YOKOGAWA FU20-FTS Instruction Manual Download Page 6


 

IM 12B06J03-05EN-P 
 
 
 

1.3 Warranty and Service  

Yokogawa products and parts are 
guaranteed free from defects in 
workmanship and material under normal 
use and service for a period of (typically) 
12 months from the date of shipment from 
the manufacturer. Individual sales 
organizations can deviate from the typical 
warranty period, and the conditions of 
sale relating to the original purchase order 
should be consulted. Damage caused by 
wear and tear, inadequate maintenance, 
corrosion, or by the effects of chemical 
processes are excluded from this warranty 
coverage. In the event of warranty claim, 
the defective goods should be sent 
(freight paid) to the Service Department of 
the relevant sales Organization for repair 
or replacement (at 

Yokogawa’s 

discretion).  

 

The following information must be 
included in the letter accompanying the 
returned goods:  

  Model Code and Serial Number.  

  Original Purchase Order and Date.  

  Length of time in service and description 

of the process.  

  Description of the fault and 

circumstances of the failure.  

  Process/environmental conditions that 

may be related to the failure of the 
sensor 

  Statement as to whether warranty or 

non-warranty service is requested.  

  Complete shipping and billing 

instructions for return of material, plus 
the name and phone number of a 
contact person that can be reached for 
further information. 

  Clean Statement  

   Returned goods that have been in 

contact with process fluids must be 
decontaminated and disinfected prior to 
shipment. Goods should carry a 
certificate to this effect, for the health 
and safety of our employees. Material 
Safety Data sheets must be included for 
all components of the process to which 
the sensor(options) have been exposed.  

 

1.4 Serial number

 

The Serial number is defined by nine (9) 
alphanumeric characters:  
X

1

X

2

   

 

Production location  

X

3

X

4

   

 

Year/Month code  

X

5

X

6

X

7

X

8

X

9

   

Tracking number  

 
Example:   

N3P600028 

 

Table 1: Production Year code 

Year 

Year 
code 

Year 

Year 
code 

2014  P 

2026 

2015  R 

2027 

2016  S 

2028 

2017  T 

2029 

2018  U 

2030 

2019  V 

2031 

2020  W 

2032 

2021  X 

2033 

2022  Y 

2034 

2023  Z 

2035 

2024  1 

2036 

2025  2 

2037 

 

Table 2: Production Month code 

Month 

Month code 

January 

February 

March 

April 

May 

June 

July 

August 

September 

October 

November 

December 

 
 
 
 
 
 
 
 
 

Summary of Contents for FU20-FTS

Page 1: ...IM 12B06J03 05EN P 1st edition Instruction Manual Model FU20 FTS MTS Differential pH ORP sensor...

Page 2: ...oole E Todos los manuales de instrucciones para los productos antiexplosivos de ATEX est n disponibles en ingl s Si desea solicitar las instrucciones de estos art culos antiexplosivos en su idioma loc...

Page 3: ...com a delega o mais pr xima ou com um representante da Yokogawa PL Wszystkie instrukcje obs ugi dla urz dze w wykonaniu przeciwwybuchowym Ex zgodnych z wymaganiami ATEX dost pne s w j zyku angielskim...

Page 4: ...cations 8 2 9 Regulatory standards 9 3 INSTALLATION OF 21 FU20 FTS MTS 21 3 1 Typical installation 21 3 2 Preparing the sensor for use 21 3 3 Mounting the sensor 21 3 4 Mounting FU20 FTS MTS using qui...

Page 5: ...FU20 FTS MTS comes with a multipole VP connector and requires separate cable type WU10 V D or WE10 H D that are available in several lengths Additionally the models type VP and VS can be mounted in al...

Page 6: ...cess environmental conditions that may be related to the failure of the sensor Statement as to whether warranty or non warranty service is requested Complete shipping and billing instructions for retu...

Page 7: ...a 2 of theoretical value Note The temperature sensor included in the FU20 FTS MTS is designed for process compensation and for indication It is NOT designed for process temperature control 2 4 Dynamic...

Page 8: ...L x W x H 300 x 100 x 75 mm 11 8 x 3 9 x 3 0 inch Package weight max 0 33 kg 0 73 lbs 2 7 Environmental conditions Storage temperature 10 to 50 C 14 to 122 F Ingress Protection IP67 conform IEC 60529...

Page 9: ...e maximum process pressure LVD Directive 2014 35 EU Applying standards NEN EN IEC 61010 1 ANSI ISA 61010 1 CAN CSA C22 2 No 61010 1 Note 1 Models without ID chip with fixed cable or VP type I O signal...

Page 10: ...ame certificate number is created with a new issue number ATEX DEKRA11ATEX0014 X issue 1 effective from 03 2011 DEKRA11ATEX0014 X issue 2 effective from 02 2021 IECEx IECEx DEK 11 0064X issue 0 effect...

Page 11: ...rameters Ui 18 V Ii 170 mA Pi 0 4 W Li 0 1 mH models with fixed cable or Li 0 mH VS VP type Ci 150 nF models with fixed cable or Ci 0 4 nF VS type or Ci 0 nF VP type Ambient temperature 40 C to 40 C f...

Page 12: ...12 IM 12B06J03 05EN P Control drawing D E 2020 023 A50 part 1...

Page 13: ...Option Codes FU20 ab cd efg h ab Connection type Two alphanumeric characters identifying the length of the permanent cable each character from 0 to 9 VP Connector without ID chip VS Connector with ID...

Page 14: ...14 IM 12B06J03 05EN P Control drawing D E 2020 023 A50 part 2 SA11 P2...

Page 15: ...uired isolation 5 Sensor Model code Table 4 Model Suffix Codes Option Codes FU20 ab cd efg h ab Connection type VS Connector with ID chip cd Temperature sensor Region T1 Pt1000 IS for ATEX IECEx FM US...

Page 16: ...8V Ii 170 mA Pi 0 4 W Li 0 1 mH models with fixed cable or Li 0 mH VS VP type Ci 150 nF models with fixed cable or Ci 0 4 nF VS type or Ci 0 nF VP type Ambient temperature 40 C to 40 C for temperature...

Page 17: ...17 IM 12B06J03 05EN P Control drawing D E 2020 023 A51 part 1...

Page 18: ...ID chip cd Temperature sensor Region T1 Pt1000 IS for ATEX IECEx FM US FM CAN efg Type FTS PVDF body Tapered Thread Dome shaped Sodium ions sensitive membrane Silicon Viton sealings MTS PVDF body Tape...

Page 19: ...19 IM 12B06J03 05EN P Control drawing D E 2020 023 A51 part 2 SA11 P2...

Page 20: ...d Temperature sensor Region T1 Pt1000 IS for ATEX IECEx FM US FM CAN efg Type FTS PVDF body Tapered Thread Dome shaped Sodium ions sensitive membrane Silicon Viton sealings MTS PVDF body Tapered Threa...

Page 21: ...tal plane to eliminate air bubbles in the pH glass bulb see Figure 3 Figure 3 Sensor installation 3 2 Preparing the sensor for use Remove the sensor from its shipping box and slide of the so called we...

Page 22: ...n the process connection Tighten the adapter using a wrench on the adapter flats 3 Apply Teflon tape to the appropriate threaded end of the sensor 4 Place the O ring and screw the mating part of the a...

Page 23: ...Do not undo the part in the metal tube 5 Lead the sensor cable through the tube of the fitting from the side where the knurled knob has been removed Attach the sensor and cable as usual 6 Hold the se...

Page 24: ...2B06J03 05EN P Figure 7 Installation examples for the FU20 Fitting O ring Adapter FPS FU20 O ring FU20 FD40 Cleaning solution water acid etc K1547PH K1547PF 60mm HCNF SPRAY CLEANER FU20 adapter Proces...

Page 25: ...N P 4 DIMENSIONS Dimensions in mm inches Figure 8 Dimensions FU20 FTS MTS Figure 9 Dimensions 1 FU20 FTS MTS adapter Stainless Steel Titanium and FU20 FTS MTS adapter for FF40 FS40 and FD40 fittings N...

Page 26: ...nnector layout Table 7 Figure 12 Connection diagram connector type Note Preferred connection cable is Yokogawa Model WU10 V D or Model WE10 Pin no Description VP type Description VS type A pH pH B Ref...

Page 27: ...just the pH reading in the pH analyzer to the value indicated on the bottle in this case 7 00 Go to solution 2 to do a 2 point calibration 4 Rinse sensor thoroughly with tap water 5 Immerse the sensor...

Page 28: ...ng the complete sensor with solution Some cleaning solutions will damage the model code sticker and connector which are placed on top of the sensor Only clean the measuring elements at the bottom side...

Page 29: ...t T1 T2 Pt1000 Pt100 n a for FTD and VS Model NPT FSM FTD FTS MTS Dome shape model heavy duty Flat surface model self cleaning Dome shape model chemical resistant Differential pH sensor Differential p...

Page 30: ...K1547PG Hastelloy nozzle and mounting set HCNF K1547PH Nylon tube 10 meter and tube mounting set for chemical cleaning system K1520BF Buffer solutions Buffer solution pH 4 7 9 pNa 0 500 ml each ionic...

Page 31: ...L COMPATIBILITY CHART Table 11 Note Information in this list is based on our general experience and literature data and given in good faith However Yokogawa is unable to accept responsibility for clai...

Page 32: ...32 IM 12B06J03 05EN P IM 12B06J03 05EN P Printed in The Netherlands 01 2101 Subject to change without notice Copyright...

Reviews: