9.  SAFETY AND EMC STANDARDS

The following will be acquired.

Safety:

IEC/EN 61010-1 compliance (CE)

IEC/EN 61010-2-030 compliance (CE)

CAN/CSA-C22.2 No.61010-1 (CSA)

CAN/CSA-C22.2 No.61010-2-030 (CSA)

UL61010-1 (CSA NRTL/C)

UL61010-2-030 (CSA NRTL/C)

Overvoltage category: II

Pollution degree: 2

Measurement category: O (other)

Rated power voltage:  15-30 V DC (±10%) 2.5 W or 

 

100-240V AC/DC (±10%) 50/60 Hz 

2.6 W 6.7 VA

Rated voltage (Input signal) : ±0.15 V DC

Rated voltage (Analog output signal):  −10 to +10 V DC, 

 

0 to 20 mA DC

Rated voltage (Alarm output signal) : 30 V DC  1A

Rated voltage (Communication output signal) : 5 V DC

Rated transient overvoltage: 1500 V (*)

* This is a reference safety standard value for the 

measurement Category O. This value is not necessarily 

a guarantee of instrument performance.

 CAUTION

This instrument is for Measurement Category O 

(other). Do not use it for measurements in locations 

falling under Measurement Categories II, III, and IV.

    

Internal Wiring

Outlet

Entrance 

Cable

III

T

O

II

IV

Measurement 

category

Description

Remarks

O

(other) For measurements 

performed on circuits not 

directly connected to MAINS.

II

CAT.II For measurements 

performed on circuits directly 

connected to the low-voltage 

installation.

Appliances, 

portable 

equipments, 

etc.

III

CAT.III For measurements 

performed in the building 

installation.

Distribution 

board, circuit 

breaker, etc.

IV

CAT.IV For measurements 

performed at the source of 

the low-voltage installation.

Overhead 

wire, cable 

systems, etc.

EMC standards:

• CE:

EN 61326-1 Class A, Table 2

EN 61326-2-3

* The instrument continues to operate at a measurement 

accuracy of within ±20% of the range during testing.

EN 55011 Class A, Group 1

EN 61000-3-2

EN 61000-3-3

• RCM: 

EN 55011 Class A, Group 1

KC:

Electromagnetic wave interference prevention standard, 

electromagnetic wave protection standard

 CAUTION

Caution to comply with EMC standards: When 

operating this instrument by external power supply, 

use an independent power unit conforming to CE-

marking. Be sure to use the lightning arrester to 

comply EMC standards.

Note: When option code /C0 or /FB is specified, the conformity to 

the safety and EMC standards is excluded.

10.  ENVIRONMENT STANDARD

  RoHS Directive: EN 50581

  (However, when option code /C0 or /FB is specified, CE mark

-

ing is not applicable because the product does not comply 

with the Safety and EMC standards.)

11.  TRANSPORT AND STORAGE CONDITIONS

 •

Temperature: -25 to 70°C

 •

Temperature change rate: 20°C per hour or less

 •

Humidity: 5 to 95%RH (no condensation)

 CAUTION

Keep this product in a conductive bag when plugged 

out, during transport or storage.

6

IM 77J01U07-01E 10th Edition

Summary of Contents for Juxta VJU7

Page 1: ...TIONARY NOTES FOR SAFE USE OF THE PRODUCT This User s Manual should be carefully read before installing and operating the product Please keep this User s Manual for future reference For more information of the safety precautions please refer to the Precautions on the Use of the JUXTA Series IM 77J01A00 91Z1 The related manuals and general specifications are shown in the table below Doc Name Doc Nu...

Page 2: ...ing or damage Before turning on the power ensure the following Power supply voltage and input signal value applied to the product should meet the required specifications The external wiring to the terminals and wiring to ground are as specifications Wiring should be connected to the terminals on the socket of the product The terminals for external connections are of M3 screws Use crimp on terminal...

Page 3: ...7 select the RTD type to use in D09 RTD TYPE Furthermore for thermocouple or RTD input select the temperature unit in D21 UNIT 5 1 2 Input Range Set the 0 value of input range in D24 INPUT1 L_RNG and the 100 value of input range in D25 INPUT1 H_RNG numerically within the following specified range Input type TC Measurable range C JIS C 1602 IEC 60584 1 ITS 90 TYPE K 270 to 1372 JIS C 1602 IEC 60584...

Page 4: ... delay time from the establishment of return to normal conditions to its output Setting range 0 to 999 seconds Setting resolution 1 second However about 0 2 second is to be added to the set time to prevent wrong operation For example when an alarm ON delay is set to 1 second alarm output is generated if alarm status continues for 1 second or more after the input value exceeds the alarm setpoint Fu...

Page 5: ...n adjustment of output 2 P60 SELF CHK Self check result Q TEST Test 2 Q01 RJC ON OFF of RJC Q04 OUT1 TEST Forced output output 1 Q05 OUT2 TEST Forced output output 2 Q10 ALM1 TEST Forced output alarm 1 Q11 ALM2 TEST Forced output alarm 2 Q60 SELF CHK Self check result 1 The Status is displayed for service personnel to see history records 2 There are items not displayed depending on what input sens...

Page 6: ...llation Appliances portable equipments etc III CAT III For measurements performed in the building installation Distribution board circuit breaker etc IV CAT IV For measurements performed at the source of the low voltage installation Overhead wire cable systems etc EMC standards CE EN 61326 1 Class A Table 2 EN 61326 2 3 The instrument continues to operate at a measurement accuracy of within 20 of ...

Reviews: