×

 10

-5

 to 1.000 

×

 10

-1

kWh/pulse

1.334 

×

 10

-5

 to 1.000 

×

 10

-1

kWh/pulse

2.000 

×

 10

-5

 to 1.000 

×

 10

-1

kWh/pulse

2.667 

×

 10

-5

 to 1.000 

×

 10

-1

kWh/pulse

(Note) When power OFF, integrated power on display is

maintained.  As for integrated pulse output, error of
less than 1 pulse of integrated power arises.

Integrated pulse ON pulse width: Indicates ON time of pulse to

output.  It can be set on parameter setting screen.
Set it so as not to exceed maximum ON pulse
widthe obtained by the formula below:

Maximum On pulse width (ms)

 =   pulse unit [kWh/pulse] x 3600 x 1000

2  

 

-10

                    rated power [W] x 1.2

Setting range

Remarks

10 to 1270ms Set at 10ms unit

Initial value if not specified

50ms

Communication Output specs.

Output point:1 point (Commonly use for RS-485 and LON

communications)

Function:Refer “Communication Output”

Standard Performance

Accuracy rating:

Instantanous power, voltage r.m.s. value,

current r.m.s. value 

±

0.5% of rated value (at

23

°

C

±

2

°

C)

(Equivalent JIS C 1102 0.5 grade)
Integrated power energy

±

(Power measuring a0.5% of rdg) (at

23

°

C

±

2

°

C)

Power factor

±

2% of rated value (at 23

°

C

±

2

°

C)

Analog output

±

0.5% of span (at 23

°

C

±

2

°

C)

(Equivalent JIS C 1111 0.5 grade)
However, 

±

1% of span in case span is 50 to 80%

of rated power.

Optional integrationg function: This function integrates power

energy during the time optional integration starts
to operate and display it by digital.  There are 2
methods to control optional integration, one is
made through optional integrating control signal
and the other is made through communication.
When optional integration control is made through
commuication, optional integrationg control signal
thereafter becomes invalid.  Therefore, make
control through either one of the above 2 methods.
When optional integration changes over from stop
to start, integration starts after optional integrated
power is reset.

Backup when power off (power meter): Integrated power holds

last integrated value when power off.  Optional
integration has not this function.

Response speed of instantanous power (analog output): Within

1 second (until enter into 

±

1% of last value)

Up date of transmit data: Power, voltage, current, power factor

within 500ms

Insulation resistance: 100M

 (500V DC) between any two

points of voltage input, current input, optional
integrated control signal, output, communication
output, power supply and ground

Withstand voltage: 2000V AC/minute between any two points

of voltage input, current input, output, power
supply and ground 2000V AC/minute between
communication output and (input, power supply)
1000V AC/minute between communication output
and (output, ground).
500V AC/minute between optional integrated
control signal and (input, output, communication
output, power supply and ground)

Impulse withstand voltage: 5kV (1.2/50

µ

s) between input and

output, input and ground, power supply and
ground

Temperature range: -10 to 55

°

C

Humidity range: 5 to 90% RH (no condensation)
Effect of power supply voltage fluctuation: 

±

0.3% of RV

(instantanous value)/85 to 264V AC

±

1.0% of RV (power factor)/85 to 264V AC

Effect of temperature change: 

±

0.5% of RV (instantanous

value)10

°

C

±

2.0% of RV (power factor)/10

°

C

Effect of input frequency: 

±

0.3% of RV (instantanous value)/45

to 65Hz

±

1.0% of RV (power factor)/45 to 65Hz

(RV=Rated Value)

Power voltatge: 85 to 264V AC, 45 to 65Hz
Power dissipation: 6VA (at 100V AC)

8VA (at 200V AC)

Display Operation

PT ratio CT ratio:

Setting of PT and CT ratio makes display
converting input of this instrument into primary
side input value of PT and CT.
Setting can be done on parameter setting  screen.

PT ratio setting range

CT ratio setting range

1 to 32000

0.05 to 32000

 Integrated power:

䊐䊐䊐䊐䊐

[kWh] or 

䊐䊐䊐䊐䊐

[MWh]

 (w/o symbol, partially fixed decimal point integer
5 digits)

Input power rating 

x PT ratio x CT ratio

30W to 99999kW

100kW to 999.99kW

1MW to 9.9999MW

10MW over

Display, decimal point

0 to 99999kWh

0.00 to 999.99MWh (kWh+10

3

)

0.0 to 9999.9MWh (kWh+10

3

)

0 to 99999kWh (kWh+10

3

)

Inregrated power data is reset to zero when the data exceed

maximunm display value.

Summary of Contents for Powercert PR201

Page 1: ...User s Manual IM 77C01C01 01E Model PR201 Power Monitor IM 77C01C01 01E 1st Edition ...

Page 2: ...Blank Page ...

Page 3: ...ounding 3 Turn off the product before installation and wiring 4 Use the power supply within specifications 5 Observe the following instructions for correct installation Recommended panel thickness is 1 to 10mm Install the product horizontally Install the product using attached fixture from the backside of the product Turn the screw only up to 180 after the screw touches the mounting panel to preve...

Page 4: ...ut 1 2 110V can also be used at 120V input Note 3 Rated input 5 6 440V is the specs only for 1 phase 2 wire system and 3 phase 3 wire system Note 4 Rated input A to F is the specs for only 3 phase 4 wire system Rated input voltage indicates phase voltage A B 64V C D 127V E F 227V indicate 110V 3 220V 3 480V 3 respectively In case of 440V 3 input it can be used at E F 227V of rated input Note 5 Spe...

Page 5: ...mensions R S T kWh Wh W V A 106 103 COMM COS φ SET ENT 110 110 0 5 15 15 66 82 4 96 45 Panel Thickness 1 to 10 2 Bolt M5 45 45 45 9 Screw M3 10 Screw M4 4 Screw M4 Short Bar When short ciruit end terminal ON Unit mm Panel Cut Dimension Minimum130 45 0 3 45 0 3 45 0 3 45 0 3 Minimum 117 φ101 Hole 2 φ6 Hole ...

Page 6: ...and bottom of the product as shown in the figure below then tighten the screws of the brackets Take care not to overtighten them Insert the product into the opening at the front of the panel Directionm to insert the product Terminal Arrangement 10 8 6 4 2 9 7 5 3 1 23 22 21 20 19 18 17 16 15 12 11 14 13 F05 EPS T14 EPS 1 phase 2 wire TML No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ...

Page 7: ...K L CT 1 K L CT 1 3 5 7 9 2 4 6 8 10 19 18 17 16 15 14 13 12 11 20 21 22 23 Voltage or Contact Power Side Load Side Power Supply Communication Shield Short Terminating R S T Receiver Device 3 phase 3 wire system 3 phase 4 wire system CAUTION The following caution for safety should be taken for handling of product We are not respon sible for damage incurred by use contrary to caution The following ...

Page 8: ...g items RS 485 station number data transmission rate lower limit of input range upper limit of input range PT ratio CT ratio in tegrating low cut power integrating pulse unit fixed point part exponent integrating pulse ON pulse duration 3 Adjustment items power momentary value in put zero power momentary value input span voltage momentary value input zero volt age momentary input span current mome...

Page 9: ...rated pulse unit characteristic setting 4 Integrated pulse ON width setting 4 RS 485 communication protocol setting 4 RS 485 station number setting 4 RS 485 data baud rate setting 4 LON communication node number setting 4 LON communication integrated power data transmission period setting minute 4 LON communication integrated power data transmission period setting second 4 LON communication power ...

Page 10: ...y 4 Change numeral column at pressing key 5 Change numeral column at pressing and key 6 Fixing numeral value at pressing key 7 Light on and off of setting value 8 If the setting is complete correctly press key If required correcting press any of key key and key then repeat from step 1 Example of Communication Connection RS232 C Converter RS232 C Cable Short circuit terminating 13 14 15 13 14 15 16...

Page 11: ...er W Integrated pulse output Function Outputs pulse in proportion to integrated power Output signal Open collector Output capacity 200mA 30V DC Integrated pulse unit Indicates actual kWh corresponding 1 pulse input to this instrument It can be set through integrated pulse unit characteristic and mantissa sections on parameter setting screen Input Output Specifications Input Specs Phase wire system...

Page 12: ...arts after optional integrated power is reset Backup when power off power meter Integrated power holds last integrated value when power off Optional integration has not this function Response speed of instantanous power analog output Within 1 second until enter into 1 of last value Up date of transmit data Power voltage current power factor within 500ms Insulation resistance 100MΩ 500V DC between ...

Page 13: ...layed in data display Current display R S T Voltage display R S S T T R R S T 3 phase 4 wire system Range switch This switch is used for display line change over and for movement column position of setting data and decimal point position Numeric up switch This switch is used for increment of setting parameter and input output adjustment data Numeric down switch This switch is used for decrement of...

Page 14: ... made noise or erroneous data would be ingnored Make time out disposal through upper computer Set time out time more than 1 second LON Communication Function Measuring data can be simply read out on personal computer through LON communication adapter and DDE server without consciousness of communication Also control of optional integration and initaialization of maximum and minimum values can be d...

Reviews: