YOKOGAWA FX1000 Installation Manual Download Page 3

IM 04L21B01-03EN  page 3/4

•  Connecting to the Power Measurement Terminal (/PWR1, /PWR5)

Max. rated voltage: 300V, Max. rated current: 1 A (/PWR1) or 5 A (/PWR5), 

Measurement category: CAT II

CAUTION

l

  If you are not using a VT and a CT, do not ground the input circuit.

l

  If you are wiring through conduits (metal tubes designed for wiring), 

install the CT (current transformer) inside a panel.

l

  Wire the voltage input and the current input within the same circuit.

Single-phase two-wire system

P1

P2

1S

1L

Power supply

1

2

K

L

CT

Load

Fuse

k

l

VT

U

V

1L

1S

P1

P2

u

v

Single-phase three-wire system

For a single-phase three-wire system, connect wires to the terminal block as follows.

P1

P2

P3

1S

1L

3S

3L

u

u

v

v

Power supply

1

N

2

K

L

CT

K

L

CT

Load

Fuse

VT

k

l

k

l

1L

1S

2L

2S

P0

P2

P1

U

U

V

V

Three-phase three-wire system

P1

P2

P3

1S

1L

3S

3L

Power supply

1

2 3

K

L

CT

K

L

CT

Load

Fuse

VT

R

(A)

S

(B)

T

(C)

k

l

k

l

1L

1S

3L

3S

P1

P3

P2

U

U

V
V

u

u

v

v

Wiring the Power Supply

Make sure to follow the warnings below when wiring the power supply. Failure to do 

so may cause electric shock or damage to the instrument.

WARNING 

l

 

To prevent electric shock, ensure that the power supply is turned off.

l

 

To prevent fire, use 600 V PVC insulated wires (AWG20 to AWG16; 

temperature rating of 80°C or more) or wires or cables with equivalent 

or better performance.

l

  Make sure to earth ground the protective earth terminal through a 

grounding resistance of 100 Ω or less before you turn on the power.

l

 

Use crimp-on lugs (designed for 4 mm screws) with insulation 

sleeves to connect both the power cord and the protective ground.

l

  To prevent electric shock, be sure to close the transparent cover 

for the power supply wires.

l

  Provide a power switch (double-pole type) on the power supply 

line to separate the FX from the main power supply. Use labels 

to indicate that this switch is for cutting off the power supply to 

the FX and to indicate ON and OFF. This switch must be suitably 

located and easily reached.

Switch specifications

  Steady-state current rating: 1 A or more (other than /P1); 

3 A or more (/P1)

  Inrush current rating: 60 A or more (other than /P1); 70 A 

or more (/P1)

 

Use a switch that complies with IEC60947-1 and IEC60947-3.

l

 

Connect a fuse (between 2 A and 15 A) to the power supply line.

l

  Do not add a switch or fuse to the ground line.

Other than /P1

/P1

Terminal arrangement

Protective grounding cord

Power cord

Use a power supply that meets the following conditions:

Item

Condition (Other than /P1)

Condition (/P1)

Rated supply voltage

100 to 240 VAC

24 VDC/AC

Allowable power supply voltage range 90 to 264 VAC

21.6 to 26.4 VDC/AC

Rated power supply frequency

50/60 Hz

50/60 Hz (for AC)

Allowable power supply frequency range 50/60 Hz ± 2%

50/60 Hz ± 2% (for AC)

Maximum power consumption

35 VA (100 V), 45 VA (240 V)

18 VA (for DC), 30 VA (for AC)

Note

Do not use a supply voltage of 132 to 180 VAC, as this may have adverse effects on 

the measurement accuracy.

4.  Protection of Environment

Control of Pollution Caused by the Product

This is an explanation for the product based on “Control of pollution caused by 

Electronic Information Products” in the People’s Republic of China.

产品中有毒有害物质或元素的名称及含量

部件名称

有毒有害物质或元素

铅 (Pb)

汞 (Hg)

镉 (Cd)

六价铬
(Cr6+)

多溴联苯

(PBB)

多溴二苯醚

(PBDB)

显示器 (LCD)

N/A

N/A

N/A

印刷电路板

N/A

N/A

N/A

内部接线材料

N/A

N/A

N/A

外壳 / 机箱 塑料

N/A

N/A

N/A

金属

N/A

N/A

N/A

电源

N/A

N/A

N/A

操作键

N/A

N/A

N/A

标准附件 /
可选附件

用于端子的
螺丝

N/A

N/A

N/A

安装支架

N/A

N/A

N/A

CF 卡

N/A

N/A

N/A

SD 卡

N/A

N/A

N/A

分流电阻

N/A

N/A

N/A

:  表示该部件的所有均质材料中的有毒有害物质或元素的含量均低于 GB/T 26752 标准所规

定的限量要求。

N/A

:表示该部件中至少有一种均质材料中的有毒有害物质或元素的含量超过 GB/T 26752 标准

所规定的限量要求。

本产品的部分部件包含 RoHS 指令中的限用物质,但是其使用方法不受该指令限制。

Some parts of this product include the restricted substances of RoHS Directive, but their 

applications are under the exemption of the directive.

环保使用期限

该标志为环境保护使用期限,根据 SJ/T11364,适用于在中国 ( 台湾、香港、

澳门除外 ) 销售的电子电气产品。
只要您遵守该产品相关的安全及使用注意事项,在自制造日起算的年限内,则
不会因产品中有害物质泄漏或突发变异,而造成对环境的污染或对人体及财产
产生恶劣影响

注)该年数为“环保使用期限”,并非产品的质量保证期。零件更换的推荐周期,请参照使用说明书

n

 

How to Dispose the Batteries

This is an explanation about the new EU Battery Directive (DIRECTIVE 2006/66/

EC). This directive is only valid in the EU.

Batteries are included in this product. Batteries incorporated into this product cannot 

be removed by yourself. Dispose them together with this product. When you dispose 

this product in the EU, contact your local Yokogawa Europe B.V.office. Do not 

dispose them as domestic household waste.

Battery type: Lithium battery

Notice:   The symbol (see above) means they shall be sorted out and collected as ordained in  

ANNEX II in DIRECTIVE 2006/66/EC.

Installing the DAQSTANDARD

To install the DAQSTANDARD, an appropriate license number (117-00000-5819) 

needs to be entered. 

1.  Start Windows.  Log onto Windows as an administrator.

2.  Double-click the downloaded file to extract the files.

3.  Double-click Install.exe.

4.  The installation program starts automatically.  Follow the instructions on the 

screen to proceed with the installation.

The table below indicates what languages the user’s manuals and software are 

installed in.

Language 

Selected at Time 

of Installation

Viewer

Hardware Configurator

Software

User's 

manual

Software

User's 

manual

English

English

English

English

English

German

German

English

German

English

French

French

English

French

English

Italian

Italian

English

Italian

English

Spanish

Spanish

English

Spanish

English

Portuguese

Portuguese

English

Portuguese

English

Russian

Russian

English

Russian

English

Korean

Korean

English

Korean

English

Japanese

Japanese

Japanese

Japanese

Japanese

Chinese

Chinese

Chinese

Chinese

Chinese

Note

•  Before installing the software, check that your PC is not infected by a virus.

•  Before starting installation, make sure that all the resident programs are exited.

•  To re-install the software, first uninstall it, then re-install it.

The DAQSTANDARD user’s manual is installed with DAQSTANDARD. To view it, 

on the Help menu, click User’s Manual. Or, from the Start menu, select [Programs] - 

[DAQSTANDARD]. You can view the user’s manual on Adobe Reader versions 7.0 

and later.

System Requirements

OS

Windows 7

Home Premium, SP1 32-bit and 64-bit editions
Professional, SP1 32-bit and 64-bit editions

Windows 8.1

32-bit and 64-bit editions (Supports the 

desktop mode)
Pro 32-bit and 64-bit editions (Supports the 

desktop mode)

Windows 10

Home (32-bit, 64-bit editions)
Pro (32-bit, 64-bit editions)

CPU and 

Main 

Memory

Pentium  4,  3  GHz  or  faster  Intel  x64  or  x86  processor;  2  GB  or 

more of memory

Hard Disk

A free space of 100 MB or more (more space may be required, 

depending on the amount of data stored).

Mouse

A mouse supported by the OS.

Keyboard

A keyboard supported by the OS.

Monitor

A video card that is recommended for the OS and a display that is 

supported by the OS, has a resolution of 1024×768 or higher, and 

that can show 65,536 colors (16-bit, high color) or more.

Interface 

Port

When communicating through RS-232, use a COM port (COM1, 

COM2, COM3, or COM4) supported by Windows. 
When communicating through RS-422/RS-485, connect a converter 

to an RS-232 port.
To communicate through an Ethernet connection, you need an 

Ethernet card supported by Windows. Also, the TCP/IP protocol 

must be installed.

Printer

A printer supported by Windows is required. An appropriate printer 

driver is also required.

User’s

Manual

IM 04L21B01-03EN

Installing 

the FXA120 DAQSTANDARD

About the Usage of Open Source Software

Heimdal

The DAQSTANDARD uses Heimdal source code.

In accordance with the Heimdal license agreement, the copyright notice, 

redistribution conditions, and license are listed below.

Copyright (c) 2006 Kungliga Tekniska Högskolan (Royal Institute of Technology, 

Stockholm, Sweden).All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are 

permitted provided that the following conditions are met:

1.  Redistributions of source code must retain the above copyright notice, this list of 

conditions and the following disclaimer.

2.  Redistributions in binary form must reproduce the above copyright notice, this 

list of conditions and the following disclaimer in the documentation and/or other 

materials provided with the distribution.

3.  Neither the name of the Institute nor the names of its contributors may be used 

to endorse or promote products derived from this software without specific prior 

written permission.

THIS SOFTWARE IS PROVIDED BY THE INSTITUTE AND CONTRIBUTORS “AS 

IS’’ AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT 

LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS

FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE 

INSTITUTE OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, 

INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES 

(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE 

GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS 

INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, 

WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING 

NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF 

THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Summary of Contents for FX1000

Page 1: ...ment Category II CAT II Measurement category II CAT II applies to measuring circuits connected to low voltage installation and electrical instruments supplied with power from fixed equipment such as electric switchboards This instrument is an EN61326 1 EMC standard class A instrument for use in commercial industrial or business environments The influence rate judgment condition A in the immunity t...

Page 2: ...isolated RTD n Optional Terminal Wiring WARNING l To prevent electric shock while wiring make sure that the power supply is turned off l If a voltage of more than 30 VAC or 60 VDC is to be applied to the output terminals use ring tongue crimp on lugs with insulation sleeves on all terminals to prevent the signal cables from slipping out when the screws become loose Furthermore use double insulated...

Page 3: ...um battery Notice The symbol see above means they shall be sorted out and collected as ordained in ANNEX II in DIRECTIVE 2006 66 EC Installing the DAQSTANDARD To install the DAQSTANDARD an appropriate license number 117 00000 5819 needs to be entered 1 Start Windows Log onto Windows as an administrator 2 Double click the downloaded file to extract the files 3 Double click Install exe 4 The install...

Page 4: ...the measurement method Most settings can be changed when memory sampling is in progress Basic setting mode A mode for configuring basic settings such as the scan interval and the measured data save method You cannot switch to this mode when memory sampling is in progress Basic setting mode Operating environment Environment View Message Input Alarm Security Media save Batch Communication Service po...