Page 13 of 51
IM 60A02S01-01E-A
•
Certificate No. 4000798
•
Conforms to: FM 3600, FM 3610, FMRC 3611, FM 3615, FM 3616, UL 913, UL
1203, UL 60079-0, UL 60079-11
• Explosionproof/Dust-Ignition-Proof for:
- Class I, II, III; Groups A -G; Divisions 1 & 2.
- Class I, Zone 1, Group IIC T4.
- Tamb. –40°C to 80°C
• Intrinsically Safe for:
- Class I, Division 1, II, III; Groups A -G; Divisions 1 & 2.
- Zone 20, Class I, Zone 0
- AEx ia IIC T4
- Tamb. –40°C to 80°C
• Non-Incendive for:
- Class I, II, III; Groups A - D, F, G; Divisions 2.
- Class I, Zone 2, Group IIC T4.
- Tamb. –40°C to 80°C
• Enclosure rating: NEMA 4X.
• Temperature Class: T4
• Ambient Temperature: –40°C to 80°C
Note 2. Entity Parameters
• Intrinsically Safe Apparatus Parameters
[Groups A - G]
Ui = 28 V Ci = 0 pF
Ii = 115 mA Li = 0 µH
Pi = 0.65 W
•
Non-Incendive Apparatus Parameters
[Groups A – D, F, G]
Ui = 30 V
Ii = 150 mA
Pi = 0.85 W
Note 3. Wiring
• All wiring shall comply with National Electrical Code ANSI/NEPA70 and Local
Electrical Codes.
• For an ambient temperature ≥70°C, heat resistant cables shall be used with a
rating of at least 20°C above the ambient temperature.
• In hazardous location, wiring shall be in conduit.
WARNING: A SEAL SHALL BE INSTALLED WITHIN 50 cm OF THE
ENCLOSURE.
When installed in Division 2,“FACTORY SEALED, CONDUIT SEAL NOT
REQUIRED”.
Note 4. Installation
•
Installation should be in accordance with ANSI/ISA RP12.6 “Installation of
Intrinsically Safe Systems for Hazardous (Classified) Locations” and the
National Electric Code (ANSI/NFPA 70).